The SIBTF10xx-1xx-Mx Ethernet industrial switches
allow connecting 10Base-T Ethernet/100Base-TX fast
Ethernet twisted-pair copper network devices to
network devices on a 100Base-FX fast Ethernet fiber
140-MR
and one fiber port. The SIBTF10xx-140-MR model includes redundant power-supply
terminal blocks that can handle 48–170VDC or 90–125VAC, 50/60Hz input power. The
SIBTF10xx-140-MS model, not shown, has a single power-supply terminal block (TB).
The SIBTF10xx-130-MR has three RJ-45 copper ports
and two fiber ports. The SIBTF10xx-130-MR model
includes redundant power-supply terminal blocks that
can handle 48–170VDC or 90–125VAC, 50/60Hz
input power. The SIBTF10xx-130-MS model, not
shown, has a single power-supply terminal block (TB).
network.
The SIBTF10xx-140-MR has four RJ-45 copper ports
110-MR
130-MR
The SIBTF10xx-110-MR has one RJ-45 copper port
and one fiber port. The SIBTF10xx-110-MR model
includes redundant power-supply terminal blocks that
can handle 48–170VDC or 90–125VAC, 50/60Hz
input power. The SIBTF10xx-110-MS model, not
shown, has a single power-supply terminal block (TB).
Available Models . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . .15
Cable Specifications . . . . . . . . . .20
Technical Specifications . . . . . . .22
Troubleshooting . . . . . . . . . . . . .24
Contact Us . . . . . . . . . . . . . . . . .26
Compliance Information . . . . . . .27
SIBTF10xx-1xx-Mx
Available Models
Available SIBTF10xx-140-MR and MS models*
Part Number(4) Copper - 10Base-T/
100Base-TX ports
SIBTF1011-140-Mx
SIBTF1013-140-Mx
SIBTF1014-140-Mx
SIBTF1015-140-Mx
SIBTF1016-140-Mx
SIBTF1017-140-Mx
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
*MR = Redundant power-supply terminal blocks, MS = Single power-supply terminal block.
Note: The cable distances listed are maximum distances typically. The actual distance
is dependent upon the physical characteristics of the network.
Available SIBTF10xx-130-MR and MS models*
Part Number(3) Copper - 10Base-T/
SIBTF1011-130-Mx
SIBTF1013-130-Mx
SIBTF1014-130-Mx
SIBTF1015-130-Mx
SIBTF1016-130-Mx
SIBTF1017-130-Mx
100Base-TX Ports
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
(1) Duplex Fiber-Optic - 100Base-FX port
ST, 1300 nm multimode, duplex
2 km (1.2 miles)
SC, 1300 nm multimode, duplex
2 km (1.2 miles)
SC, 1310 nm single mode, duplex
20 km (12.4 miles)
SC, 1310 nm single mode, duplex
40 km (24.8 miles)
SC, 1310 nm single mode, duplex
60 km (37.2 miles)
SC, 1550 nm single mode, duplex
80 km (49.7 miles)
(2) Duplex Fiber-Optic - 100Base-FX
Ports
ST, 1300 nm multimode, duplex
2 km (1.2 miles)
SC, 1300 nm multimode, duplex
2 km (1.2 miles)
SC, 1310 nm single mode, duplex
20 km (12.4 miles)
SC, 1310 nm single mode, duplex
40 km (24.8 miles)
SC, 1310 nm single mode, duplex
60 km (37.2 miles)
SC, 1550 nm single mode, duplex
80 km (49.7 miles)
Available Models -- continued
Available SIBTF10xx-110-MR and MS models*
Part Number(1) Copper - 10Base-T/
100Base-TX Port
SIBTF1011-110-Mx
SIBTF1013-110-Mx
SIBTF1014-110-Mx
SIBTF1015-110-Mx
SIBTF1016-110-Mx
SIBTF1017-110-Mx
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
RJ-45
100 m (328 ft)
*MR = Redundant power-supply terminal blocks, MS = Single power-supply terminal block..
Note: The cable distances listed are maximum distances typically. The actual distance
is dependent upon the physical characteristics of the network.
(1) Duplex Fiber-Optic - 100Base-FX Port
ST, 1300 nm multimode, duplex
2 km (1.2 miles)
SC, 1300 nm multimode, duplex
2 km (1.2 miles)
SC, 1310 nm single mode, duplex
20 km (12.4 miles)
SC, 1310 nm single mode, duplex
40 km (24.8 miles)
SC, 1310 nm single mode, duplex
60 km (37.2 miles)
SC, 1550 nm single mode, duplex
80 km (49.7 miles)
*MR = Redundant power-supply terminal blocks, MS = Single power-supply terminal block.
Note: The cable distances listed are maximum distances typically. The actual distance
is dependent upon the physical characteristics of the network.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
SIBTF10xx-1xx-Mx
Installation
Features
• The SIBTF10xx-140-MR industrial switch includes four (4) RJ-45, twisted-pair
copper ports and one (1) 100 Mb fiber optic port.
• The Auto-Negotiation feature on port “1” can be turned OFF and forced to a
selected speed (100 Mb/s or 10 Mb/s) also duplex mode (full or half).
• All SIBTF models include a primary input terminal block (TB) for 48–170VDC or
90–125VAC power, a 2.5A, 250V fuse, an LED power indicator, and a red-fault
LED. The red-fault LED “ON state” indicates the microcontroller did not initialize
correctly.
• The “MR” models include an auxiliary power-supply terminal block—not available
on “MS” models.
See Figure 1.
Installation -- continued
Features -- continued
• The SIBTF10xx-130-MS industrial switch includes three (3) RJ-45, twisted-pair
copper ports and one (2) 100 Mb fiber optic port.
• The Auto-Negotiation feature on port “1” can be turned OFF and forced to a
selected speed (100 Mb/s or 10 Mb/s) and duplex mode (full or half).
• All SIBTF models include a primary input terminal block (TB) for 48–170VDC or
90–125VAC input power power, a 2.5A, 250V fuse, an LED power indicator, and a
red-fault LED. The red-fault LED “ON state” indicates the microcontroller did not
initialize correctly.
• The “MR” models include an auxiliary power-supply terminal block—not available
on “MS” models.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
SIBTF10xx-1xx-Mx
Installation -- continued
Features -- continued
• The SIBTF10xx-110-MS industrial switch includes one (1) RJ-45, twisted-pair
copper port and one (1) 100 Mb fiber optic port.
• The Auto-Negotiation feature on port “1” can be turned OFF and forced to a
selected speed (100 Mb/s or 10 Mb/s) and duplex mode (full or half).
• All SIBTF models include a primary input terminal block (TB) for 48–170VDC or
90–125VAC power, a 2.5A, 250V fuse, an LED power indicator, and a fault LED.
The red-fault LED “ON state” indicates the microcontroller did not initialize
correctly.
• The “MR” models include an auxiliary power-supply terminal block—not available
on “MS” models.
See Figure 3.
Installation -- continued
Enclosure top view (configuration switches)
The SIBTF10xx-1xx-Mx has eight (8) configuration (DIP) switches located under the
switch cover on top of the enclosure. See Figure 4.
Switch Position 1
1-Config Switches
Figure 4: Enclosure Top View Configuration Switches
1. Using a small, phillips-head screwdriver, loosen (do not remove) the two screws
that secure the cover to the switch.
2. Swing the switch cover counter-clockwise to expose the DIP switches.
3. Use a small, flathead screwdriver to set the recessed switches as required by the
network application.*
4. Slide the switch cover back over the DIP switches and then secure it by
tightening both screws.
*Note: Switches 1, 2, and 3 apply only to twisted-pair “copper port #1.”
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
7
SIBTF10xx-1xx-Mx
g
Installation -- continued
DIP switch settings
1. Port 1 copper Auto-Negotiation:
UP (Enabled) - Advertises switch speed and mode
capabilities to the network:
• 100Mb/s full-duplex • 100Mb/s half-duplex,
• 10Mb/s full-duplex • 10Mb/s half-duplex.
DOWN (Disabled) - Does not advertise switch speed
and mode capabilities to the network. With AutoNegotiate disabled switches 2 and 3 are used to set the
twisted-pair speed and mode.
2. Port 1 copper speed:
UP (100Base-TX) - Sets the twisted-pair speed to
100Base-TX.
DOWN (10Base-T) - Sets the twisted-pair speed to
10Base-T.
3. Port 1 copper duplex:
UP (Full-Duplex) - The twisted-pair cable distances
are constrained by the cable requirements.
DOWN (Half-Duplex): - The twisted-pair cable
distances are constrained by the 512-Bit Rule.
4. Fiber port FX 1 duplex:
UP (Full-Duplex) - The cable distances for the fiber
port are constrained by the cable requirements.
DOWN (Half-Duplex) - The cable distances for the
fiber port are constrained by the 512-Bit Rule.
1
Auto-Negotiation E nabled
Auto-Ne
otiation Dis abled
2
100Bas e-TX
10Bas e-TX
3
Full Duplex
Half Duplex
4
Full Duplex (fiber)
Half Duplex (fiber)
Installation -- continued
6. Link Pass-Through (model 110 only):
UP (Enable) - When Link Pass-Through is enabled, a fault
on one side of the switch stops the signal and data
transmission on the other side. See the detailed explanation
of Link Pass-Through on page 18.
DOWN (Disable) - When Link Pass-Through is disabled, a
fault on one side of the switch does not stop the signal and
data transmission on the other side.
7. Fiber redundancy (model 130 only):
UP (Disable) - When fiber redundancy is disabled, the
two fiber ports (1 and 2) act as normal bridging ports.
DOWN (Enable) - When fiber redundancy is enabled,
the two fiber ports (1 and 2) are configured as
forwarding or disabled. At any given time one port will
be disabled and one port will be forwarding.
8. AutoCross:
UP (Enable) - The switch will connect to a straightthrough or a crossover twisted-pair copper cable
automatically.
DOWN (Disable) - In the down position the straightthrough or crossover twisted-pair copper cable must be
installed according to the site requirements.
6
Link Pa ss- Through E nabled
Link Pa ss- Through Disabled
7
Redund ant Fiber E nabled
Redund ant Fiber Disabled
8
AutoCross E nabled
AutoCross Disab led
5. Fiber port FX 2 duplex (model 130 only):
UP (Full-Duplex) - The cable distances for the fiber
port are constrained by the cable requirements.
DOWN (Half-Duplex) - The cable distances for the
fiber port are constrained by the 512-Bit Rule.