Zenith ZW5000 Service Manual

0 (0)

www.zenithappliances.com

Room Air Conditioner

SERVICE MANUAL

MODELS: ZW5000

CAUTION

• BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.

• ONLY FOR AUTHORIZED SERVICE PERSONNEL.

Air Conditioner Service Manual

 

TABLE OF CONTENTS

 

Safety Precautions..........................................................................................................................................

3

Dimensions .....................................................................................................................................................

7

Outside Dimensions ...................................................................................................................................

7

Product Specifications ..................................................................................................................................

8

Installation .......................................................................................................................................................

9

Select the Best Location ...........................................................................................................................

9

How to Install..............................................................................................................................................

9

Installation Kits Content(Some Models) ...................................................................................................

10

How to Secure the Drain Pipe ..................................................................................................................

11

Operation ......................................................................................................................................................

12

Features ...................................................................................................................................................

12

Insulation Resistance Test........................................................................................................................

12

About the Controls on the Air conditioner ................................................................................................

12

Disassembly ..................................................................................................................................................

13

Mechanical Parts......................................................................................................................................

13

Air Handling Parts ....................................................................................................................................

14

Electrical Parts .........................................................................................................................................

15

Refrigerating Cycle...................................................................................................................................

16

Schematic Diagram.......................................................................................................................................

19

Wiring Diagram.........................................................................................................................................

19

Troubleshooting Guide .................................................................................................................................

20

Piping System ..........................................................................................................................................

20

Troubleshooting Guide .............................................................................................................................

21

Room Air Conditioner Voltage Limits........................................................................................................

23

Exploded View ..............................................................................................................................................

26

Replacement Parts List ................................................................................................................................

27

2 Room Air Conditioner

Zenith ZW5000 Service Manual

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

WARNING This symbol indicates the possibility of death or serious injury.

CAUTION This symbol indicates the possibility of injury or damage to property only.

■ Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

WARNING

Installation

Always install the expansion panel(s).

Do not place the power cord near a heater.

Improper assembly or installation may cause incorrect operation, including injury, fire, and electric shock hazards.

Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc.

• It may cause explosion or fire.

• It may cause fire and electric shock.

Do not disassemble or modify products.

• It may cause electric shock and failure.

Gasolin

Service Manual 3

Safety Precautions

Operation

Plug in the power plug properly.

Otherwise, it will cause electric shock or fire.

Do not modify power cord length.

It will cause electric shock or fire.

Unplug the unit if strange sounds, odors, or smoke come from it.

Otherwise it will cause fire and electric shock accident.

Do not operate or stop the

Do not damage or use an

unit by inserting or pulling

unspecified power cord.

out the power plug.

 

• It will cause electric shock or

• It will cause electric shock or

fire.

fire.

ON

Use the air conditioner on a

Always plug into a

single outlet circuit. (See page 7.)

grounded outlet.

Do not share the outlet with

 

other appliances.

 

• It will cause electric shock or

• No grounding may cause

fire.

electric shock.

Do not use the socket if it is

Do not operate with wet

loose or damaged.

hands or in damp

 

environment.

• It may cause fire and electric

• It may cause electric shock.

shock.

 

4 Room Air Conditioner

 

Safety Precautions

 

 

Close all doors, windows and other

Ventilate before operating air conditioner

outside openings to the room.

when gas goes out.

• The air conditioner must be operated in

• It may cause explosion, fire,and burn.

a enclosed area to be most effective.

 

If water enters the product, turn off the

Do not clean the air conditioner with

power switch of the main body of

water.

appliance. Contact service center after

 

taking the power plug out from the socket.

 

• It will cause electric shock or failure of

• Water may enter the unit and degrage the

machine.

insulation.It may cause an electric shock.

ENGLISH

CAUTION

Installation

Never touch the metal parts of the unit when removing the filter.

They are sharp and may cause injury.

Do not block the inlet or

Ensure that the outer case

outlet.

is not damaged by age or

 

wear.

•It may cause failure of appliance • If the outer case is damaged,

or performance deteriorate. it must be repaired or replaced immediately.

Leaving it damaged could result in the air conditioner falling out of the window, creating a safety hazard.

Owner ,s Manual 5

Safety Precautions

Be cautious not to touch the sharp edges when installing.

• It may cause injury.

Operation

Hold the plug by the head

Unplug the air conditioner

when taking it out.

if it will not be used for a

 

long period.

• It may cause electric shock

• It will waste power consumption

and damage.

in vain and it may cause accident.

Sharp edges

Unplug the air conditioner

Do not put a pet or house

before cleaning it.

plant where it will be

 

exposed to direct air flow.

• Since the fan rotates at high

• This could injury the pet or

speed during operation, it may

plant.

cause injury.

 

Always insert the filter

Use a soft cloth to clean. Do

securely.

not use wax, thinner, or a

Clean it every two weeks.

strong detergent.

• Operation without filters will

• The appearance of the air

cause failure.

conditioner may deteriorate,

 

change color, or develop

 

surface flaws.

Do not use this appliance for special purposes such as pets, foods, precision machinery, or objects of art.

It is an air conditioner, not a precision refrigeration system.

Do not drink water drained from air conditioner. Do not direct airflow at room occupants only.

It is not sanitary and could cause illness or personal injury hazard.

x a W

Thinner

6 Room Air Conditioner

Dimensions

Dimensions

SymbolsUsedin this Manual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that could cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

OutsideDimensions

 

 

 

W

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

Model

Dimension

 

All Model

 

 

W

mm(inch)

439(17 5/16")

H

mm(inch)

283(11 1/8")

D

mm(inch)

326(12 13/16")

Service Manual 7

Product Specifications

Product Specifications

MODELS

GWHD5000

 

ITEMS

 

 

 

COOLING CAPACITY (BTU/h)

5,000

 

 

POWER SUPPLY (Phase, V, Hz)

1ø , 115V, 60HZ

 

 

INPUT (W)

515

 

 

OPERATING CURRENT (AMP.)

4.8

 

 

REFRIGERANT CONTROL

CAPILLARY TUBE

 

 

REFRIGERANT CHARGE (R-22)

200g (7.0 Oz)

 

 

INSIDE FAN

TURBO

 

 

OUTSIDE FAN

ROPELLER FAN WITH SLINGER RING

 

 

AIR DISCHARGE

2-WAY (RIGHT AND LEFT)

 

 

CHASSIS

TOP-DOWN

 

 

PROTECTOR

• OVERLOAD PROTECTOR FOR COMPRESSOR

• INTERNAL PROTECTOR FOR FAN MOTOR

 

 

 

TEMPERATURE CONTROL

THERMOSTAT

 

 

ROCKER SWITCH-1

2 POSITIONS(POWER ON, POWER OFF)

 

 

ROCKER SWITCH-2

2 POSITIONS(HI FAN, LOW FAN)

 

 

FAN MOTOR

6 POLES

 

 

NOTICE SPECIFICATIONS ARE SUBJECT TO MINOR CHANGE WITHOUT NOTICE FOR FURTHER IMPROVEMENT.

8 Room Air Conditioner

Installation

Installation

This air conditioner is designed with a button-down chassis so it can be easily installed in a window.

SelecttheBest Location

1.To prevent vibration and noise, make sure the unit is installed securely and firmly.

2.Install the unit where the sun does not shine directly on the unit.

3.The outside of the cabinet must extend outward for at least 10" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

INSIDE

COOLED AIR

CAUTION: All side louvers of the cabinet

60"

must remain exposed on the outdside of

-

30"

the structure.

 

4. Install the unit slanted slightly so the back is slightly

Figure 1

lower than the front (about 1/4"). This will force con-

 

densed water to the outside.

 

5.Install the unit with the bottom about 30"~60" above the floor level.

OUTSIDE

FENCE

AWNING

HEAT

RADIATION

ABOUT 1/2 "

Over 20"

HowtoInstall

Window Requirements

NOTICE All supporting parts should be secured to firm wood, masonry, or metal.

1.This unit is designed for installation in standard double hung windows with actual opening widths of 21" to 35". The upper and lower sash must open sufficiently to allow a clear vertical opening of 12" from the bottom of the sash to the window stool.

2.If storm window presents interference, fasten a 2" wide wood strip to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. See Figure. 3. Top of wood strip should be approximately 3/4" higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside.

3.Install a second wood strip (approximately 6" long by 11/2" wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as shown Figure. 3.

4.If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1", two of wood strip are not necessary.

INNER SILL

 

OUTER

 

SILL

INDOORS

OUTDOORS

Figure 2

 

WOOD STRIP MOUNTED

1" MAX.

ON TOP OF INNER SILL

3/4"

 

CLEARANCE

 

STORM

INNER

WINDOW

FRAME

SILL

 

WOOD STRIP

FOR L BRACKET

 

OUTER

 

SILL

INDOORS

OUTDOORS

Figure 3

 

Service Manual 9

Loading...