Toshiba RAS-10GKHP-ES2, RAS-10GKP-ES2 SERVICE MANUAL

0 (0)

FILE NO. SVM-06039-2

SERVICE MANUAL

AIR CONDITIONER

SPLIT WALL TYPE

RAS-10GKHP-ES2 / RAS-10GAH-ES2

RAS-10GKP-ES2 / RAS-10GA-ES2

RAS-10GKHP-AS2 / RAS-10GAH-AS2

RAS-10GKP-AS2 / RAS-10GA-AS2

June 2006

FILE NO. SVM-06039-2

CONTENTS

1.SPECIFICATIONS

2.CONSTRUCTION VIEWS

2-1 Indoor Unit

2-2 Outdoor Unit

3.WIRING DIAGRAM

3-1 RAS-10GKHP-ES2 / RAS-10GAH-ES2 3-2 RAS-10GKHP-AS2 / RAS-10GAH-AS2

3-3 RAS-10GKP-ES2 / RAS-10GA-ES2 3-4 RAS-10GKP-AS2 / RAS-10GA-AS2

4.SPECIFICATION OF ELECTRICAL PARTS

4-1 Indoor Unit (RAS-10GKHP-ES2, RAS-10GKHP-AS2) 4-2 Outdoor Unit (RAS-10GAH-ES2, RAS-10GAH-AS2)

4-3 Indoor Unit (RAS-10GKP-ES2, RAS-10GKP-AS2) 4-4 Outdoor Unit (RAS-10GA-ES2, RAS-10GA-AS2)

5.REFRIGERATION CYCLE DIAGRAM

5-1 RAS-10GKHP-ES2 / RAS-10GAH-ES2, RAS-10GKHP-AS2 / RAS-10GAH-AS2

5-2 RAS-10GKP-ES2 / RAS-10GA-ES2, RAS-10GKP-AS2 / RAS-10GA-AS2

6.CONTROL BLOCK DIAGRAM

6-1 RAS-10GKHP-ES2 / RAS-10GAH-ES2,

RAS-10GKHP-AS2 / RAS-10GAH-AS2 6-2 RAS-10GKP-ES2 / RAS-10GA-ES2,

RAS-10GKP-AS2 / RAS-10GA-AS2

7.OPERATION DESCRIPTION

7-1 Outline of Air Conditioner Control

7-2 Description of Operation Circuit

7-3 Hi POWER Mode

7-4 High-Temperature Limit Control

7-5 Low-Temperature Limit Control

7-6 Defrost Operation

7-7 Current Limit Control

7-8 Auto Restart Function

7-9 Self-Cleaning function

7-10 QUIET Mode

7-11 COMFORT SLEEP mode

1

FILE NO. SVM-06039

8.INSTALLATION PROCEDURE

8-1 Safety Cautions

8-2 Installation Diagram of Indoor and Outdoor Units 8-3 Installation

8-4 Indoor Unit

8-5 Outdoor Unit

8-6 How to Set Remote Control Selector Switch 8-7 Others

9.TROUBLESHOOTING CHART

9-1 Troubleshooting Procedure

9-2 Basic Check Items

9-3 Primary Judgement

9-4 Self-Diagnosis by Remote Control (Check Code) 9-5 Troubleshooting Flowcharts

9-6 Troubleshooting for Remote Control (Including The Indoor P.C. Board)

10.PARTS REPLACEMENT

10-1 Indoor Unit

10-2 Outdoor Unit

11.EXPLODED VIEWS AND PARTS LIST

11-1 Indoor Unit (E-Parts Assy) (For RAS-10GKHP-ES2, RAS-10GKP-ES2) 11-2 Indoor Unit (E-Parts Assy) (For RAS-10GKHP-AS2, RAS-10GKP-AS2)

11-3 Indoor Unit

11-4 Outdoor Unit (RAS-10GAH-ES2, RAS-10GNAH-AS2)

11-5 Outdoor Unit (RAS-10GA-ES2, RAS-10GA-AS2)

This air conditioner is charged with

HFC (R410A) that doesn't deplete the Ozone layer.

This air conditioner requires special installation for the refrigerant R410A.

2

FILE NO. SVM-06039

1. SPECIFICATIONS

 

MODEL

 

RAS-10GKHP-ES2 / RAS-10GAH-ES2

 

RAS-10GKP-ES2 / RAS-10GA-ES2

 

 

 

 

 

RAS-10GKHP-AS2 / RAS-10GAH-AS2

 

RAS-10GKP-AS2 / RAS-10GA-AS2

ITEM

 

 

 

 

Cooling

 

Heating

 

Cooling

 

 

Capacity

 

 

 

220V

 

240V

 

220V

 

240V

220V

 

240V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

2.73

 

2.73

 

2.92

 

2.96

2.73

 

2.73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

 

 

 

 

1

 

 

 

 

 

Power source

 

 

V

 

 

 

 

220 240

 

 

 

 

 

 

 

 

Hz

 

 

 

50

 

 

 

 

 

Power consumption

kW

0.83

 

0.85

 

0.79

 

0.82

0.83

 

0.85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

%

98

 

97

 

97

 

96

98

 

97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running

Indoor

A

 

 

 

0.15

 

 

 

 

 

current

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor

A

3.71

 

3.50

 

3.55

 

3.40

3.71

 

3.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting current

A

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture removal

lit/h

 

 

 

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noise

Indoor (H/M/L)

dB

 

 

 

39/35/31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor (220-240V)

dB

47

 

49

 

47

 

49

46

 

47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant

Name of refrigerant

 

 

 

 

 

R410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated amount

kg

 

 

 

0.78

 

 

0.72

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side size

mm

 

 

 

 

9.52

 

 

 

 

 

 

Connection type

 

 

 

 

 

Flare connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid side size

mm

 

 

 

 

6.35

 

 

 

 

 

Interconnection

Connection type

 

 

 

 

 

Flare connection

 

 

 

 

pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum length

m

 

 

 

10*1

 

 

 

 

 

 

(One way)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum height

m

 

 

 

5

 

 

 

 

 

 

difference

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR UNIT

 

 

RAS-10GKHP-ES2

 

 

RAS-10GKP-ES2

 

 

RAS-10GKHP-AS2

 

 

RAS-10GKP-AS2

 

 

 

 

 

 

Height

mm

 

 

250

 

 

Dimensions

 

 

 

 

 

 

 

Width

mm

 

 

740

 

 

 

 

 

 

 

 

 

 

 

Depth

mm

 

 

185

 

 

 

 

 

 

 

 

 

 

Net weight

 

kg

 

 

8

 

 

 

 

 

 

 

 

 

Evaporator type

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

Indoor fan type

 

 

 

 

Cross flow fan

 

 

 

 

 

 

 

 

 

 

High fan

m3/h

540

 

560

 

540

Air volume

Medium fan

m3/h

460

 

480

 

460

 

Low fan

m3/h

380

 

390

 

380

Fan motor output

W

 

 

20

 

 

 

 

 

 

 

 

 

Air filter

 

 

Honeycomb woven filter with PP frame

 

OUTDOOR UNIT

 

 

 

RAS-10GAH-ES2

 

 

RAS-10GA-ES2

 

 

 

RAS-10GAH-AS2

 

 

RAS-10GA-ES2

 

 

 

 

 

 

 

 

 

 

 

Height

mm

 

 

 

 

 

550

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions Width

mm

 

 

 

 

 

780

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

mm

 

 

 

 

 

290

 

 

 

Net weight

 

 

kg

 

 

 

31

 

 

 

30

Condenser type

 

 

 

 

 

Finned tube

 

 

 

Outdoor fan type

 

 

 

 

 

Propeller fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow volume

 

 

m3/h

2030

 

2150

 

2030

 

2150

1740

 

1850

Fan motor output

W

 

 

 

30

 

 

 

20

Compressor

 

Model

 

 

 

 

 

PA108X1C-4FZDN

 

 

 

 

Output

W

 

 

 

 

 

750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety device

 

 

 

 

 

 

 

Fuse, Overload relay

 

 

 

Louver type

 

 

 

 

 

 

 

Automatic louver

 

 

 

Usable outdoor temperature range

°C

15 ~ 43

 

 

 

10 ~ 24

 

15 ~ 43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

FILE NO. SVM-06039

Note : 1

Capacity is based on the following temperature conditions.

Temperature

Condition

 

JIS B8615-1

 

Cooling

Heating

Indoor unit inlet air temperature

(DB)

27°C

20°C

(WB)

19°C

15°C

 

Outdoor unit inlet air temperature

(DB)

35°C

7°C

(WB)

24°C

6°C

 

Note : 2

 

 

 

*1 No need to charge extra refrigerant.

4

Toshiba RAS-10GKHP-ES2, RAS-10GKP-ES2 SERVICE MANUAL

FILE NO. SVM-06039

2. CONSTRUCTION VIEWS

2-1. Indoor Unit

160

57 18 Wireless remote control

(Flare 9.52)

– 5 –

 

 

 

 

 

 

 

 

FILE NO. SVM-06039

 

2-2. Outdoor Unit

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

28

109

124

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

 

50

R15

 

 

 

 

 

 

 

 

 

 

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

307

 

 

 

 

 

321

86

 

 

 

321

 

 

321

307

 

Ø6 hole

 

 

 

 

 

 

 

 

 

R5.5

 

 

 

 

Ø6 hole

 

 

 

 

 

 

 

 

 

 

 

36

R15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ø11x14 hole

A detail Drawing (Back leg)

 

 

 

 

50

 

Ø25 Drain outlet

2- Ø11 x 14

Hole

 

 

 

 

 

 

 

 

B Detail Drawing (Front leg)

 

 

 

 

 

(For Ø8 -Ø10 anchor bolt)

 

 

 

 

550

290

FAN-GUARD

 

 

 

Ø 436

 

 

 

275

 

 

 

90

600

90

69

321

342

COVER-PV

Z

 

 

Electrical part cover

 

 

Liquid side

 

 

(Flare Ø6.35)

 

 

Gas side

 

 

(Flare Ø9.52)

129

84

5

4

 

Z View

Service port

 

600

 

45 or more

 

Air intlel

 

 

600 or more

321

 

 

100 or more

Air outlel

400 or more

 

 

 

 

4x Ø11 Long holes(For Ø8Ø10 anchor bolt)

Installation dimension

6

FILE NO. SVM-06039-2

3. WIRING DIAGRAM

3-1. RAS-10GKHP-ES2 / RAS-10GAH-ES2

 

 

 

 

 

 

 

 

73 C x2

LOUVER

 

 

INFRARED RAYS RECEIVE

 

 

 

 

 

 

 

THERMAL FUSE

MOTOR

 

 

AND INDICATION PARTS

 

 

 

 

 

 

 

 

 

 

 

 

CN25 1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

PINK

PINK

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

YEL YEL YEL YEL WHI

BLU

BLU

BLU

BLU

BLU

BLU

BLU WHI

 

 

 

 

 

 

 

1 2

 

 

 

 

 

5 4 3 2 1

1 2 3 4

5 6

7 8

 

 

 

 

 

 

 

1 2 CN04

 

 

 

5 4 3 2 1

1 2 3 4

5 6 7 8 CN14

 

BLK

 

 

 

 

 

 

 

 

 

CN07

 

 

 

 

 

 

 

 

 

 

 

P04

 

SG01

R22

 

 

 

 

 

 

 

 

 

 

 

 

 

Micro

 

 

 

 

 

 

 

 

 

 

 

 

DC5V

 

 

 

 

 

 

 

 

L

BRW

 

 

DSA

VARISTOR

 

 

 

 

 

Voltage

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regulator

 

 

 

Module

 

 

N

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN & YEL

 

 

 

3

 

 

T6.3A 250VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

CN31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO

 

 

 

 

 

R319

 

 

 

 

SINGLE PHASE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1S

C01

C02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2

I

 

 

 

 

 

 

 

+

220-240V 50/60Hz

 

 

 

 

 

 

 

 

VAR

 

 

 

 

 

 

 

 

 

 

 

RY01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L01

 

 

 

R26

 

 

DB01

 

C63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

CR03

 

 

 

 

R25

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

8

 

 

 

IC03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAIN P.C. BOARD

 

 

D3

 

 

 

 

 

 

 

 

T02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WP-009

 

 

 

 

R27

 

 

 

 

 

C.T.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY03

 

RY04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

C15

 

 

 

 

 

 

WHI

 

 

 

 

 

 

CR02

 

 

 

 

 

 

 

3

1

CN11

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

CN10 5

1

2 3

 

 

 

 

 

 

 

 

 

 

135 C

 

 

BLK

5

3

1

1 2 3

 

 

 

 

 

 

 

 

 

 

 

 

1 1

 

3 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 2

GRY

 

 

 

 

 

 

 

CN27

CN03

 

 

CN01

 

 

 

 

 

YEL

 

 

 

 

 

 

 

 

 

CR01

 

 

 

 

3 3

BRWRED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2

THERMO

 

1

2

HEAT EXCHANGER

 

4 4

 

 

 

 

 

 

 

 

 

1 2

 

1

2

 

5 5

 

 

 

 

 

 

 

 

 

 

 

SENSOR (TA)

SENSOR (TC)

 

 

 

6 6

WHI

 

 

 

 

 

 

 

 

 

BLK BLK

 

 

BLK

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC FAN MOTOR

 

 

 

 

 

 

 

INDOOR

BLK

WHI

RED

BLU

 

TERMINAL

 

1

2

3

4

 

BLOCK

INDOOR

 

 

 

 

OUTDOOR

OUTDOOR

 

 

 

 

 

TERMINAL

 

 

 

 

 

BLOCK

1(L) 2(N)

3

4

CHASSIS

BLK

 

BLK

BLK

 

 

 

 

 

 

 

 

 

SOLENOID COIL

 

 

OVERLOAD RELAY

 

RED

CAPACITOR

 

BLK

RED

RED

 

WHI BLK

 

 

 

 

 

COMPRESSOR

 

FAN

 

 

MOTOR

 

PNK

CAPACITOR

 

 

 

WHI

 

7

FILE NO. SVM-06039-2

3-2. RAS-10GKHP-AS2 / RAS-10GAH-AS2

 

 

 

 

 

 

 

 

73 C x2

LOUVER

 

 

INFRARED RAYS RECEIVE

 

 

 

 

 

 

 

THERMAL FUSE

MOTOR

 

 

AND INDICATION PARTS

 

 

 

 

 

 

 

 

 

 

 

 

CN25 1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

PINK

PINK

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

YEL YEL YEL YEL WHI

BLU

BLU

BLU

BLU

BLU

BLU

BLU WHI

 

 

 

 

 

 

 

1 2

 

 

 

 

 

5 4 3 2 1

1 2 3 4

5 6

7 8

 

 

 

 

 

 

 

1 2 CN04

 

 

 

5 4 3 2 1

1 2 3 4

5 6 7 8 CN14

 

BLK

 

 

 

 

 

 

 

 

 

CN07

 

 

 

 

 

 

 

 

 

 

 

P04

 

SG01

R22

 

 

 

 

 

 

 

 

 

 

 

 

 

Micro

 

 

 

 

 

 

 

 

 

 

 

 

DC5V

 

 

 

 

 

 

 

 

BRW

 

 

 

DSA

VARISTOR

 

 

 

 

 

Voltage

 

 

 

Power

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

Regulator

 

 

 

Module

DC12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN & YEL

 

 

 

3

 

 

T6.3A 250VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

CN31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO

 

 

 

 

 

R319

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1S

C01

C02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2

I

 

 

 

 

 

 

 

+

 

 

 

 

 

 

RY01

 

 

 

VAR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L01

 

 

 

R26

 

 

DB01

 

C63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

CR03

 

 

 

 

R25

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

8

 

 

 

IC03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAIN P.C. BOARD

 

 

D3

 

 

 

 

 

 

 

 

T02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SINGLE PHASE

 

 

 

 

 

 

 

WP-009

 

 

 

 

R27

 

 

 

 

C.T.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220-240V 50/60Hz

 

 

RY03

 

RY04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

C15

 

 

 

 

 

 

WHI

 

 

 

 

 

 

CR02

 

 

 

 

 

 

 

3

1

CN11

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

CN10 5

1

2 3

 

 

 

 

 

 

 

 

 

 

135 C

 

 

BLK

5

3

1

1 2 3

 

 

 

 

 

 

 

 

 

 

 

 

1 1

 

3 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 2

GRY

 

 

 

 

 

 

 

CN27

CN03

 

 

CN01

 

 

 

 

 

YEL

 

 

 

 

 

 

 

 

 

CR01

 

 

 

 

3 3

BRWRED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2

THERMO

 

1

2

HEAT EXCHANGER

 

4 4

 

 

 

 

 

 

 

 

 

1 2

 

1

2

 

5 5

 

 

 

 

 

 

 

 

 

 

 

SENSOR (TA)

SENSOR (TC)

 

 

 

6 6

WHI

 

 

 

 

 

 

 

 

 

BLK BLK

 

 

BLK

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC FAN MOTOR

 

 

 

 

 

 

 

INDOOR

BLK

WHI

RED

BLU

 

TERMINAL

 

1

2

3

4

 

BLOCK

INDOOR

 

 

 

 

OUTDOOR

OUTDOOR

 

 

 

 

 

TERMINAL

 

 

 

 

 

BLOCK

1(L) 2(N)

3

4

CHASSIS

BLK

 

BLK

BLK

 

 

 

 

 

 

 

 

 

SOLENOID COIL

 

 

OVERLOAD RELAY

 

RED

CAPACITOR

 

BLK

RED

RED

 

WHI BLK

 

 

 

 

 

COMPRESSOR

 

FAN

 

 

MOTOR

 

PNK

CAPACITOR

 

 

 

WHI

 

8

FILE NO. SVM-06039-2

3-3. RAS-10GKP-ES2 / RAS-10GA-ES2

BLK

P04

L BRW

N BLU

GRN & YEL

CN31 SINGLE PHASE

220-240V 50/60Hz

CN03

1 2

1 2

BLK

BLK

WHI

 

 

73 C x2

LOUVER

 

 

 

INFRARED RAYS RECEIVE

 

 

THERMAL FUSE

MOTOR

 

 

 

AND INDICATION PARTS

 

 

 

 

 

 

CN25 1

2

3

4 5

6

7

8

 

 

 

PINK

PINK

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

YEL YEL YEL YEL

WHI

BLU

BLU

BLU

BLU

BLU

BLU

BLU

WHI

 

 

 

1 2

 

 

5 4 3 2 1

1 2 3 4 5 6

7 8

CN14

 

1 2 CN04

 

 

5 4 3 2 1

1 2 3 4 5 6 7 8

 

 

 

 

 

CN07

 

 

 

 

 

 

 

 

 

 

 

SG01

R22

 

 

 

 

 

 

 

 

 

 

 

Micro

 

 

DSA

VARISTOR

 

 

 

DC5V

Voltage

 

 

 

Power

 

 

 

 

 

 

 

 

 

Regulator

 

 

 

Module

 

DC12V

 

3

T6.3A 250VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1STO

C01

 

C02

 

 

 

R319

 

 

 

 

 

 

RY01

2

VARI

 

 

 

 

 

 

 

 

 

+

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L01

 

 

 

R26

 

 

DB01

C63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

MAIN P.C. BOARD

CR03

 

R25

 

IC03

 

3

 

WP-009

 

8

 

 

 

D

 

 

 

 

 

R27

BLK

 

 

 

 

 

 

 

 

 

 

C15

 

 

 

CN11

 

 

 

 

 

 

CN10

5

3

1

1

2

3

 

 

 

 

135 C

1

BLK

5

3

1

1 2 3

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

2

2

GRY

 

 

 

 

 

 

 

CN01

 

3

3

YEL

 

 

 

 

 

 

THERMO

1

2

HEAT EXCHANGER

4 4

BRWRED

 

 

 

 

 

 

1

2

5

5

 

 

 

 

 

 

 

SENSOR (TA)

SENSOR (TC)

6

6

WHI

 

 

 

 

 

 

 

BLK

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC FAN MOTOR

 

 

 

 

 

 

INDOOR

1

2

TERMINAL

BLOCK

BLK

WHI

 

OUTDOOR

TERMINAL

BLOCK

1(L) 2(N)

GRN&YEL

INDOOR

OUTDOOR

CHASSIS

 

 

 

RED

 

BLK

BLK

RED

CAPACITOR

CAPACITOR

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

RED

WHI

COMPRESSOR

OVERLOAD RELAY

RED

WHI

8-(1)

FILE NO. SVM-06039-2

3-4. RAS-10GKP-AS2 / RAS-10GA-AS2

BLK

P04

BRW

BLU

GRN & YEL

CN31

SINGLE PHASE 220-240V 50/60Hz

CN03

1 2

1 2

BLK

BLK

WHI

 

 

73 C x2

LOUVER

 

 

 

INFRARED RAYS RECEIVE

 

 

THERMAL FUSE

MOTOR

 

 

 

AND INDICATION PARTS

 

 

 

 

 

 

CN25 1

2

3

4 5

6

7

8

 

 

 

PINK

PINK

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

YEL YEL YEL YEL

WHI

BLU

BLU

BLU

BLU

BLU

BLU

BLU

WHI

 

 

 

1 2

 

 

5 4 3 2 1

1 2 3 4 5 6

7 8

CN14

 

1 2 CN04

 

 

5 4 3 2 1

1 2 3 4 5 6 7 8

 

 

 

 

 

CN07

 

 

 

 

 

 

 

 

 

 

 

SG01

R22

 

 

 

 

 

 

 

 

 

 

 

Micro

 

 

DSA

VARISTOR

 

 

 

DC5V

Voltage

 

 

 

Power

 

 

 

 

 

 

 

 

 

Regulator

 

 

 

Module

 

DC12V

 

3

T6.3A 250VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1STO

C01

 

C02

 

 

 

R319

 

 

 

 

 

 

RY01

2

VARI

 

 

 

 

 

 

 

 

 

+

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L01

 

 

 

R26

 

 

DB01

C63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

MAIN P.C. BOARD

CR03

 

R25

 

IC03

 

3

 

WP-009

 

8

 

 

 

D

 

 

 

 

 

R27

BLK

 

 

 

 

 

 

 

 

 

 

C15

 

 

 

CN11

 

 

 

 

 

 

CN10

5

3

1

1

2

3

 

 

 

 

135 C

1

BLK

5

3

1

1 2 3

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

2

2

GRY

 

 

 

 

 

 

 

CN01

 

3

3

YEL

 

 

 

 

 

 

THERMO

1

2

HEAT EXCHANGER

4 4

BRWRED

 

 

 

 

 

 

1

2

5

5

 

 

 

 

 

 

 

SENSOR (TA)

SENSOR (TC)

6

6

WHI

 

 

 

 

 

 

 

BLK

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC FAN MOTOR

 

 

 

 

 

 

INDOOR

1

2

TERMINAL

BLOCK

BLK

WHI

 

OUTDOOR

TERMINAL

BLOCK

1(L) 2(N)

GRN&YEL

INDOOR

OUTDOOR

CHASSIS

 

 

 

RED

 

BLK

BLK

RED

CAPACITOR

CAPACITOR

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

RED

WHI

COMPRESSOR

OVERLOAD RELAY

RED

WHI

8-(2)

FILE NO. SVM-06039

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-10GKHP-ES2, RAS-10GKHP-AS2)

No.

Parts name

Type

Specifications

1

Fan motor (for indoor)

MMF-240-20-4B

AC Motor with 135°C thermo fuse

 

 

 

 

2

Thermo sensor (TA-sensor)

 

10kΩ at 25°C

 

 

 

 

3

Micro power module (M01)

μRM1260V

 

 

 

 

 

4

Microcontroller unit (IC30)

TMP87CM40AFG-6G61

 

5

Heat exchanger sensor

 

10kΩ at 25°C

 

(TC-sensor)

 

 

 

 

 

 

 

 

6

Line filter (L01)

LC*SS11V-06270

27mH, 600mA

 

 

 

 

7

Bridge rectifier (DB01)

D3SBA60

4A, 600V

 

 

 

 

8

Capacitor (C63)

EKMH401VSN470MP20S

47μF, 400V

 

 

 

 

9

Fuse (F01)

BET6.3A

T6.3A, 250VAC

 

 

 

 

10

Varistor (R21, R22)

TND15G-561KB0SLAA0

560V

 

 

 

 

11

Resistor (R319)

RF-2TK5R6

5.6Ω, 2W

 

 

 

 

12

Louver motor

MP24ZT

12VDC

 

 

 

 

13

Relay (Comp., RY01)

G4A-1A-E

Rating 20A/AC250V, 12VDC

 

 

 

 

14

Relay (Fan, RY03)

G5NB-1A

Rating 3A/AC250V, 12VDC

15

Relay (Solenoide, RY04)

G5NB-1A

Rating 3A/AC250V, 12VDC

4-2. Outdoor Unit (RAS-10GAH-ES2,RAS-10GAH-AS2)

No.

Parts name

Type

Specifications

 

 

 

 

Output (Rated) 750W , 2poles, 1 phase, 220 240V, 50Hz

1

Compressor

 

 

 

 

PA108X1C-4FZDN

Winding resistance (Ω)

C-R

C-S

 

 

 

(at 20°C)

 

 

 

 

 

3.75

4.75

 

 

 

 

 

 

 

 

 

Output (Rated) 30W, 6poles, 1 phase, 220 240V, 50Hz

 

 

 

 

 

 

2

Fan motor (for outdoor)

WLF-240-30A

Winding resistance (Ω)

Red-Black

White-Black

 

 

 

(at 20°C)

237

380

3

Running capacitor

DS451155NPQB

AC 450V~, 1.5μF

 

 

(for fan motor)

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Running capacitor

RS44B256U0213S

AC 440V~, 25μF

 

 

(for compressor)

 

 

 

 

 

 

 

5

Solenoid coil

AC 220 240V

 

 

(for 4-way valve)

 

 

 

 

 

 

 

6

Overload relay

LPAP960B

U/T: 6.1A(80°C), Open: 135±5°C, Clse: 75±11°C

 

 

 

 

 

 

9

FILE NO. SVM-06039

4-3. Indoor Unit (RAS-10GKP-ES2, RAS-10GKP-AS2)

No.

Parts name

Type

Specifications

 

 

 

 

1

Fan motor (for indoor)

MMF-240-20-4B

AC Motor with 135°C thermo fuse

2

Thermo sensor (TA-sensor)

 

10kΩ at 25°C

 

 

 

 

3

Micro power module (M01)

μRM1260V

 

4

Microcontroller unit (IC30)

TMP87CM40AFG-6G61

 

 

 

 

 

5

Heat exchanger sensor

 

10kΩ at 25°C

 

(TC-sensor)

 

 

 

 

 

 

 

 

6

Line filter (L01)

*SS11V-06270

27mH, 600mA

 

 

 

 

7

Bridge rectifier (DB01)

D3SBA60

4A, 600V

8

Capacitor (C63)

EKMH401VSN470MP20S

2200μF, 25V

 

 

 

 

9

Fuse (F01)

BET6.3A

6.3A, 250VAC

 

 

 

 

10

V

TND15G-561KB0SLAA0

560V

aristor (R21, R22)

11

Louver motor

MP24T

12VDC

12

Relay (Comp., RY01)

G4A-1A-E

Rating 25A/AC250V, 3~48VDC

4-4. Outdoor Unit (RAS-10GA-ES2, RAS-10GA-AS2)

No.

Parts name

Type

Specifications

 

 

 

 

Output (Rated) 750W, 2poles, 1 phase, 220 240V, 50Hz

1

Compressor

 

 

 

 

PA108X1C-4FZDN

Winding resistance (Ω)

C-R

C-S

 

 

 

(at 20°C)

 

 

 

 

 

3.75

4.75

 

 

 

 

 

 

 

 

 

Output (Rated) 20W, 6poles, 1 phase, 220 240V, 50Hz

 

 

 

 

 

 

2

Fan motor (for outdoor)

SKF-240-20B

Winding resistance (Ω)

Red-Black

White-Black

 

 

 

(at 20°C)

 

 

 

 

 

235.2

260.1

 

 

 

 

 

 

3

Running capacitor

DS451155NPQB

AC 450V~,1.5 μF

 

 

(for fan motor)

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Running capacitor

RS44B256U0213S

AC 440V~,25 μF

 

 

(for compressor)

 

 

 

 

 

 

 

 

 

 

 

5

Overload relay

LPAP960B

U/T: 6.1A(80°C), Open: 135±5°C, Clse: 75±11°C

 

 

 

 

 

 

10

5. REFRIGERATION CYCLE DIAGRAM FILE NO. SVM-06039

5-1. RAS-10GKHP-ES2 / RAS-10GAH-ES2 RAS-10GKHP-AS2 / RAS-10GAH-AS2

 

 

 

Indoor unit

T1

 

 

 

 

 

Cooling

Heat exchanger

 

 

 

 

0.39m

 

Heating

 

0.49m

(Connecting pipe)

 

(Connecting pipe)

 

 

9.52

 

 

Cross flow fan

6.35

 

 

 

 

O.D.:9.52mm

P

 

O.D.:6.35mm

 

Packed valve

 

Packed valve

 

( 9.52)

 

( 6.35)

 

Heating

 

 

Cooling

4-way valve

 

Capillary tube

 

 

 

 

 

 

1.5x1200l

Heating

Cooling Compressor

PA108X1C-4FZDN

 

 

 

 

Capillary tube

 

Accumulator

1.5x1000l

 

 

 

 

Heat exchanger

 

 

 

 

Refrigerant

 

Propeller fan

 

R410A : 0.78 kg.

Cooling

Outdoor unit

Mark(

)means check points of Gas Leak.

Heating

 

 

 

 

 

Standar d

Surface temp. of heat

 

Ambient temp.

 

 

Fan speed

conditions DB/WB

 

50Hz

pressure P

exchanger inter changing

(indoor)

 

(°C)

 

 

(MPaG)

pipe T1 (°C)

 

 

 

 

 

 

 

Indoor

 

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

2.95

43.5

High

20/15

 

7/6

Heating

 

 

 

 

 

 

 

Overload

3.70

57.0

Low

27/

 

24/18

 

 

 

 

 

 

 

 

 

Low temperature

2.40

32.0

High

20/

 

10/10

 

 

 

 

 

 

 

 

 

Standard

0.93

10.5

High

27/19

 

35/24

Cooling

 

 

 

 

 

 

 

Overload

1.08

15.0

High

32/23

 

43/26

 

 

 

 

 

 

 

 

 

Low temperature

0.69

2.0

Low

21/15

 

21/15

 

 

 

 

 

 

 

 

Note :

Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)

11

FILE NO. SVM-06039

5-2. RAS-10GKP-ES2 / RAS-10GA-ES2 RAS-10GKP-AS2 / RAS-10GA-AS2

 

 

Indoor unit

T1

 

 

 

 

Cooling

Heat exchanger

 

 

 

 

0.39m

 

 

0.49m

(Connecting pipe)

 

(Connecting pipe)

9.52

 

Cross flow fan

6.35

 

 

 

O.D.:9.52mm

P

 

O.D.:6.35mm

 

Packed valve

 

Packed valve

 

( 9.52)

 

( 6.35)

Cooling

Cooling Compressor

PA108X1C-4FZDN

Heat exchanger

Capillary tube 1.5x1100l

 

 

 

Refrigerant

 

Propeller fan

 

R410A : 0.72 kg.

Cooling

Outdoor unit

Mark(

)means check points of Gas Leak.

 

 

Standard

Surface temp. of heat

 

Ambient temp.

 

 

Fan speed

conditions DB/WB

 

50Hz

pressure P

exchanger interchanging

(indoor)

 

(°C)

 

 

(MPaG)

pipe T1 (°C)

 

 

 

 

 

 

 

Indoor

 

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

0.95

10.5

High

27/19

 

35/24

Cooling

 

 

 

 

 

 

 

Overload

1.12

16.0

High

32/23

 

43/26

 

 

 

 

 

 

 

 

 

Low temperature

0.71

2.0

Low

21/15

 

21/15

 

 

 

 

 

 

 

 

Note :

Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)

12

FILE NO. SVM-06039

6. CONTROL BLOCK DIAGRAM

6-1. RAS-10GKHP-ES2 / RAS-10GAH-ES2, RAS-10GKHP-AS2 / RAS-10GAH-AS2

Heat Exchange sensor

Thermo. Sensor

Current Sensor

(Compressor Current)

Infrared Rays Signal Reciver

Main Unit Control Panel

M.C.U.

Functions

 

 

Operation

Louver Control

Display

 

3-minutes Delay at Restart

for Compressor Timer

Display

Initiallizing Circuit Motor Revolution Control

Clock Frequency

Oscillator Circuit

Power Supply

Circuit

Noise Filter

Indoor Fan Processing Motor

(Temperature Processing) Timer

Compressor

 

 

Outdoor Fan

 

4-Way Valve

 

 

 

 

 

 

 

 

Louver

 

 

 

ON/OFF

 

 

ON/OFF

 

 

ON/OFF

 

 

ON/OFF

 

 

Signal

 

 

Signal

 

 

Signal

 

 

Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louver

 

 

 

Relay Driver, Louver Driver

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay

Relay

Relay

RY01

RY03

RY04

220-240 V~, 50Hz

 

 

Compressor

 

Outdoor Fan Motor

 

4-Way Valve

REMOTE CONTROL

 

 

 

 

Infrared Rays

 

Remote Control

 

 

 

 

 

 

Operation ( )

 

 

 

 

 

 

 

Operation Mode Selection

 

 

 

 

 

 

 

AUTO, COOL, DRY, HEAT, FAN ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON TIMER Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF TIMER Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louver Auto Swing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louver Direction Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hi power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIMER 1.3.5.9H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMFORT SLEEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QUIET

 

 

 

 

 

 

 

13

FILE NO. SVM-06039

6-2. RAS-10GKP-ES2 / RAS-10GA-ES2, RAS-10GKP-AS2 / RAS-10GA-AS2

Heat Exchange sensor

Thermo. Sensor

Infrared Rays Signal Reciver

220-240 V~, 50Hz

REMOTE CONTROL

Main Unit Control Panel

 

 

 

 

 

 

M.C.U.

 

 

 

 

 

 

 

 

 

 

 

 

 

Functions

 

 

 

Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louver Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

3-minutes Delay at Restart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sign Display

 

Initiallizing Circuit

 

 

 

 

 

Motor Revolution Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock Frequency

 

 

 

 

 

Processing

 

 

 

 

 

Oscillator Circuit

 

 

 

 

 

(Temperature Processing)

 

 

 

Indoor Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

 

 

Compressor

 

 

Louver

 

 

 

Circuit

 

 

 

 

 

ON/OFF

 

 

ON/OFF

 

 

 

 

 

 

 

 

 

 

 

Signal

 

 

Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noise Filter

 

 

 

 

 

 

Relay Driver, Louver Driver

 

 

 

Louver

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY01

 

 

 

 

Compressor, Outdoor Fan Motor

Infrared Rays

Remote Control

Operation ()

Operation Mode Selection

AUTO, COOL, DRY, FAN ONLY

Temperature Setting

Fan Speed Selection

ON TIMER Setting

OFF TIMER Setting

Louver Auto Swing

Louver Direction Setting

ECO

Hi power

TIMER 1.3.5.9H

COMFORT SLEEP

QUIET

14

FILE NO. SVM-06039

7. OPERATION DESCRIPTION

7-1. Outline of Air Conditioner Control

This is a fixed capacity type air conditioner, which uses AC motor for an indoor fan. The AC motor drive

circuit is mounted in the indoor unit. And electrical parts which driving the compressor and the outdoor fan motor, are mounted in the outdoor unit.

The air conditioner is controlled by the controller mounted in the indoor unit. The controller operates all components based on the commands transmitted from the remote control and the feedback data of the sensor is as follow:

The temperature measurement at the air inlet of the indoor heat exchanger by the indoor temperature sensor

The temperature measurement at the indoor heat exchanger by the indoor heat exchanger temperature sensor

Indoor fan motor operation control

Louver motor control

LED display control

Outdoor fan motor operation control

4-WAYS-VALVE operation control

(Heat pump model only)

Compressor operation control

Receiving the information of the operation status and judging the information or the indication of errors

7-1-1. Louver control

(1)Vertical air flow louver

Position of veritcal air flow louver is automatically controlled according to the operation mode. Besides, position of vertical air flow louver can be arbitrarily set by pressing [FIX] button.

The louver position which is set by [FIX] button is stored in the microcontroller, and the louver is automatically set at the stored position for the next operation.

(2)Swing

If [SWING] button is pressed when the indoor unit is in operation, the vertical air flow louver starts swinging. When [SWING] button is pressed again, it stops swinging.

7-1-2. Indoor fan control (AC Fan motor)

(1)The indoor fan is operated by the stepless speed change AC motor.

(2)For air flow level, speed of the indoor fan motor is controlled in five steps (LOW, LOW+, MED, MED+ and HIGH). If AUTO mode is selected, the fan motor speed is automatically controlled by the difference between the preset temperature and the room temperature.

LOW+ = LOW+MED 2

MED+ = MED+HIGH 2

Table 7-1-1

 

 

 

 

 

 

 

 

FAN TAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

 

UH

H

 

M

 

 

 

 

L

L-

UL

SL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATION

Fan only

 

 

 

H

 

M

 

 

 

 

L

L-

 

 

 

 

 

MODE

Dry

 

 

 

 

 

M

 

 

 

 

L

L-

UL

 

SL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat

UH

H

 

 

M

 

L

 

L-

 

 

UL

 

 

 

SL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAS-10GK Series

rpm

1350

 

1300

1180

1140

1000

 

980

 

900

800

750

700

550

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air flow volume (m3/h)

560

 

540

500

460

400

 

390

 

350

300

270

250

180

 

 

 

 

RAS-10GKH Series

rpm

1350

 

1300

1180

1140

1000

 

980

 

900

800

750

700

550

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air flow volume (m3/h)

560

 

540

500

460

400

 

390

 

350

300

270

250

180

 

 

 

 

 

15

7-2. Description of Operation Circuit

(1)When turning on the breaker, the operation lamp blinks. This means that the power supply is on.

(2) When pressing [ ] button on the remote control, receiving beep sounds from the indoor unit, and the next operation is performed together with opening the vertical air flow louver.

(3)Once the operation mode is set, it is memorized in the microcontroller so that the previous operation can be effected thereafter simply by pressing

[

] button.

7-2-1. Fan only operation

([MODE] button on the remote control is set to the fan only operation.)

(1)When [FAN] button is set to AUTO, the indoor fan motor operates as shown in Fig. 7-2-1. When [FAN] button is set to LOW, LOW+, MED, MED+ or HIGH, the motor operates with a constant air flow.

FILE NO. SVM-06039

7-2-2. Cooling operation

([MODE] button on the remote control is set to the cooling operation.)

(1)The compressor, 4-way valve, outdoor fan and operation display on the remote control are controlled as shown in Fig. 7-2-2.

-(Presettemp.)

 

°C

 

 

 

 

 

 

 

 

ON

 

ON

 

 

 

 

0.5

 

 

temp.)

 

OFF

OFF

OFF ON

(Room

 

 

 

 

 

Preset

 

0

 

 

 

 

 

temp.

 

Compressor

valveway-4

fanOutdoor OPERATION

 

 

 

 

 

 

display

 

 

 

 

 

temp.)

 

°C

 

 

+3

 

 

 

 

(Preset

 

M+

+2.5

 

 

*1

 

 

 

-

+2

 

*1

temp.)

+1.5

 

 

*1

 

 

 

(Room

+1

 

L-

+0.5

 

 

 

 

 

Preset

 

0

 

 

 

 

 

temp.

 

 

 

 

 

 

 

(Preset temp.: 22°C)

 

NOTE :

 

 

 

 

 

 

 

 

*1: The values marked with *1 are calculated and controlled by the difference in motor speed between M+ and L-.

(2)The Hi POWER, ECO and COMFORT SLEEP operation cannot be set.

Fig. 7-2-1 Setting of air flow [FAN:AUTO]

Fig. 7-2-2

(2)When [FAN] button is set to AUTO, the indoor fan motor operates as shown in Fig. 7-2-3. When [FAN] button is set to LOW, LOW+, MED, MED+ or HIGH, the motor operates with a constant air flow.

temp.)

 

°C

 

+3

M+

 

(Preset

+2.5

 

 

 

 

+2

*1

 

 

 

*1

temp.)

+1.5

*1

 

 

(Room

+1

 

+0.5

L-

 

 

 

Preset

 

0

 

 

 

temp.

-0.5

 

 

 

NOTE :

*1: The values marked with *1 are calculated and controlled by the difference in motor speed between M+ and L-.

Fig. 7-2-3 Setting of air flow [FAN:AUTO]

- 16 -

7-2-3. Dry operation

([MODE] button on the remote control is set to the dry operation.)

(1)The compressor, 4-way valve, outdoor fan and operation display on the remote control are controlled as shown in Fig. 7-2-4.

-(Presettemp.)temp.)

°C

ON:5min.ON:6min. OFF:5min.OFF:4min.

 

ON:5min.ON:6min. OFF:5min.OFF:4min.

 

+3

 

 

 

 

 

 

 

 

+2

 

OFF

 

ON

(Room

+1

 

 

 

 

 

 

OFF

 

OFF

 

 

 

 

 

 

Preset

 

0

 

 

 

 

 

 

 

 

OPERATION

temp.

 

 

Compressor

valveway-4

fanOutdoor

 

 

 

 

 

 

 

 

 

display

 

 

 

 

 

 

 

Fig. 7-2-4

(2)The microcontroller turns the compressor on and off at the regular intervals (4 to 6 minutes). While the compressor is turning off, the indoor fan motor operates in the SUPER LOW position.

The pattern of operation depending on the relation between room temperature and preset temperatures is shown in Fig. 7-2-5.

Room temp.

Preset temp.+1

Preset temp.

Compressor

ON

 

ON

ON

ON

 

 

 

 

 

 

 

 

Outdoor fan

 

OFF

 

 

OFF

 

OFF

 

 

 

 

 

 

 

Indoor fan

 

*SL

 

L

 

 

 

 

L

 

SL

L

SL

L

 

*Super Low

 

 

 

 

 

 

Fig. 7-2-5

(3)[FAN] button on the remote control is set to AUTO only.

(4)The Hi POWER, ECO, COMFORT SLEEP and QUIET operations cannot be set.

FILE NO. SVM-06039

7-2-4. Heating operation *Heat pump model only ([MODE] button on the remote control is set to the heating operation.)

(1)The compressor, 4-way valve, outdoor fan and operation display on the remote control are controlled as shown in Fig. 7-2-6.

Preset

 

°C

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

temp.

 

 

 

 

 

 

 

 

temp.)

 

 

 

 

OFF ON

OFF

ON

(Preset

-0.5

 

 

 

 

 

 

-

 

 

ON

 

ON

 

 

 

 

 

 

 

(Roomtemp.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

way-4 valve

Outdoorfan

OPERATION

 

 

 

 

 

 

 

 

display

Fig. 7-2-6

(2)When [FAN] button is set to AUTO, the indoor fan motor operates as shown in Fig. 7-2-7. When [FAN] button is set to LOW, LOW+, MED, MED+ or HIGH, the motor operates with a constant air flow.

°C

Preset

 

0

L

 

temp.

-0.5

 

temp.)

-1

*1

-1.5

 

*2

 

-2

(Preset

 

 

 

M+

temp.)-

-5.0

 

(Room

-5.5

H

[FAN AUTO]

 

 

 

*1, *2 : The values marked with *1 and *2 are calculated and controlled by the difference in motor speed between M+ and L.

Fig. 7-2-7 Setting of air flow [FAN:AUTO]

- 17 -

(3)The indoor heat exchanger restricts revolving speed of the fan motor to prevent a cold draft. The upper limit of the revolving speed is shown in Fig. 7-2-8 and Table 7-2-1.

Indoor heat exchanger temperature

10GKH Series

°C

43 32

42 31

32 21

31 20

*2 A+4 A+4 A8 A8

*6 *5

Manual

AUTO (One of 5 steps)

*4

L- H (Up to

 

seting speed)

SL*3

 

SL*1

 

Stop

 

Fig. 7-2-8 Cold draft preventing control

NOTES :

*1: The fan stops for 2 minutes after thermostat-OFF.

*2: A is 24°C when the preset temperature is 24°C or more and A is the preset temperature when it is under 24 °C.

*3: SL means Super Low.

*4: Calculated from difference in motor speed between SL and H.

FILE NO. SVM-06039

*5 and *6:

Table 7-2-1

Fan

*5

*6

speed

Starting period

Stabilized period

 

 

 

AUTO

· Up until 12 minutes

· From 12 to 25 minutes

 

passed after starting

passed after starting

 

the unit

the unit and room

 

· From 12 to 25 minutes

temperature is

 

passed after starting

between preset

 

the unit and room

temperature and 3 °C

 

temperature is 3 °C

lower than preset

 

lower than preset

temperature

 

· temperature

· 25 minutes or more

 

 

passed after starting

 

 

the unit

 

 

 

Manual

· Room temperature

· Room temperature

(L - H)

< Preset temperature

Preset temperature

 

- 4 °C

-3.5 °C

7-2-5. Automatic operation

([MODE] button on the remote control is set to the automatic operation.)

(1)One of 3 operations (Cooling, Fan only or Heating) is selected according to difference between the preset temperature and the room temperature at which the automatic operation has started, as shown in Fig. 7-2-9. The Fan only operation continues until the room temperature reaches a level at which another mode is selected.

(2)Temporary Auto

When the [RESET] button on the indoor unit

is pushed, the preset temperature is fixed at 24 °C and the indoor unit is controlled as shown in

Fig. 7-2-9.

 

°C

Cooling operation

 

 

 

 

The louver moves to the position same

 

+4

as Hi POWER operation.

temp.)

Cooling operation

 

 

 

(Preset

0

 

 

 

Fan only operation

 

-

-1

 

 

 

temp.)

 

 

 

Heating operation

 

 

 

(Room

 

 

 

 

 

GKH Series

 

GK Series

 

 

 

 

 

 

 

 

 

 

 

Fig. 7-2-9

- 18 -

7-3. Hi POWER Mode

([Hi POWER] button on the remote control is pressed.)

When [Hi POWER] button is pressed while the indoor unit is in Auto, Cooling or Heating operation, Hi POWER mark is indicated on the display of the remote control and the unit operates as follows.

(1) Automatic operation

· The indoor unit operates in according to the current operation.

(2) Cooling operation

The setting temperature drops 3°C.

(The value of the setting temperature on the remote control does not change.)

If the room temperature is higher than the setting temperature by 3.5°C or more, the horizontal louver moves to the Hi POWER position automatically. Then when the room temperature is 1°C less than the setting temperature the horizontal louver returns automatically.

FAN speed : [AUTO]

If the room temperature is higher than the setting temperature by 3.5°C or more, the air conditioner operates at maximum airflow level. If the room temperature is higher than the setting temperature by less than 3.5°C, the air conditioner operates at normal airflow level.

FAN speed : One of 5 levels

If the room temperature is higher than the setting temperature by 3.5°C or more, the air conditioner operates at higher consecutive airflow level. If the room temperature is higher than the setting temperature by less than 3.5°C, the air conditioner operates at normal airflow level.

(3) Heating operation (GKH Series only)

·

The preset temperature increases 2°C, (The value of the preset temperature on the remote control does not change.)

·The indoor unit operates in normal heating mode except the preset temperature is higher (+2°C).

(4)The Hi POWER mode can not be set in Dry or Fan only operation.

FILE NO. SVM-06039

7-4. High-Temperature Limit Control *Heat pump model only

The microcontroller detects the indoor heat exchanger temperature to prevent pressure of a refrigerating cycle from increasing excessively.

The compressor and outdoor fan motor are controlled as shown in Fig. 7-4-1.

Compressor

Outdoor fan

Heat exchanger

temp.

 

 

OFF

OFF

(°C)

60

 

 

ON

OFF

53

 

 

ON

ON

52

 

Fig. 7-4-1

7-5. Low-Temperature Limit Control

The microcontroller detects the indoor heat exchanger temperature to prevent the indoor heat exchanger from freezing.

The compressor and outdoor fan motor are controlled as shown in Fig. 7-5-1 and 7-5-2.

Heat exchanger

 

temperature

Compressor Outdoor fan

(°C)

ON

5

Less than 2°C continues

 

2

for 5 minutes

OFF

 

Fig. 7-5-1

- 19 -