Toshiba RAS-10SKHP-ES, RAS-13SKHP-ES2, RAS-18SKHP-ES, RAS-24SKHP-ES2 SERVICE MANUAL

4 (2)

FIXED SPEED

Engineering

RAS-10, 18SKHP-ES &

 

Databook

RAS-13, 24SKHP-ES2

 

 

 

TCTC 09-004

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Contents

Specifications

3

Dimensions of Indoor and outdoor units

4

Wiring Diagram

12

Sensible Capacity Table

16

Part Load Performance

18

Air Speed Distribution

22

Sound Characteristics (NC Curve)

26

- 2 -

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical specifications Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

RAS-10S2AH-ES

RAS-13S2AH-ES2

 

RAS-18S2AH-ES

 

RAS-24S2AH-ES2

 

 

Indoor unit

 

 

 

 

RAS-10SKHP-ES

RAS-13SKHP-ES2

 

RAS-18SKHP-ES

 

RAS-24SKHP-ES2

 

 

Cooling capacity

kW

 

2.73

3.75

5.11

 

6.80

 

 

Power input (min. -rated - max)

kW

C

0,83-0,84-0,85

1,14-1,17-1,19

1,54-1,55-1,58

 

2,03-2,05-2,10

 

 

EER

W/W

 

3.25

3.21

3.30

 

3.32

 

 

Energy efficiency class

 

C

 

 

A

A

 

A

 

A

 

 

Annual energy consumption

KWh

 

420

585

775

 

1025

 

 

Heating capacity

kW

 

2.94

4.20

5.49

 

7.30

 

 

Power input (min. -rated - max)

kW

H

0,79-0,81-0,82

1,14-1,16-1,18

1,47-1,50-1,53

 

1,93-1,96-2,05

 

 

COP

W/W

 

3.63

3.62

3.66

 

3.72

 

 

Energy efficiency class

 

H

 

 

A

A

 

A

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

RAS-10SKHP-ES

RAS-13SKHP-ES2

 

RAS-18SKHP-ES

 

RAS-24SKHP-ES2

 

 

Air Flow (max)

m3/h - l/s

C

510 - 142

600 - 167

1000 - 278

 

1240 - 344

 

 

Sound pressure level (l/m/h)

dB(A)

C

31/35/39

31/35/41

35/39/44

 

40/46/50

 

 

Sound power level (h)

dB(A)

C

52

54

57

 

63

 

 

Air Flow (max)

m3/h - l/s

H

560 - 156

620 - 172

1000 - 278

 

1240 - 344

 

 

Sound pressure level (l/m/h)

dB(A)

H

31/35/39

31/35/41

35/39/44

 

40/46/50

 

 

Sound power level (h)

dB(A)

H

52

54

57

 

63

 

 

Dimensions (h x w x d)

mm

 

 

 

250 x 740 x 195

275 x 790 x 205

 

320 x 1050 x 228

 

320 x 1050 x 228

 

 

Weight

kg

 

8.0

9.0

13.0

 

14.0

 

 

Outdoor unit

 

 

 

 

RAS-10S2AH-ES

RAS-13S2AH-ES2

 

RAS-18S2AH-ES

 

RAS-24S2AH-ES2

 

 

Air Flow

m3/h - l/s

 

2090 - 581

2160 - 600

2475 - 688

 

4100 - 1139

 

 

Sound pressure level (h)

dB(A)

C

48

51

57

 

57

 

 

Sound power level (h)

dBA

C

61

64

70

 

70

 

 

Operating range

°C

C

15-43

15-43

15-43

 

15-43

 

 

Sound pressure level (h)

dB(A)

H

48

51

58

 

58

 

 

Sound power level (h)

dBA

H

61

64

71

 

71

 

 

Operating range

°C

H

-10/24

-10/24

-10/24

 

-10/24

 

 

Dimensions (h x w x d)

mm

 

 

 

550 x 780 x 290

550 x 780 x 290

 

715 x 780 x 290

 

890 x 900 x 320

 

 

Weight

kg

 

31

34

47

 

64

 

 

Compressor type

 

 

 

 

Rotary

Rotary

 

Rotary

 

Rotary

 

 

Flare connection

 

 

 

 

 

 

 

 

 

 

 

 

Gas

in

 

3/8

1/2

1/2

 

1/2

 

 

Liquid

in

 

1/4

1/4

1/4

 

1/4

 

 

Minimum pipe length

m

 

2

2

3

 

3

 

 

Maximum pipe length

m

 

10

15

20

 

25

 

 

Maximum height difference

m

 

5

6

8

 

10

 

 

Chargeless pipe length

m

 

10

15

15

 

15

 

 

Power supply

V-ph-Hz

 

220-240/1/50

220-240/1/50

220-240/1/50

 

220-240/1/50

 

 

Filter

 

 

 

 

Toshiba New IAQ Filter x 2

 

Toshiba New IAQ Filter x 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C = cooling mode

H = heating mode

- 3 -

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Dimensions of Indoor and outdoor units

Indoor Unit: RAS-10SKHP-ES

- 4 -

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Outdoor Unit: RAS-10S2AH-ES

- 5 -

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Indoor Unit: RAS-13SKHP-ES2

- 6 -

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Outdoor Unit: RAS-13S2AH-ES2

- 7 -

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Indoor Unit: RAS-18SKHP-ES

- 8 -

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Outdoor Unit: RAS-18S2AH-ES

- 9 -

Toshiba RAS-10SKHP-ES, RAS-13SKHP-ES2, RAS-18SKHP-ES, RAS-24SKHP-ES2 SERVICE MANUAL

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Indoor Unit: RAS-24SKHP-ES2

- 10 -

FIXED SPEED: RAS-10, 18SKHP-ES & RAS-13, 24SKHP-ES2

Outdoor Unit: RAS-24S2AH-ES2

- 11 -

Loading...
+ 23 hidden pages