1. INTRODUCTION
To all residents of the European Union Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.
The DVM810 is a compact multimeter with a 3 1/2 digit LCD for measuring DC and AC voltages, DC currents, resistance, diodes and transistors (hFE). Full overload protection is provided. It is an ideal instrument for hobbyists, for use in the field, for laboratories and workshops and for domestic applications.
2. FRONT PANEL DESCRIPTION
1. FUNCTION AND RANGE SWITCH
This switch is used to select the desired function and range. It also activates the instrument. Place the switch in the "OFF" position when the instrument is not in use in order to extend the life of your battery.
2. DISPLAY
3 1/2 digit display with 7 segments. Height : 0.5" (12.7mm)
3. "COMMON" JACK
Plug in the connector for the black (-) test lead.
4. "VmA" JACK
Plug in the connector for the red (+) test lead when you wish to measure voltages, resistances and currents (with the exception of 10A-measurements).
5. "10A" JACK
Plug in the connector for the red (+) test lead for all your 10A measurements.
6. TRANSISTOR JACK
Plug in the transistor for hFE-measurements of a NPN or PNP transistor. Use the correct b.e.c.-connections.
3. SPECIFICATIONS
Maximum accuracy is guaranteed for a one-year period after calibration. Ideal circumstances require a temperature of 23°C (± 5° C) and a max. relative humidity of 75%.
DVM810 VELLEMAN
4
3.1. DC VOLTAGE
Range Resolution Accuracy 200mV 100µ V ±0.25% of rdg ± 2 digits
2000mV 1mV
20V 10mV 200V 100mV 500V 1V
±0.5% of rdg ± 2 digits
Overload protection : 220Vrms AC for the 200mV range and 1500V DC or 500Vrms AC for other ranges.
3.2. AC VOLTAGE
Range Resolution Accuracy
200V 100mV ±1.2% of rdg ± 1 digit 500V 1V ±1.2% of rdg ± 1 digit
Overload protection : 500V DC or 500V rms for all ranges. Response : average response, calibration in rms of a sine wave. Frequency range : 45Hz – 450Hz
3.3. DC CURRENT
Range Resolution Accuracy 200µ A 100nA
2000µA 1µ A
20mA 10µ A
±1.0% of rdg ± 2 digits
200mA 100µ A ±1.2% of rdg ± 2 digits
10A 10mA ±2.0% of rdg ± 2 digits
Overload protection : 200mA 250V fuse (10A-range is not fuse-protected) Measuring voltage drop : 200mV
3.4. RESISTANCE
Range Resolution Accuracy
200 100m
2000 1
20k 10
200k 100
±0.8% of rdg ± 2 digits
2000k 1k ±1.0% of rdg ± 2 digits Max. open circuit voltage : 2.8V Overload protection : max. 220Vrms for 15 seconds on all ranges
4. OPERATING INSTRUCTIONS
4.1. WARNING
1. Do not measure voltages that exceed the earthing level by more than 500V in order to avoid all risks of electroshocks or
damage to the instrument.
2. Make sure the insulation of all test leads, probes and connectors is intact prior to activating the device.
4.2. DC VOLTAGE MEASUREMENTS
1. Connect the red test lead to the "VmA" jack and the black lead to the "COM" jack.
2. Place the RANGE switch in the appropriate VDC position. Set the switch to the highest range and work your way down if
the voltage range is unknown beforehand.
3. Connect the test leads to the device or circuit to be measured.
4. Activate the device or circuit to be measured. Both the voltage reading and the polarity will be displayed.
DVM810 VELLEMAN
5
4.3. AC VOLTAGE MEASUREMENTS
1. Connect the red test lead to the "VmA" jack and the black lead to the "COM" jack.
2. Place the RANGE switch in the appropriate VAC position. Set the switch to the highest range and work your way down if
the voltage range is unknown beforehand.
3. Connect the test leads to the device or circuit to be measured.
4. Activate the device or circuit to be measured. The voltage value will appear on the display.
4.4. DC CURRENT MEASUREMENTS
1. Connect the red test lead to the "VmA" jack and the black lead to the "COM" jack. (Connect the red test lead to the
"10A"-jack for measurements between 200mA and 10A).
2. Place the RANGE switch in the appropriate ADC position. Set the switch to the highest range and work your way down if
the voltage range is unknown beforehand.
3. Open the circuit to be measured and connect the test leads IN SERIES with the load of which the current is to be
measured.
4. Activate the device or circuit to be measured. The current value will appear on the display.
4.5. RESISTANCE MEASUREMENTS
1. Connect the red test lead to the "VmA" jack and the black lead to the "COM" jack.
2. Place the RANGE switch in the appropriate Ω position.
3. If the resistance to be measured is connected to a circuit : disconnect the power and discharge all capacitors prior to
measurement.
4. Connect the test leads to the circuit to be measured.
5. The resistance value will be displayed.
4.6. DIODE MEASUREMENTS
1. Connect the red test lead to the "VmA" jack and the black lead to the "COM" jack.
2. Set the RANGE switch to the position.
3. Connect the red test lead to the anode and the black test lead to the cathode of the diode to be measured.
4. The forward voltage drop will be displayed in mV. "1" will be displayed if the polarity of the diode is reversed.
4.7. TRANSISTOR hFE-MEASUREMENTS
1. Set the RANGE switch to the hFE-position.
2. Determine whether the transistor is NPN or PNP and locate the emitter, base and collector leads. Insert the leads into the
proper holes of the hFE-socket on the front panel.
3. The display will show the approximate hFE-value at the moment of testing. Base current 10µA, Vce 2.8V.
5. BATTERY AND FUSE REPLACEMENT
CAUTION
All test leads should be disconnected from energised circuits prior to opening the case. This eliminates the risk of electroshocks.
- The fuse rarely needs to be replaced and a blown fuse is nearly always due to an error on behalf of the operator.
- Replace the battery when the display reads "BAT".
- In order to replace the battery (type GP23GA) or the fuse (200mA/250V) : loosen and remove the 2 screws at the back of
the device. Remove the old battery or fuse and insert a new one. Observe the polarity !
DVM810 VELLEMAN
6
6. ACCESSORIES
- instruction manual
- a set of test leads
- a GP23GA-battery of 12V
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulted from (incorrect) use of this device. For more info concerning this product, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice.
DVM810 – MINI 3 ½-DIGIT DMM - 19 BEREIKEN
1. INLEIDING
Aan alle ingezetenen van de Europese Unie Belangrijke milieu-informatie betreffende dit product
Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt weggeworpen, dit toestel schade kan toebrengen aan het milieu. Gooi dit toestel (en eventuele batterijen) niet bij het gewone huishoudelijke afval; het moet bij een gespecialiseerd bedrijf terechtkomen voor recyclage. U moet dit toestel naar uw verdeler of naar een lokaal recyclagepunt brengen. Respecteer de plaatselijke milieuwetgeving.
Hebt u vragen, contacteer dan de plaatselijke autoriteiten inzake verwijdering.
Dank u voor uw aankoop! Lees deze handleiding grondig voor u het toestel in gebruik neemt. Werd het toestel beschadigd tijdens het transport, installeer het dan niet en raadpleeg uw dealer.
De DVM810 is een compacte multimeter met een 3 1/2 digit LCD. Met dit apparaat kunt u gelijk- en wisselspanning, gelijkstroom, weerstand, diodes en transistors (hFE) meten. Het apparaat is beveiligd tegen overbelasting en is ideaal voor hobbyisten, praktijkoefeningen, wetenschappelijk onderzoek, ateliers en gebruik bij u thuis.
2. BESCHRIJVING VAN HET FRONTPANEEL
1. FUNCTIE- en BEREIKSCHAKELAAR
Met deze schakelaar activeert u het toestel en kunt u het bereik en de functie instellen. Plaats de schakelaar in de "OFF"-stand wanneer u het apparaat niet gebruikt. Zo verhoogt u de levensduur van de batterij.
2. DISPLAY
3 1/2 digit LCD met 7 segmenten. Hoogte : 12.7mm
3. "COMMON" AANSLUITING
Plug de connector in van het zwarte (-) meetsnoer.
4. "VmA" AANSLUITING
Plug de connector in van het rode (+) meetsnoer om spanning, weerstand en stroom te meten (uitgez. stroom van 10A).
5. "10A" AANSLUITING
Plug de connector in van het rode (+) meetsnoer voor al uw 10A-metingen.
6. TRANSISTORAANSLUITING
Plug de transistor in voor hFE-metingen van een NPN of PNP transistor. Gebruik de juiste b.e.c.-aansluitingen !
DVM810 VELLEMAN
7
3. SPECIFICATIES
Tot één jaar na de ijking mag u optimale nauwkeurigheid verwachten. De ideale weersomstandigheden zijn : 23°C (± 5°C) en een max. relatieve vochtigheidsgraad van 75%.
3.1. DC SPANNING
Bereik Resolutie Nauwkeurigheid 200mV 100µ V ±0.25% van uitlezing ± 2 digits
2000mV 1mV
20V 10mV 200V 100mV 500V 1V
±0.5% van uitlezing ± 2 digits
Bescherming tegen overbelasting : 220Vrms AC voor het 200mV-bereik en 1500V DC of 500Vrms AC voor elk ander bereik.
3.2. AC SPANNING
Bereik Resolutie Nauwkeurigheid
200V 100mV ±1.2% van uitlezing ± 1 digit 500V 1V ± 1.2% van uitlezing ± 1 digit
Bescherming tegen overbelasting : 500V DC of 500V rms voor elk bereik. Respons : gemiddeld, ijking in rms van een sinusgolf. Frequentiebereik : 45Hz – 450Hz
3.3. DC STROOM
Bereik Resolutie Nauwkeurigheid 200µ A 100nA
2000µA 1µ A
20mA 10µ A
±1.0% van uitlezing ± 2 digits
200mA 100µ A ±1.2% van uitlezing ± 2 digits
10A 10mA ±2.0% van uitlezing ± 2 digits
Bescherming tegen overbelasting : 200mA 250V zekering (10A-bereik is niet beveiligd door een zekering)
Meten van spanningsval : 200mV
3.4. WEERSTAND
Bereik Resolutie Nauwkeurigheid
200 100m
2000 1
20k 10
200k 100
±0.8% van uitlezing ± 2 digits
2000k 1k ±1.0% van uitlezing ± 2 digits Max. spanning voor open circuit : 2.8V Bescherming tegen overbelasting : max. 220Vrms gedurende 15sec. voor elk bereik.
4. GEBRUIK
4.1. OPGELET
1. Meet geen spanningen die het aardingsniveau met meer dan 500V overschrijden. Zo wordt elk risico op verwondingen of
beschadiging van het toestel vermeden.
2. Controleer de isolatie van alle meetsnoeren, meetpennen en connectors VÓÓR u het toestel gebruikt.