Zircon StudSensor Pro Owner's Manual

5 (1)
Zircon StudSensor Pro Owner's Manual

StudSensor/StudSensorPro

Stud Finder/Stud and Joist Finder

The Zircon StudSensorlocates wood and metal studs in walls. The StudSensorPro also locates studs in floors and ceilings. They feature a sleek, high-impact case and a built-in clip.

Use Stud Scan for depths up to 34 in. (19 mm) with 18 in. (3 mm) accuracy and DeepScan® (StudSensor Pro) for depths up to 112 in. (38 mm) with 316 in. (5 mm) accuracy.

FREE! Customer Support.

Visit www.zircon.com

Stud Edge Groove

Stud Scan Mode LED

Stud DeepScan® Mode LED (StudSensor Pro only)

TruCal® LED

On/Off Button

warranty gives you specific legal rights and you may also have other rights which vary from state to state. Return product freight prepaid with proof of purchase date (dated sales receipt) and $5.00 to cover postage and handling, to:

Zircon Corporation

*Attn: Returns Department

1600 Dell Avenue, Unit K

Campbell, CA 95008-6992 USA

Be sure to include your name and return address. Out of warranty service and repair, where proof of purchase is not provided, shall be returned with repairs charged C.O.D. Allow 4 to 6 weeks for delivery.

Customer Service: 1-800-245-9265 or 1-408-866-8600 E-mail: info@zircon.com

U.S. Patent 4464622, 5352974, 5619128, 6023159, 6291970, D455430, D455750 • Canada Patent 1106932 • G.B. Patent 2117909B, 2159630B ©2004 Zircon Corporation • P/N 58927 • Rev D 04/04

The Zircon StudSensorlocates wood and metal studs in walls. The StudSensorPro also locates studs in floors and ceilings. They feature a sleek, high-impact case and a built-in clip.

Use Stud Scan for depths up to 34 in. (19 mm) with 18 in. (3 mm) accuracy and DeepScan® (StudSensor Pro) for depths up to 112 in. (38 mm) with 316 in. (5 mm) accuracy.

FREE! Customer Support.

Visit www.zircon.com

Pro

and Joist Finder

Stud Edge Groove

Stud Scan Mode LED

Stud DeepScan® Mode LED (StudSensor Pro only)

TruCal® LED

On/Off Button

 

 

LIMITED 1 YEAR WARRANTY

warranty gives you specific legal rights and you may also have other rights

Zircon Corporation, (“Zircon”) warrants this product to be free from defects

which vary from state to state. Return product freight prepaid with proof of

in materials and workmanship for one year from the date of purchase. Any

purchase date (dated sales receipt) and $5.00 to cover postage and handling, to:

in-warranty defective product returned to Zircon*, freight prepaid with proof

Zircon Corporation

of purchase date and $5.00 to cover postage and handling, will be repaired

*Attn: Returns Department

or replaced at Zircon’s option. This warranty is limited to the electronic

1600 Dell Avenue, Unit K

circuitry and original case of the product and specifically excludes damage

Campbell, CA 95008-6992 USA

caused by abuse, unreasonable use or neglect. This warranty is in lieu of all

Be sure to include your name and return address. Out of warranty service and

other warranties, express or implied, and no other representations or claims

repair, where proof of purchase is not provided, shall be returned with repairs

of any nature shall bind or obligate Zircon. Any implied warranties applicable

charged C.O.D. Allow 4 to 6 weeks for delivery.

to this product are limited to the one year period following its purchase.

Customer Service: 1-800-245-9265 or 1-408-866-8600

IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR

E-mail: info@zircon.com

CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE OR

 

MALFUNCTION OF THIS PRODUCT.

 

In accordance with government regulations, you are advised that:(i) some

U.S. Patent 4464622, 5352974, 5619128, 6023159, 6291970, D455430,

states do not allow limitations on how long an implied warranty lasts and/or

D455750 • Canada Patent 1106932 • G.B. Patent 2117909B, 2159630B

the exclusion or limitation of incidental or consequential damages, so the

©2004 Zircon Corporation • P/N 58927 • Rev D 04/04

above limitations and/or exclusions may not apply to you, and further. (ii) this

 

 

NOTE: DO NOT LOOSEN OR REMOVE SCREW ON BACK OF THE UNIT.

1

Squeeze sides

 

of unit to help

release clip end.

Slide 9-V battery into compartment, terminal side first, matching

(-) terminals from battery to case.

AND SCANNING SCAN OR STUD

DEEPSCAN® MODES

With StudSensor turned off, position the

against the wall.

5Squeeze On/Off button and hold in. Press twice and hold for DeepScan®

mode (Pro only). Wait for the TruCal LED to light.

INSTALLING THE BATTERY

NOTE: DO NOT LOOSEN OR REMOVE SCREW ON BACK OF THE UNIT.

1

Squeeze sides

 

of unit to help

release clip end.

Slide 9-V battery into compartment, terminal side first, matching

(-) terminals from battery to case.

Replace the clip. Battery life is approximately 50 hours.

CALIBRATION AND SCANNING STUD SCAN OR STUD

DEEPSCAN® MODES

With StudSensor turned off, position the

flat against the wall.

5Squeeze On/Off button and hold in. Press twice and hold for DeepScan®

mode (Pro only). Wait for the TruCal LED to light.

6

In either mode turn

 

on and slowly slide

 

horizontally across

 

wall, right or left. As

 

begin to approach a

 

the red LEDs will

 

successively, from bottom to top.

7

When the top

green LED is lit the beep sounds, have located the

of the stud. this spot.

8marked spot until the LEDs go out. unit in reverse direction to locate edge of stud.

9Mark this second spot. Middle

is centered

the two marks.

VERIFYING IF THE UNIT WORKS

10

Turn StudSensor

 

on in the air. If

LEDs light when

you bring your hand up

to the back, then the unit is

working properly.

6

 

 

across

 

right or left. As

 

to approach a

 

the red LEDs will

 

from bottom to top.

7

When the top

green LED is lit beep sounds, located the

of the stud. this spot.

8Continue scanning beyond the marked spot until the LEDs go out.

unit in reverse direction to locate edge of stud.

9 Mark this second spot. Middle

is centered

the two marks.

VERIFYING IF THE UNIT WORKS

10 Turn StudSensor on in the air. If

the LEDs light when you bring your hand up

to the back, then the unit is working properly.

HELPFUL HINTS

Situation

Probable Causes

Solutions

 

 

 

No indications.

• No studs in that area.

• Move several inches to the left or right and start again.

 

• You are in DeepScan mode

 

 

and accidentally calibrated

 

 

over a stud.

 

 

 

 

Lights start

• Over-the-stud calibration

• Release On/Off button, move over a few inches, press

blinking and unit

error.

On/Off button, and start again.

beeps repeatedly.

• Scan began on dense part

• On rough surfaces, place piece of cardboard on wall,

 

of wall or over stud.

scanning through it to help slide unit more smoothly.

 

• Unit not flat against wall.

• Always hold StudSensor parallel to stud or joist and

 

• Unit was rocked or lifted

move across it.

 

during scan.

 

 

 

 

Indications in too

• Detects other objects

• Use CAUTION when nailing, cutting, or drilling in walls,

many places.

besides studs.

floors, and ceilings where these items may exist.

 

• Electrical wiring and metal/

• Because studs are normally spaced 16 in. (410 mm)

 

be near or

or 24 in. (610 mm) apart and are 112 in. (38 mm)

 

surface of wall.

wide, beware of anything closer together or of a

 

 

different width.

 

 

• Always turn off power when nailing, cutting, or drilling

 

 

near electrical wires.

OPERATING CAUTIONS

Depending on the proximity of electrical wiring or pipes to the wall surface, the StudSensor may detect them in the same manner as studs. Caution should always be used when nailing, cutting, or drilling in walls, floors, and ceilings that may contain these items.

To avoid surprises, remember that studs or joists are normally spaced 16 in. (410 mm) or 24 in. (610 mm) apart and are 112 in.

(38 mm) in width. Anything closer together or a different width may not be a stud, joist, or firebreak. Always turn off the power when working near electrical wires.

WORKING WITH DIFFERENT MATERIALS

The StudSensor and StudSensor Pro are designed for use on dry interior walls only. Three primary factors can affect sensing depth: thickness, density, and moisture content.

StudSensor and StudSensor Pro are not designed to scan materials with inconsistent density such as:

Ceramic floor tile

Carpeting and padding

Wallpaper with metallic fibers

Freshly painted walls that are still damp (must dry at least a week)

Lath and plaster

HELPFUL HINTS

 

Causes

Solutions

 

 

 

No indications.

• No studs in that area.

• Move several inches to the left or right and start again.

 

• You are in DeepScan mode

 

 

and accidentally calibrated

 

 

over a stud.

 

 

 

 

Lights start

• Over-the-stud calibration

• Release On/Off button, move over a few inches, press

blinking and unit

error.

On/Off button, and start again.

beeps repeatedly.

• Scan began on dense part

• On rough surfaces, place piece of cardboard on wall,

 

of wall or over stud.

scanning through it to help slide unit more smoothly.

 

• Unit not flat against wall.

• Always hold StudSensor parallel to stud or joist and

 

• Unit was rocked or lifted

move across it.

 

during scan.

 

 

 

 

Indications in too

• Detects other objects

• Use CAUTION when nailing, cutting, or drilling in walls,

many places.

besides studs.

floors, and ceilings where these items may exist.

 

• Electrical wiring and metal/

• Because studs are normally spaced 16 in. (410 mm)

 

plastic pipes may be near or

or 24 in. (610 mm) apart and are 112 in. (38 mm)

 

touching back surface of wall.

wide, beware of anything closer together or of a

 

 

different width.

 

 

• Always turn off power when nailing, cutting, or drilling

 

 

near electrical wires.

OPERATING CAUTIONS

Depending on the proximity of electrical wiring or pipes to the wall surface, the StudSensor may detect them in the same manner as studs. Caution should always be used when nailing, cutting, or drilling in walls, floors, and ceilings that may contain these items.

To avoid surprises, remember that studs or joists are normally spaced 16 in. (410 mm) or 24 in. (610 mm) apart and are 112 in.

(38 mm) in width. Anything closer together or a different width may not be a stud, joist, or firebreak. Always turn off the power when working near electrical wires.

WORKING WITH DIFFERENT MATERIALS

The StudSensor and StudSensor Pro are designed for use on dry interior walls only. Three primary factors can affect sensing depth: thickness, density, and moisture content.

StudSensor and StudSensor Pro are not designed to scan materials with inconsistent density such as:

Ceramic floor tile

Carpeting and padding

Wallpaper with metallic fibers

Freshly painted walls that are still damp (must dry at least a week)

Lath and plaster

Loading...
+ 1 hidden pages