Ventilation Planning Guide
For THERMADOR PROFESSIONAL Ranges,
Rangetops, and Hoods
Guide de Planification de Ventilation
Pour les cuisinières, surface de cuisson, et hottes
PROFESSIONAL de THERMADOR
Guía de Planificación de Ventilación
Para las estufas, placas de cocción, y campanas PROFESSIONAL de THERMADOR
Models | Modèles |
Modelos:
PRO GRAND DUAL
FUEL RANGES
PRO GRAND GAS
RANGES
PRO HARMONY DUAL FUEL RANGES
PRO HARMONY GAS RANGES
PRO RANGETOPS
PRO WALL HOODS
PRO CHIMNEY
HOODS
PRO CUSTOM
INSERT HOODS
Ventilation Planning Guide
It is recommended that a THERMADOR PROFESSIONAL hood is used with a THERMADOR PROFESSIONAL range or rangetop. The following range and rangetop ventilation combinations are approved installations.
All blower models referenced may not be compatible with all hoods referenced. Refer to www.thermador.com for a complete selection of ventilation options, blowers, and accessories.
IMPORTANT NOTES:
•See related Thermador Manuals for additional information.
•Thermador recommends not exceeding 50 ft. (15.24 m) equivalent length of duct.
•Keep duct runs as short and straight as possible. Elbows and transitions fittings reduce air flow efficiency. Back to back elbows and “S” turns give very poor delivery and are not recommended. A short straight length of duct at the inlet of a remote blower gives the best delivery.
•For Thermador Pro Ranges applications with a non-approved Thermador hood. The hood and/or blower must be rated for 1 CFM for every 100 BTU on the Range/Rangetop.
•If the range has a 12'' Griddle, add an additional 200 CFM to the estimated blower capacity.
•If the range has a 24'' Griddle, add an additional 400 CFM to the estimated blower capacity.
•If the range has a Grill, add an additional 400 CFM to the estimated blower capacity.
•If the range has a Grill and a Griddle, add an additional 600 CFM to the estimated blower capacity.
•For island applications, it is recommended to use a hood width that exceeds the width of the range by 6'' (152 mm), overlapping the range or rangetop by a minimum of 3'' (76 mm) on each end.
•A 25 foot extension cable (EXTNCB25) is available for purchase to connect the hood to in-line or remote blowers, if required.
English | 1 |
Range hoods with selectable blowers:
Range or Rangetop |
Recommended |
Min. Integral |
Min. In-Line or |
Other Available |
Model |
Hood Models |
Blower |
Remote Blower |
Blowers |
|
|
|
|
|
NOTE – All Range/Hood/Blower combinations below must use minimum 6" diameter duct. |
|
|||
|
|
|
|
|
30'' |
PH30HS |
VTN630* |
VTI610* |
N/A |
|
|
|
VTR630* |
|
|
|
|
|
|
NOTE – All Range/Hood/Blower combinations below must use minimum 8" diameter duct. |
|
|||
|
|
|
|
|
30'' |
PH30HS, HPCN36NS, PH36GS, |
VTN1030* |
VTI1010* |
VTR1330* |
|
PH36HS, VCIN36JP |
VTN1090* |
VTR1030* |
VTN1080* |
|
|
|
|
|
36'' without Grill or Griddle |
HPCN36NS, PH36GS, PH36HS, |
|
|
|
36'' with Griddle |
VCIN36JP, PH42GS, HPCN48NS, |
|
|
|
|
PH48GS, PH48HS, VCIN48JP |
|
|
|
|
|
|
|
|
48'' with Griddle only |
HPCN48NS, PH48GS, PH48HS, |
|
|
|
|
VCIN48JP, PH54GS, VCIN54JP |
|
|
|
|
|
|
|
|
NOTE – All Range/Hood/Blower Combinations below must use minimum 10" diameter duct. |
|
|||
|
|
|
|
|
36'' with Grill |
HPCN36NS, PH36GS, PH36HS, |
VTN1030* |
VTI1010* |
VTR1330* |
|
VCIN36JP, PH42GS, HPCN48NS, |
VTN1090* |
VTR1030* |
VTN1080* |
|
PH48GS, PH48HS, VCIN48JP |
|
|
|
48'' with Grill |
HPCN48NS, PH48GS, PH48HS, |
|
|
|
48" with Grill and Griddle |
VCIN48JP, PH54GS, VCIN54JP |
|
|
|
|
VCIN60RP, PH60GS |
VTN1090* |
|
|
60" with Grill and Griddle |
VCIN60RP, PH60GS |
VTN1090* |
|
|
60" with Double Griddle |
|
|
|
|
* Indicates a letter designating the release year.
Range hoods with blower included:
Range or Rangetop Model |
Recommended Hood Models |
|
|
NOTE – All Range/Hood/Blower combinations below must use minimum 6" diameter duct. |
|
|
|
30'' |
HPWB30FS |
|
|
NOTE – All Range/Hood/Blower combinations below must use minimum 8" diameter duct. |
|
|
|
30'' |
HPCB36NS, HPWB36FS, VCIB36JP |
36'' without Grill or Griddle |
HPCB36NS, HPWB36FS, VCIB36JP, HPCB48NS, HPWB48FS, VCIB48JP |
36'' with Griddle |
|
48'' with Griddle only |
HPCB48NS, HPWB48FS, VCIB48JP, VCIB54JP |
NOTE – All Range/Hood/Blower Combinations below must use minimum 10" diameter duct. |
|
|
|
36'' with Grill |
HPCB36NS, HPWB36FS, VCIB36JP, HPWB48FS, VCIB48JP |
|
|
48'' with Grill |
HPCB48NS, HPWB48FS, VCIB48JP, VCIB54JP |
48" with Grill and Griddle |
|
|
|
English | 2 |