Zodiac pH Perfect Owners Manual

Owners Manual and Warranty Information
Please read thoroughly before starting device
Contents
Your pH Perfect has been designed to maintain your pools pH at an ideal balance. Your pools pH balance is the most important component for water chemistry for your skin, eyes hair etc plus it also to keeps your sanitiser working at its most efficient. (consider using a Zodiac Chlor Perfect to work alongside your pH perfect for optimal efficiency)
The pH level is detected by the sensor and then as required corrective solution is injected into the pool water keeping it safe and healthy
1. Contents of this package
1.1 Identification of parts ........................................................................................................................... 1
1.2 The Control Panel ................................................................................................................................. 2
2. Installation
2.1 Recommendations ...............................................................................................................................3
2.2 Technical details ................................................................................................................................... 3
2.3 Installation Diagram ..............................................................................................................................4
2.4 Installation of the Sensor POD ...........................................................................................................5
3. Starting up and operating
3.1 Calibration procedure .......................................................................................................................... 7
Rule for injecting pH Perfect .............................................................................................................8
3.2
3.3 Adjusting the dosage depending on alkalinity ................................................................................9
4. Adjustments: “Settings” menu
4.1 “Settings” menu - Default parameters ...........................................................................................10
4.2 Language ...............................................................................................................................................10
4.3 Set point ................................................................................................................................................10
4.4 Type of dosage ...................................................................................................................................... 11
4.5 Alkalinity level .......................................................................................................................................11
4.6 “OFA” over-feed protection ................................................................................................................11
4.7 Detection that filtration is in progress ...........................................................................................12
4.8 Resetting the appliance .....................................................................................................................13
5. Care and maintenance of your pH Perfect
5.1 Changing the peristaltic pump tube ............................................................................................... 13
5.2 Winterising the pH Perfect ................................................................................................................ 13
6. Water quality ...............................................................................................................................................14
7. Alarms ...........................................................................................................................................................14
8. Problem solving ..........................................................................................................................................15
9. Warranty .......................................................................................................................................................16
10. Online registration .................................................................................................................................... 17
1. Contents of this Package
The symbol indicates important information that must imperatively be taken into
account in order to avoid risk of injury to persons or damage to the appliance.
The
symbol indicates useful information.
1.1 Identification of parts
1. Control box
2. Mounting bracket and screws
3. Hole saw
4. Tubing
5. POD assembly
6. POD locking ring
7. pH sensor
8. pH sensor cable
9. Sensor calibration fluid
10. Anti Fume Cap 5lt and 15/20lt
6
1
4
8
7
3
5
2
10
9
1
1.2 The Control Panel
Blue Backlighted LCD 1 line 16 white character screen. Left side warning zone (alarms) / Right side pH display
Peristaltic pump
Connection for injection tube.
Connection for suction tube
BNC socket for connecting the pH sensor: The sensor cable is connected to the regulator unit with this connector
Master switch: for powering the control unit
Navigation button “ ” for navigating in the menu
SET/Esc” button: button for exiting from the menu; also for displaying the pH set point when pressed continuously
Navigation button “ ” for navigating in the menu
“CAL/Enter” button: button for enabling the sensor calibration mode (the button must be pressed for 5 seconds). This is also used for accepting changes in the menu
2
2. Installation
2.1 Recommendations
Warning: pH Perfect must be installed by an experienced pool professional.
Before carrying out any installation or maintenance of the pH Perfect control centre, disconnect it
from the mains power supplies.
Before starting to install the pH Perfect, check that you have all the components listed above and
ensure you read this instruction manual carefully.
This appliance is not intended for use by persons (including children) that lack experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a responsible person. Children should be supervised to ensure that they do not play with the device. The installation of this device should be carried out by a qualified person in accordance with the
Australian wiring rules AS/NZS 3000. The control centre should be located in the correct pool zone and connected to supply via a power
outlet that is protected by a residual current device (RCD) having a rated residual operating current
not exceeding 30mA. The power outlet should have a degree of protection suitable for the pool zone Ensure that equipotential bonding of all parts of the pool installation is carried out. During the installation phase of the pH Perfect, check the following:
• that the voltage of the power supply corresponds to the voltage indicated on the side of the appliance
• that the injection point pressure is lower than 1.5 Bar
• that the peristaltic pump's protection cover is correctly fitted
• that the suction tube is immersed in the corrective solution (pH up or down) container with the suction tube also connected to the peristaltic pump (left side).
• that the injection tube is connected on one side to the peristaltic pump (right side) and on the other side to the pool return pipe via the injection valve.
Zodiac Group Australia Pty Ltd will not be held liable for the use of this device with inappropriate
products.
The pH sensor is fragile, it must be handled with care. Try to avoid touching the tip with your fingers.
If the supply cord is damaged, it shall be replaced by the manufacturer or its service agent, or similarly qualified person in order to avoid a hazard.
2.2 Technical details
Dimension (L - W - H) 240 x 200 x 90mm Weight (appliance, sensor, tube and pipes) 1.7 kg Power feed 50Hz 220-240 V AC/50 Hz Consumption 12W Pump flow rate 1.5 l/hr Maximum back pressure 1.5 bar pH control range 0.0 pH-14.0 pH Appliance accuracy +/- 0.1 pH Calibration of the sensor 7.5 pH
3
2.3 Installation Diagram
Installation of the pH Perfect on the filtration system:
It is recommended that pH Perfect be installed after the filter (and any heating device) but before the salt chlorinator cell... if no salt chlorinator is installed it should be the last device on the return line
Hydraulic Diagram
Electrical connection
If you are using an external timer to control your filter pump please plug the ‘piggyback’ plug located on the pH Perfect into the timer and then plug the filter pump into the piggyback plug. This will create a controlled time circuit for pH Perfect with the filter pump.
Now connect the pH Perfect power plug into a power point to power the unit up
Your pH sensor is a very delicate product and can be affected by external forces such as stray electrical current from other devices.
When connecting the sensor into position try to keep the cable away from other power leads
The maximum pressure in the pipes must not be greater than 1.5 Bar. In order to extend the life of the peristaltic tube, the pressure should not exceed 1 bar
Install the pH Perfect control centre using the supplied fixing kit on a rigid support (a vertical wall) in an easy to access location.
Electrical Diagram
4
Warning:
- Acid fumes are highly corrosive
- Do not store acid directly underneath the control unit
- It is preferable to store acid in a safe place outside the filter shed
- If storing inside ensure adequate ventilation is provided
Loading...