S E R V I C E |
Whirlpool Europe |
Customer Services |
ADG 931/2 NB
Service Manual
Dishwasher
Compact
ADG 931/2 NB
Model |
ADG 931/2 NB |
|
|
Version |
8511 931 01360 |
Page |
|
|
Technical data |
2 |
- 4 |
|
Spare part list |
5 |
- 6 |
|
Exploded view |
7 |
- 10 |
|
Wiring diagram |
11 |
|
|
Circuit diagram |
12 |
|
|
Program diagram |
13 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 17.12.1998 |
Subject to modification |
Document-No.: 4812 718 13883 |
|
17.12.1998 / Page 2 |
ADG 931/2 NB |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 718 13883 |
8511 931 01360 |
Customer Service |
||
|
|
|
|
|
Technical data
Dimension
Height |
85 |
cm |
Width |
44.8 |
cm |
Depth |
60 |
cm |
Weight |
45 |
kg |
Wooden door |
|
|
Thickness min.. |
16 |
mm |
Thickness max. |
25 |
mm |
Width min. |
445 |
mm |
Width max. |
450 |
mm |
Height min. |
571.5 |
mm |
Height max. |
604 |
mm |
Weight min. |
1.8 |
kg |
Weight max. |
5.6 |
kg |
Max. stick out over lower |
|
|
edge of appliance door |
90 |
mm |
Specification / PI-Expression (norm. Progr.) |
||
Detergent |
25 |
gr |
Saltconsumption |
|
|
by 21 ˚deg d.H. |
28 |
gr |
Water connection up to |
60 |
˚C |
Capacity |
9 stand. place settings |
|
Volume |
|
|
Water |
|
|
Working-level |
3.75 |
l |
Safety-level |
|
|
- motor on |
9.5 |
l |
- motor off |
6.5 |
l |
Overflow-level |
6.2 |
l |
Detergent |
5+25 |
gr |
Clear rinse containing |
120 |
ccm |
Rinse dosage per step |
1- 6 |
ccm |
Salt container volume |
1.35 |
kg |
Flow rates / Inlet volumes |
|
|
Spray pump |
~ 50 |
l/min |
Drain pump |
~ 15 |
l/min |
Water inlet electrovalve |
~ 3.75 |
l/min |
Water pressure |
|
|
Inlet pressure min. |
0.3 |
bar |
Spraypump pressure |
0.3 |
bar |
Rotations |
|
|
SP-Motor |
2680 |
RPM |
DP-Motor |
2500 |
RPM |
Spray arm lower |
37 5 |
RPM |
Spray arm upper |
24 5 |
RPM |
Electrical Data |
|
|
Base level |
|
|
Voltage |
220/230 |
V |
Frequency |
50 |
Hz |
Total power |
2200 |
W |
Fuses |
10 |
A |
Timer |
|
|
Model |
Eaton EC 4707 |
|
Basic step times |
30’’-1’-2’-4’ |
|
Steps |
60 |
|
Heating |
|
|
Throughflow system |
|
|
Voltage |
220/230 |
V |
Total power |
2.05 |
kW |
Resistance |
27 |
Ω |
Motor |
|
|
Spraypumpmotor |
|
|
Voltage |
220/230 |
V |
Power consumption |
150 |
W |
HI |
38 |
Ω |
HA |
40 |
Ω |
Capacitor |
6 |
F |
To loos spraypump |
|
|
from motor |
turn anti clockwise |
|
To fit spraypump |
|
|
on motor |
turn clockwise |
|
needed racket spanner |
6 |
mm |
Drainpumpmotor |
|
|
Voltage |
220/230 |
V |
Power consumption |
23 |
W |
Resistance |
200 |
Ω |
Timer Motor |
|
|
Voltage |
220/230 |
V |
Power consumption |
3.5 |
W |
Resistance |
6450 |
Ω |
S E R V I C E
Technical data
Whirlpool Europe |
ADG 931/2 NB |
17.12.1998 / Page 3 |
Customer Service |
8511 931 01360 |
Doc. No: 4812 718 13883 |
|
|
|
Valve |
|
|
Inlet valve |
|
|
Voltage |
220-240 |
V |
Power consumption |
6 |
W |
Resistance |
3750 |
Ω |
Regeneration valve |
|
|
Voltage |
220-240 |
V |
Power consumption |
6 |
W |
Resistance |
3750 |
Ω |
Safty system against water-leakage
Aquastop + floater switch
Floter switches of the inlet valve and on the drain pump
Thermostates
Double thermostat in the Door
NA58 |
|
|
Color code |
grey |
|
Temperature |
58 |
˚C |
closes when temperature is reached |
|
|
NC72 |
|
|
Color code |
red |
|
Temperature |
72 |
˚C |
opens when temperature is reached
Water measuring
Remove the coases sieve, put into the sump a meassuring meter, look the height of the water
level |
|
|
Working level |
110 |
mm |
Safety level |
125 |
mm |
Pressostat |
|
|
Working level |
|
|
Niveau |
80/60 3 |
mm |
Safety level (against overflow) |
|
|
Niveau |
125/75 3 mm |
High pressure pressostat (against heating without water)
Niveau |
2400/1500mm |
17.12.1998 / Page 4 |
ADG 931/2 NB |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 718 13883 |
8511 931 01360 |
Customer Service |
||
|
|
|
|
|
Technical data