Viking VCIH56608SM, VCIH56608VC, VCIH56608SB, VCIH56608PG, VCIH56608RE Installation Manual

...
0 (0)

Installation

Professional Indoor & Outdoor Hoods

VWH53012 / VWH53612

VWH53048 / VWH53648 / VWH54248

VWH54848 / VWH56048

VCWH53048 / VCWH53648 / VCWH54248

VCWH54848 / VCWH56048

VCIH53608 / VCIH54208 / VCIH55408 / VCIH56608

VBCV53638 / VBCV54238 / VBCV54838 / VBCV56038 / VBCV56038

VWHO3678 / VWHO4878 / VWHO6078 (Canadian Outdoor models not applicable)

Table of Contents

Warnings & Important Information _________________________________________________________________ 3-4 VWH/CVWH 10” H/12”H. Wall Hoods w/Standard Ventilator 30”, & 36”

Dimensions & Specifications_______________________________________________________________ 5 Clearance Dimensions_____________________________________________________________________ 6 Interior Ventilator Dimensions ____________________________________________________________ 7

VWH/CVWH 18”H. 24”Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”

Dimensions & Specifications ______________________________________________________________ 8 Clearance Dimensions _______________________________________________________________________ 9 Interior Ventilator Dimensions _____________________________________________________________ 10 Exterior Ventilator Dimensions ___________________________________________________________ 11

VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”

Dimensions & Specifications ______________________________________________________________ 12 Clearance Dimensions ____________________________________________________________________ 13

VCWH/CVCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, & 60”

Dimensions & Specifications ______________________________________________________________ 14 Clearance Dimensions ____________________________________________________________________ 15 Interior Ventilator Dimensions ____________________________________________________________ 16 Exterior Ventilator Dimensions ___________________________________________________________ 17

VCIH/CVCIH Chimney Island Hoods 36”, 42”, 54”, & 66”

Dimensions & Specifications ______________________________________________________________ 18 Clearance Dimensions ____________________________________________________________________ 19 Interior Ventilator Dimensions ____________________________________________________________ 20 Exterior Ventilator Dimensions ___________________________________________________________ 21

VBCV/CVBCV Wall Custom Ventilator System

Dimensions & Specifications ______________________________________________________________ 22 Installing Hood Canopy___________________________________________________________________ 23 Clearance Dimensions ____________________________________________________________________ 24 VBCV Ventilator Dimensions ______________________________________________________________ 25 Planning Information _________________________________________________________________________ 27

Installation Procedures

Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) ___________________ 28 Duct Cover Option (VWH/CVWH 12”H. Wall Hoods w/Standard Ventilator) __________________ 30 Installation (VWH/CVWH 12”H. Wall Hoods w/Recirculating Kit) ____________________________ 30 Installation (VWH/CVWH 18”H. Wall & VCWH Chimney Wall Hoods) _________________________ 33 Duct Cover Option (VWH/CVWH 18”H. Wall Hoods) ________________________________________ 34 Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods) __________________________________ 35 Installation (VCIH Island Hoods)___________________________________________________________ 36

Service & Registration ________________________________________________________________________ 38 Wiring Diagram ______________________________________________________________________________ 39

2

IMPORTANT–Please Read and Follow!

NOTE: If installing hood with warming shelf panel, install warming shelf panel first.

IMPORTANT – PLEASE READ AND FOLLOW

Before beginning, please read these instructions completely and carefully.

Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.

Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.

Damp environment approved models should be installed in a covered non-enclosed area and should be protected from the elements as much as possible.

The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.

Check with a qualified and trained installer or local codes for makeup air requirement, if any.

This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning. Viking hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any nonViking Range ventilator kit will void the hood warranty.

Viking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking ventilator kits are designed specifically for use with Viking hoods. Use of any non-Viking ventilator kit will void the hood warranty.

READ AND SAVE THESE INSTRUCTIONS

WARNING

To reduce the risk of fire, electric shock, or injury to persons, observe the following:

Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including firerated construction.

2.Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

3.When cutting of drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

4.Ducted fans must always be vented to the outdoors.

5.WARNING!: To reduce risk of fire, use only metal ductwork

6.CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages.

7.CAUTION!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models manufactured by Viking, model numbers – DEV900/DEV1200, VEV900, VIL1200, OR DEV1500 or integral blowers manufactured by Viking, model numbers – VINV300/600/1200, or DIL1200. NOTE – Please refer inside for specific canopy/blower combinations.

3

IMPORTANT–Please Read and Follow!

WARNING

To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen Firesafety Tips,” published by NFPA.)

1.SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN. You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result.

4.Use an extinguisher ONLY if

You know it is a Class ABC extinguisher, and you already know how to operate it.

The fire is small and contained in the area where it started.

The fire department is being called.

You can fight the fire with your back to an exit.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

WARNING

TO REDUCE THE RISK OF FIRE,

ELECTRICAL SHOCK, OR INJURY

TO PERSONS

Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with this

model. Other ventilators cannot be substituted.

WARNING

This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

4

Dimensions & Specifications

(VWH 10”H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”)

12 (30.5

” cm)

 

 

 

 

10”

 

 

 

 

 

(25.

 

 

5”

 

 

4

cm)

 

 

 

(12.

 

 

 

 

 

 

7

cm)

 

 

 

 

 

 

A

21”

 

 

 

 

 

 

 

 

.3

cm)

 

 

 

 

 

(53

 

 

 

 

 

A (Hood width)

 

 

 

 

 

30”W.

29-7/8“ (76.2 cm)

 

 

 

 

 

36”W.

35-7/8” (91.1 cm)

 

5”

 

 

 

 

 

 

 

 

(12.

 

 

 

 

 

7

cm)

 

 

 

 

 

 

A

12 (30.5

12 (30.5

21”

.3

cm)

(53

 

” cm)

” cm)

 

A (Hood width)

30”W.

 

29-7/8“ (76.2 cm)

36”W.

 

35-7/8” (91.1 cm)

NOTE: Optional duct cover sold separately.

VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator

Description

30”

 

36”

 

 

 

 

 

Duct cover width

29-7/8” (75.9 cm)

 

35-7/8” (91.1 cm)

 

 

 

 

Duct cover depth

 

12” (30.5 cm)

 

 

 

Duct cover height

 

12” (30.5 cm)

 

 

 

Number of lights

 

2

 

 

 

Number of filters

 

2

 

 

 

 

Heat lamps

 

 

N/A

 

 

 

Interior ventilator kit

 

460 CFM Standard

 

 

 

Interior duct size*

 

7” (17.8 cm)

 

 

 

 

Interior—Maximum amps

 

 

5.6 A

 

 

 

 

* Disregard when using recirculating kits. 460 CFM blower is shipped with hood.

5

Viking VCIH56608SM, VCIH56608VC, VCIH56608SB, VCIH56608PG, VCIH56608RE Installation Manual

Clearance Dimensions

(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)

36"

.4

cm)

(91

 

 

 

 

60"

 

 

24"

 

(152.

 

(61.

 

 

min.

 

 

4

 

 

0min.

to cm)

27"

 

cm)

63"

max.

to

 

(68.

 

(160.

 

 

max.

 

0

 

 

 

cm)

 

6

*

 

 

 

 

cm)

* NOTE: When installing with a 24” high-shelf, the 27” (68.6 cm) max. dimensions must be used.

6

Interior Ventilator Dimensions

(VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator)

Top View

A

24”W. 23-7/8” (60.6 cm)

30”W. 29-7/8” (75.9 cm)

36”W. 35-7/8” (91.1 cm)

B

24”W. 5-1/4” (13.3 cm)

30”W. 8-1/4” (20.9 cm)

36”W. 11-1/4” (28.6 cm)

C

24”W. 11-15/16” (30.3 cm)

30”W. 14-15/16” (37.9 cm)

36”W. 17-15/16” (45.6 cm)

D

24”W. 5/8” (1.6 cm)

30”W. 3-5/8” (9.2 cm)

36”W. 6-5/8” (16.8 cm)

 

 

A

 

 

 

18”

 

B

 

(4.6 cm)

D

 

C

3-4”

1/2”

 

(1.9 cm)

 

 

(1.3 cm)

 

 

 

4”

 

 

3-1/2”

(10.2 cm)

 

 

(8.9 cm)

 

 

3-7/8”

Electrical

 

 

(9.8 cm)

hookup

 

 

 

 

 

7” (17.8 cm) dia.

 

 

 

duct location

 

460 CFM Interior Ventilator Installation

7

Dimensions & Specifications

(VWH/CVWH 18”H. 24”Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)

A

30" W 29-7/8" (76.2 cm)

36" W 35-7/8" (91.1 cm)

42" W 41-7/8" (106.4 cm)

48" W 47-7/8" (121.6 cm)

60" W 59-7/8" (152.1 cm)

6"

 

 

(15.

 

 

2

cm)

 

12"

(30.

 

5

cm)

 

18"

(45.

 

7

cm)

 

A

24"

.0

cm)

(61

 

NOTE: Optional duct cover sold separately.

VWH/CVWH 18”H. Wall Hoods

Description

30”

36”

42”

48”

60”

Duct cover width

29-7/8”

35-7/8”

41-7/8”

47-7/8”

59-7/8” (152.1

 

(75.9 cm)

(91.1 cm)

(106.4 cm)

(121.6 cm)

cm)

Duct cover depth

 

 

12” (30.5 cm)

 

 

Duct cover height

 

 

12” (30.5 cm)

 

 

Number of lights

2

2

2

3

4

Number of filters

2

2

2

3

4

Heat lamps

1

1

1

2

3

Interior ventilator kits

VINV300/

VINV300/

VINV600/

VINV1200*

VINV1200*

 

600/1200

600/1200

1200

 

 

Exterior ventilator kits

DEV900/

DEV900/

DEV900/

DEV1200*/

DEV1200*/

 

1200*

1200*

1200*

1500**

1500**

In-line ventilator kits

DIL1200

DIL1200

DIL1200

DIL1200

DIL1200

Interior duct size

7”/10”

7”/10”

7”/10”

10”

10”

 

(17.8/25.4 cm)

(17.8/25.4 cm)

(17.8/25.4 cm)

(25.4 cm)

(25.4 cm)

Exterior duct size

 

 

10” (24.5 cm)

 

 

Interior—Maximum amps

4.2/5.2/8.2

4.2/5.2/8.2

5.2/8.2

10.8

10.8

Exterior—Maximum amps

8.0/5.3

8.0/5.3

8.0/5.3

7.8/8.5

7.8/8.5

In-Line—Maximum amps

5.3/7.2

5.3/7.2

5.3/7.2

9.6

10.0

 

 

 

 

 

 

*A 1,200 CFM interioror exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interioror exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

8

Clearance Dimensions

(VWH/CVWH 18”H. Wall Hoods)

66”

 

 

 

 

 

(167.min.

30”

 

 

6

cm)

 

to

(76.

 

72”

 

 

 

 

max.

 

2min.

 

 

 

cm)

(182.

 

36”

to

 

9

cm)

 

 

4max.

 

 

 

 

 

 

(91.

cm)

 

 

 

 

 

36”

.4

cm)

(91

 

 

 

 

9

Interior Ventilator Dimensions

(VWH/CVWH 18”H. Wall Hoods)

Top View

 

 

 

 

 

 

 

 

 

A

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30" W

14-15/16" (37.9 cm)

 

 

 

 

 

 

 

 

 

30" W

29-7/8" (75.9 cm)

 

 

 

4-5/8"

 

 

 

 

 

 

 

36" W

17-15/16" (45.6 cm)

 

 

 

 

 

 

36" W

35-7/8" (91.1 cm)

42" W

20-15/16" (53.2 cm)

 

 

(11.7 cm)

 

 

 

42" W

41-7/8" (106.4 cm)

48" W

23-15/16" (60.8 cm)

 

 

 

 

 

 

 

 

 

 

48" W

47-7/8" (121.6 cm)

60" W

29-15/16" (76.0 cm)

 

 

 

 

 

 

 

 

 

60" W

59-7/8" (152.1 cm)

 

 

 

 

 

7" (17.8 cm)

 

 

 

 

 

 

 

 

 

 

dia. duct location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300 or 600 CFM Interior Ventilator Installation for all Wall Hoods

Top View

 

A

 

 

 

 

 

 

A

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30" W

14-15/16" (37.9 cm)

 

 

 

 

 

 

 

 

30" W

29-7/8" (75.9 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

36" W

17-15/16" (45.6 cm)

 

5-1/2"

 

 

 

 

36" W

35-7/8" (91.1 cm)

42" W

20-15/16" (53.2 cm)

 

 

(14.0 cm)

 

 

 

 

42" W

41-7/8" (106.4 cm)

48" W

23-15/16" (60.8 cm)

 

 

 

 

 

 

 

 

 

48" W

47-7/8" (121.6 cm)

 

 

 

 

 

 

 

60" W

29-15/16" (76.0 cm)

 

10" (25.4 cm)

 

 

 

 

60" W

59-7/8" (152.1 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dia. duct location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200 CFM Interior Ventilator Installation for all Wall Hoods

10

Exterior Ventilator Dimensions

(VWH/CVWH 18”H. Wall Hoods)

Top View

 

 

 

 

 

 

 

 

A

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30" W

14-15/16" (37.9 cm)

 

 

 

 

 

 

 

 

30" W

29-7/8" (75.9 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

36" W

17-15/16" (45.6 cm)

 

5-15/16"

 

 

 

 

 

36" W

35-7/8" (91.1 cm)

42" W

20-15/16" (53.2 cm)

 

 

 

 

 

 

42" W

41-7/8" (106.4 cm)

(15.1 cm)

 

 

 

48" W

23-15/16" (60.8 cm)

 

 

 

 

 

 

 

 

 

48" W

47-7/8" (121.6 cm)

60" W

29-15/16" (76.0 cm)

 

 

 

 

 

 

 

 

60" W

59-7/8" (152.1 cm)

 

 

 

10" (25.4 cm)

 

 

 

 

 

 

 

 

dia. duct location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Wall Hoods

Top View

 

A

 

 

 

 

 

 

 

A

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30" W

14-15/16" (37.9 cm)

 

 

 

 

 

 

 

 

 

 

30" W

29-7/8" (75.9 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

5-15/16"

 

 

 

 

 

 

 

 

36" W

17-15/16" (45.6 cm)

 

 

 

 

 

 

 

36" W

35-7/8" (91.1 cm)

42" W

20-15/16" (53.2 cm)

 

(15.1 cm)

 

 

 

 

42" W

41-7/8" (106.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48" W

23-15/16" (60.8 cm)

 

 

 

 

 

 

 

 

 

 

 

48" W

47-7/8" (121.6 cm)

60" W

29-15/16" (76.0 cm)

 

 

 

 

 

 

 

 

 

 

60" W

59-7/8" (152.1 cm)

 

 

 

 

10" (25.4 cm)

 

 

 

 

 

 

 

 

 

 

dia. duct location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all Wall Hoods

11

Dimensions & Specifications

(VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)

6

 

 

(15.

"

 

 

2

cm)

 

 

A

36" W 35-7/8" (91.1 cm)

48" W 47-7/8" (121.6 cm)

60" W 59-7/8" (152.1 cm)

A

18"

(45.

 

7

cm)

 

27

"

.6

cm)

(68

 

VWHO/CVWHO 18”H. Outdoor Wall Hoods

Description

36”

48”

60”

Number of lights

2

3

4

 

Number of filters

2

3

4

 

Interior ventilator kits

VINV1200*

VINV1200*

VINV1200*

Exterior ventilator kits

DEV1200*/1500**

DEV1200*/1500**

DEV1200*/1500**

In-line ventilator kits

DIL1200

DIL1200

DIL1200

Interior duct size

 

10” (25.4 cm)

 

 

Exterior duct size

 

10” (25.4 cm)

 

 

Interior—Maximum amps

9.0

11.4

11.8

 

Exterior—Maximum amps

6.1/6.8

8.4/9.1

8.8/9.5

 

In-Line—Maximum amps

7.9

10.2

10.6

 

*A 1,200 CFM interioror exterior-power ventilator should be used with all outdoor models and when indoor models are installed over range/rangetop with gas char-grill. Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interioror exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

12

Loading...
+ 28 hidden pages