Zircon HD900C User Manual

4 (1)
Zircon HD900C User Manual

EN MultiScanner® HD900c OneStep®

Multifunction Wall Scanner

The MultiScanner® HD900c, with advanced ColorTripdisplay, lights green in StudScan and DeepScan®, blue in Metal Scan, and red in AC Scan mode.

When AC WireWarning® is detected in StudScan, DeepScan®, or Metal Scan modes, screen will light, or flash, red.

StudScan: Locates the center and edges of wood and metal studs up to 34 in. (19 mm) deep

DeepScan®: Locates the center and edges of wood and metal studs up to 112 in. (38 mm) deep

Metal Scan: Detects ferrous (magnetic) metal (such as 12 inch rebar) up to 3 in. (76 mm) deep and non-ferrous (non-magnetic) metal up to 112 in. (38 mm) deep

AC Scan: Detects live unshielded AC wires up to 2 in. (51 mm) deep

1. INSTALLING THE BATTERY

Push in the battery door tab and open the door. Insert a new 9-volt alkaline battery, matching the positive (+) and negative (-) terminals and replace the door.

Low Battery Indicator: The Low Battery Indicator icon displays when the battery level is getting low. While the tool will still operate, the battery will need to be replaced soon. When the battery icon

to flash and is the only icon displayed on the screen, the battery level is too low and not sufficient to power the tool for proper operation. Please replace the 9-volt battery with a brand new battery immediately.

2. OPERATING TIPS

For optimum scanning results, it is important to properly hold the MultiScanner® HD900c and move slowly when scanning. The following tips will provide more accurate scanning results:

• Grasp the handle with your thumb on one side and your fingers on the other side. Make sure your fingertips are resting on

the handle and not touching the surface being scanned or the scanning head of the tool.

• Hold the tool straight up and down, parallel to the studs, and do not rotate the tool.

Keep tool flat against the wall and do not rock, tilt, or press hard when slowly sliding across the surface being scanned.

SpotLite® Pointer

 

Target Spotlight

ColorTripDisplay

 

Target Indication Bars

 

 

Auto Correcting

Signal Strength

Indication

 

Indicator

 

 

AC Icon

Edge /Center

Low Battery

Indicator

Metal Mode

Indicator

 

Indicator

 

StudScan /

 

DeepScan®

 

Mode Indicator

 

Power Button

Mode

Selector

 

 

Switch

Battery (Door Tab)

Avoid placing your other hand, or any other part of your body, on the surface being scanned. This will interfere with the tool’s performance.

If you’re receiving erratic scanning results, it may be a result of humidity, moisture within the wall cavity or drywall,

or recently applied paint or wallpaper that hasn’t fully dried. While the moisture may not always be visible, it will interfere with the tool’s sensors. Please allow a few days for the wall to dry out.

Depending on the proximity of electrical wiring or pipes to the wall surface, the scanner may detect them in the same manner as studs. Caution should always be used when nailing,

cutting, or drilling in walls, floors, and ceilings that may contain these items.

To avoid surprises, remember that studs or joists are normally spaced 16 or 24 in. (41 or 61 cm) apart and are 112 in. (38 mm) in width. Anything closer together or a different width may not be a stud, joist, or firebreak.

If display lights, or flashes, red in StudScan, DeepScan®, or Metal Scan, WireWarning® detection has indicated the presence of live AC electricity. Exercise extreme caution before nailing, cutting, or drilling.

Always turn off power when working near electrical wires.

SCANNING DIFFERENT SURFACES

Wallpaper: MultiScanner® HD900c functions normally on walls covered with wallpaper or fabric, unless the materials are metallic foil, contain metallic fibers, or are still wet after application.

Wallpaper may need to dry for several weeks after application.

Freshly painted walls: May take one week or longer to dry after application.

Lath & plaster: Due to irregularities in plaster thickness, it is difficult for MultiScanner® HD900c to locate studs in Stud modes. Change to Metal Scan mode to locate the nail heads holding wood lath to the studs. If the plaster has metal mesh

reinforcement, MultiScanner® HD900c may be unable to detect through that material.

Extremely textured walls or acoustic ceilings:

When scanning a ceiling or wall with an uneven surface, place thin cardboard on the surface to be scanned and scan over the cardboard in DeepScan® mode. If irregular scanning results are received, switch to Metal Scan mode to locate nails or drywall screws that line up vertically where a stud or joist is positioned.

Wood flooring, subflooring, or gypsum drywall over plywood sheathing:

Use DeepScan® mode and move the tool slowly. The Signal Strength Indicator may only display 1 or 2 bars when the tool locates a stud through thick surfaces.

MultiScanner® HD900c cannot scan for wood studs and joists through tile, concrete or carpet and padding. In problematic situations, try using Metal Scan to locate nails or screws that may line up vertically where a stud or joist is positioned.

Note: Sensing depth and accuracy can vary due to moisture, content of materials, wall texture, and paint. Indoor use only.

WARNING Do not rely exclusively on the detector to locate items behind the scanned surface. Use other information sources to help

locate items before penetrating the surface. Such additional sources include construction plans, visible points of entry of pipes and wiring into walls, such as in a basement, and in standard 16 and 24 in. (41 and 61 cm) stud spacing practices.

3. SELECTING THE MODE

Move selector switch to the desired mode. ColorTripdisplay will light green in StudScan for finding wood or metal studs; green in DeepScan® for scanning walls over 34 in. (19 mm) thick; blue in Metal Scan for locating metal; and red in AC Scan for locating live AC wiring.

Unit will remain off if Power button is not pressed.

4. TURNING ON/CALIBRATING THE TOOL

Place MultiScanner® HD900c against the wall before pressing the Power button in StudScan or DeepScan® mode.

Once powered on, tool will automatically perform all calibrations. The LCD will display all icons until calibration is complete. Upon completion of calibration, the SpotLite® Pointer and buzzer will momentarily activate and the tool will begin continuous measurements. Continue to hold the Power button down and keep the tool flat against the wall and begin scanning.

Note: It is important to wait for calibration to complete (1–2 seconds) before moving the scanner.

ACT(Auto Correcting Technology)

During scanning, the tool will

automatically recalibrate itself when needed. This recalibration is

transparent and no indication is made. If an arrow icon illuminates, the tool calibrated near or over a stud and then moved away. The arrow indicates the direction of the missed stud.

5. FINDING A STUD

Always scan for studs with the scanner placed flat against the wall. Move the mode switch to StudScan, place the tool flat against the wall, then press and hold the Power button. Wait for beep to

confirm calibration has completed before moving scanner. Display will light green with the word “StudScan” to indicate the mode.

Slowly slide tool across surface. EDGE indication will illuminate, indicating location of the stud edge.

Continue sliding tool. When the center of a stud

is located, the three bars on the Signal Strength Indicator, the middle segments of the Target Indication bars, CENTER indication, and SpotLite® Pointer will all illuminate and the buzzer will sound.

In cases of deeper studs (thicker walls), when the center of the stud is located, only two bars will show

on the Signal Strength Indicator and only the SpotLite®

Pointer and middle segments of the Target Indication Bars will illuminate. If you still cannot locate a stud,

try DeepScan® mode. Display will light green with the word “DeepScan” to indicate the mode.

Note: To determine if the object located was a wood stud, metal stud, or pipe, scan the location in Metal Scan mode. In Metal Scan, only the metal drywall screws will be found

in wood studs, while metal will be indicated throughout the entire metal stud or pipe. To better determine if the target object is a metal stud or pipe, studs usually run floor to ceiling whereas a pipe may not.

6. WIREWARNING® DETECTION

Zircon's WireWarning® detection feature works continuously in StudScan, DeepScan®, and Metal Scan modes. When live AC voltage is detected, the AC icon will appear

in the display and the display will light red until AC is no longer detected. If scanning begins directly over an area with live AC wire, the AC icon and display will flash red continuously. Use extreme caution under these circumstances or whenever live AC wiring is present.

WARNING Electrical field locators may not detect live AC wires if wires are more than 2 in. (51 mm) from the scanned surface, in

concrete, encased in conduit, present behind a plywood shear wall or metallic wall covering, or if moisture is present in the environment or scanned surface.

WARNING DO NOT ASSUME THERE ARE NO LIVE ELECTRICAL WIRES IN THE WALL. DO NOT TAKE ACTIONS THAT COULD BE DANGEROUS

IF THE WALL CONTAINS A LIVE ELECTRICAL WIRE. ALWAYS TURN OFF THE ELECTRICAL POWER, GAS, AND WATER SUPPLIES BEFORE PENETRATING A SURFACE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS INJURY OR PROPERTY DAMAGE.

Always turn off power when working near electrical wires.

7. SCANNING IN METAL MODE

1.Move mode switch to Metal Scan. Place tool flat on the wall, then press and hold the Power button. Wait for tool to beep to confirm calibration has completed. Display will light blue with the word “METAL” to indicate the mode.

2.(Figure A) While holding the Power button, slowly slide tool across the surface. Mark the location where you get the highest metal indication (the most Target Indication bars on the screen). If the signal is strong, the SpotLite® Pointer will also illuminate and a steady beep will sound. Continue in the same direction until the display bars reduce.

3.Without releasing Power button, reverse direction (back towards the previous mark) and mark the location where the display bars peak. The midpoint between the two marks is the approximate location of the center of the metal object.

INTERACTIVE CALIBRATION

Interactive calibration is the act of calibrating the tool closer to the target to reduce the tool’s sensitivity. In Metal Scan, you can perform interactive calibration to adjust the tool’s sensitivity to metal. This is ideal when your scan indicates metal over a large area. To refine your scanning area and narrow the location of the metal target, follow step 4 below.

4. (Figure B) To further pinpoint the location of the metal target, release the Power button. Place tool on the wall over one of your previous marked locations, calibrate, and scan the area again. This will reset the tool to a lower sensitivity and narrow the scan area. This procedure can be repeated multiple times to narrow the scan area even further (Figure C).

MAXIMUM SENSITIVITY

Unlike interactive calibration, maximum sensitivity is ideal when only an approximate location of metal needs to be determined. To achieve maximum sensitivity, calibrate the tool in the air, away from any obvious metal, by pressing and holding the Power button. Then follow steps 2 and 3 above. (Only Metal Scan mode can be calibrated off the wall to achieve maximum metal sensitivity.)

Figure A

Figure B

Figure C

8. SCANNING IN AC MODE

AC Scan will only detect live (hot), unshielded AC wiring. Please refer to the WARNING statement in number 6. WIREWARNING® DETECTION for more important details and warnings about AC detection.

1.Move mode switch to AC Scan. Press tool flat against the wall, then press and hold the Power button. Wait for the beep to confirm calibration has completed before moving the tool. Display will light red with the AC icon to indicate the mode.

2.(Figure A) While holding the Power button, slowly slide the tool across the surface. Mark the location where you get the highest AC indication (the most Target Indication bars on the screen). If it is a strong signal, the SpotLite® Pointer will also illuminate and a steady beep will sound. Continue in the same direction until the display

bars reduce.

3.Without releasing Power button, reverse direction (back towards the previous mark) and mark the location where the display bars peak. The midpoint between the two marks is the approximate location of the live AC wiring.

As with Metal Scan, you can perform interactive calibration in AC Scan to adjust the tool’s sensitivity to live AC. If your scan indicates live AC over a large area, you can refine the scanning area and narrow the location of the AC target by following step 4 below.

4. (Figure B) To further pinpoint the location of the live AC target, release the Power button. Place the tool on the wall over one of your previous marked locations, calibrate, and scan the area again. This will reset the tool to a lower sensitivity and narrow the scan area. This procedure can be repeated multiple times to narrow the scan area even further (Figure C).

If you directly calibrate over an area with live AC, the middle Target Indication bars and red screen will flash on and off. Release the Power button, slide the tool a few inches to the left or right, and begin your scan again.

FCC Part 15 Class B Registration Warning

This device complies with Part 15 of FCC Rules. Operations subject to the following two conditions:

(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

9. HELPFUL HINTS (See also number 2, Operating Tips)

Situation

Probable Cause

Solution

Detects other objects besides studs

• Electrical wiring and metal/plastic pipes may be

• Scan the area in Metal Scan and AC Scan to determine if metal or hot AC is present.

in StudScan mode.

near or touching back surface of wall.

• Check for other studs equally spaced to either side 12, 16, or 24 in. (31, 41, or 61 cm) apart or for the same stud

Finds more targets than there

 

at several places directly above or below the first scan area.

should be.

 

• A stud reading would measure approximately 112 in. (38 mm) apart from each edge; anything larger or smaller is

 

 

most likely not a stud if not near a door or window.

Area of voltage appears much larger

• Voltage detection can spread on drywall as much

• To narrow detection, turn unit off and on again at the edge of where wire was first detected and scan again.

than actual wire (AC only).

as 12 in. (31 cm) laterally from each side of an

 

 

actual electrical wire.

 

 

 

 

Difficulty detecting metal.

• Tool calibrated over metal object.

• The scanner may have been calibrated over a metal object, reducing sensitivity. Try calibrating in another location.

 

• Metal targets too deep or small.

• Scan in both horizontal and vertical directions. Metal sensitivity is increased when metal object is parallel to sensor,

 

 

located under Zircon logo.

 

 

 

Image of metal object appears wider

• Metal has greater density than wood.

• To reduce sensitivity, recalibrate MultiScanner® HD900c over either of first two marks (Metal mode only).

than actual size.

 

 

Constant readings of studs near

• Double and triple studs are usually found around

• Detect outer edges so you know where to begin.

windows and doors.

doors and windows. Solid headers are above them.

 

 

 

 

Display flashing red.

• Tool calibrated directly over an area where live

• Release Power button, slide tool a few inches to the left or right, and begin your scan again.

 

AC was detected.

 

You suspect electrical wires, but do not

• Wires are shielded by metal conduit, a braided

• Try Metal Scan mode to see if you can find metal, wire, or metal conduit.

detect any.

wire layer, metallic wall covering, plywood shear

• Use extra caution if the area has plywood, thick wood backing behind drywall, or thicker than normal walls.

 

wall, or other dense material.

• If a switch controls an outlet, make sure it is ON for detection, but turned off when working near

 

• Wires deeper than 2 in. (51 mm) from surface

electrical wires.

 

might not be detected.

Use CAUTION when nailing, sawing, or drilling into walls, floors, and ceilings where these items may exist.

 

• Wires may not be live.

 

 

 

 

 

Tool not operating.

• Battery level low for proper operation.

• Replace with brand new 9V alkaline battery.

Flashing Low Battery Indicator.

 

 

 

 

 

ACT, ColorTrip, DeepScan, MultiScanner, OneStep, SpotLite, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.

Visit www.zircon.com/support for the most current instructions.

LIMITED 1 YEAR WARRANTY

Return product freight prepaid with proof of purchase date (dated sales receipt) and $5.00 to cover postage

Zircon Corporation, (“Zircon”) warrants this product to be free from defects in materials and workmanship

and handling, to:

 

 

 

for one years from the date of purchase. Any in-warranty defective product returned to Zircon*, freight prepaid

Zircon Corporation

 

 

 

with proof of purchase date and $5.00 to cover postage and handling, will be repaired or replaced at Zircon’s

*Attn: Returns Department

 

 

 

option. This warranty is limited to the electronic circuitry and original case of the product and specifically

1580 Dell Avenue

 

 

 

excludes damage caused by abuse, unreasonable use or neglect. This warranty is in lieu of all other warranties,

Campbell, CA 900c08-6918 USA

 

 

 

express or implied, and no other representations or claims of any nature shall bind or obligate Zircon.

Be sure to include your name and return address. Out of warranty service and repair, where proof of purchase

Any implied warranties applicable to this product are limited to the one year period following its purchase.

is not provided, shall be returned with repairs charged C.O.D. Allow 4 to 6 weeks for delivery.

 

IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES

Customer Service, 1-800-245-9265 or 1-408-963-4550

 

 

 

RESULTING FROM POSSESSION, USE OR MALFUNCTION OF THIS PRODUCT.

 

 

 

Monday–Friday, 8:00 a.m. to 5:00 p.m. PDT

 

 

 

In accordance with government regulations, you are advised that: (i) some states do not allow limitations on

 

 

 

www.zircon.com • info@zircon.com

 

 

 

how long an implied warranty lasts and/or the exclusion or limitation of incidental or consequential damages,

 

 

ZirconCorporation

ZirconTV

so the above limitations and/or exclusions may not apply to you, and further (ii) this warranty gives you specific

 

 

 

 

ZirconTools | ZirconToolPro

ZirconTools

legal rights and you may also have other rights which vary from state to state.

© 2016 Zircon Corporation • P/N 68216 • Rev B 10/16

 

 

 

 

 

 

Loading...
+ 1 hidden pages