SERVICE
Model AMB 859/G
Version 8528 859 10100 Page
Whirlpool Europe
Customer Services
AMB 859/G
Service Manual
Air Conditioner
Split Type
AMB 859/G
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 15.06.2004 (Mod. 01) Subject to modification
Document-No.: 4812 731 15447
20.03.2003 / Page 2 AMB 859/G Whirlpool Europe
Doc. No: 4812 731 15447 8528 859 10100 Customer Service
Technical data
SERVICE
Factory Code A-07HR4ND
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 800 mm
Width 270 mm
Depth 168 mm
Outdoor - unit
Height 755 mm
Width 530 mm
Depth 252 mm
Weight
Indoor - unit 8.5 kg / net
Outdoor - unit 37 kg / net
Cooling Capacity
2196 Watt
7500 BTU / h
Heating Capacity
2196 Watt
7500 BTU / h
Airflow / Evaporator Airvolume
420 m3 / h
Dehumidifying Capacity
0,8 l / h
Noise Level
Indoor - unit 27 - 33 dB(A)
Outdoor - unit 50 dB(A)
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Rated Current (Cooling) 3.6 A
Rated Current (Heating) 3.7 A
Energy Efficiency Rate (BTU/Watt hr)
Cooling 9.6
Heating 10.2
Compressor (cooling)
Type PG135X1C-4DT2
Capacity (CECOMAF) 2370 W
Refrigerant
Type R 407C
Quantity 700 g