Installation Manual
Concealed Duct type (Underside intake)
High-Efficiency Filter
Model: TCB-UFM11BE (65%) TCB-UFM21BE (65%) TCB-UFM31BE (65%) TCB-UFM41BE (65%)
TCB-UFH51BE (90%)
TCB-UFH61BE (90%)
TCB-UFH71BE (90%)
TCB-UFH81BE (90%)
NOTES
•This manual should be stored together with the Owner's manual and indoor unit installation manual.
SAFETY CAUTIONS
•Before installation work, read thoroughly this “Safety Cautions” to install the air conditioner correctly.
•This “Safety Cautions” describes the important contents concerned to the safety. Be sure to keep in mind these items. Symbols and meanings are as described below.
WARNING Indicates “User may be seriously injured (*1) if it is incorrectly used.”
CAUTION |
Indicates “It is assumed that user may be injured (*2) or property damage (*3) may occur if it is incorrectly used.” |
*1: “Serious injury” means a disease which has an after-effect or requires hospitalization or long-term going to the hospital for treatment, such as loss of sight, burn (by high temperature or low temperature), electric shock, fracture, poisoning, etc.
*2: “Injury” means hurt, burn, electric shock, etc. which does not require hospitalization or long-term going to the hospital for treatment. *3: “Property damage” means enlarged damage concerned to house, household effects, domestic animal, pet, etc.
Explanation of symbols
indicates prohibition (prohibited action).
The concrete prohibited action is indicated with sentence in or near the symbol.
indicates that the forced instructed action (Act necessarily).
The concrete instructed action is indicated with sentence in or near the symbol.
indicates an item with care.
The concrete item to be cautioned is indicated with sentence in or near the symbol.
WARNING CAUTION
•Keep all plastic bags away from babies and small children as a danger of suffocation exists.
•Install the suction grille securely to the main unit. If an incomplete installation is performed, falling of the suction grille may causes an injury.
Specifications
High-Efficiency Filter |
TCB- |
TCB- |
TCB- |
TCB- |
|
(65%) model name |
UFM11BE |
UFM21BE |
UFM31BE |
UFM41BE |
|
|
MMD- |
MMD- |
MMD- |
MMD- |
|
|
AP0071BH |
AP0151BH |
AP0241BH |
AP0361BH |
|
Conformed air |
to |
to |
to |
to |
|
AP0121BH |
AP0181BH |
AP0301BH |
AP0561BH |
||
conditioner model |
|||||
|
|
|
RAV- |
||
name |
|
RAV- |
RAV- |
||
|
SM1101BT to |
||||
|
|
||||
|
— |
SM561BT, |
SM801BT, |
SM1401BT, |
|
|
|
SM562BT |
SM802BT |
SM1102BT to |
|
|
|
|
|
SM1402BT |
|
Quantity |
1 |
1 |
2 |
2 |
|
|
|
|
|
|
|
Dust collecting effect |
65% (NBS Colorimetric method) |
||||
|
|
|
|
|
|
Operation time (Life) |
|
2500 hours |
|
||
|
|
|
|
|
High-Efficiency Filter |
TCB- |
TCB- |
TCB- |
TCB- |
|
(90%) model name |
UFM51BE |
UFM61BE |
UFM71BE |
UFM81BE |
|
|
MMD- |
MMD- |
MMD- |
MMD- |
|
|
AP0071BH |
AP0151BH |
AP0241BH |
AP0361BH |
|
Conformed air |
to |
to |
to |
to |
|
AP0121BH |
AP0181BH |
AP0301BH |
AP0561BH |
||
conditioner model |
|||||
|
|
|
RAV- |
||
name |
|
RAV- |
RAV- |
||
|
SM1101BT to |
||||
|
|
—SM561BT, SM801BT, SM1401BT, SM562BT SM802BT SM1102BT to
|
|
|
|
SM1402BT |
Quantity |
1 |
1 |
2 |
2 |
|
|
|
||
Dust collecting effect |
|
90% (NBS Colorimetric method) |
||
|
|
|
|
|
Operation time (Life) |
|
1800 hours |
|
1
Installation of High-Efficiency Filter
This filter is used for underside intake only.
In case of using MMD-AP** , install the filter kit for underside (TCB-FK***BE) be fore install this filter.
1 Mount the attached filter fixture plate.
Loose the fixing screw of the blower base at once, insert the filter fixture plate from width and fasten together with the blower base. "AP0071~AP0181, SM561 and SM562" attaches one piece for the filter fixture plate, and "AP0241~AP0561, SM801~SM1401 and SM802~SM1402" attaches two pieces.
NOTE
SM561, SM562,
AP0071~AP0181
Filter fixture plate |
Blower base |
SM801~SM1401
SM802~SM1402
AP0241~AP0561
Tighten the fixing screw of the blower base certainly after attaching the filter fixture plate.
When fixing is not enough, it becomes the cause of generating, such as a noise.
Blower base
Filter fixture plate
2 Remove the air filter, and install High-Efficiency Filter to the inlet port.
Push the High-Efficiency Filter completely up to the end. Check that the rear side is hanged to the hook.
Adjust the hook with plier if fixing of hook is not enough.
Indoor unit
3 Install the air filter
Be sure to fix the air filter with clamps in order to prevent falling. (Clamps are attached to the indoor unit.)
NOTE
These filter cannot be reused even if it is washed.
High-Efficiency
Filter
Hook
High-Efficiency Filter
Air filter