Telefunken TSOP5256, TSOP5240, TSOP5238, TSOP5237, TSOP5236 Datasheet

...
0 (0)

TSOP52..

Vishay Telefunken

Photo Module for High Data Rates PCM Remote Control Systems

Available types for different carrier frequencies

Type

fo

Type

fo

TSOP5230

30 kHz

TSOP5233

33 kHz

TSOP5236

36 kHz

TSOP5237

36.7 kHz

TSOP5238

38 kHz

TSOP5240

40 kHz

TSOP5256

56 kHz

 

 

 

 

 

 

Description

The TSOP52.. ± series are miniaturized SMD±IR Receiver Modules for infrared remote control systems. PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as IR filter.

The demodulated output signal can directly be decoded by a microprocessor. TSOP52.. is the standard IR remote control SMD±Receiver series, supporting all major transmission codes.

16797

Features

 

Photo detector and preamplifier in one package

Low power consumption

 

Internal filter for PCM frequency

High immunity against ambient light

 

Continuous data transmission possible

Suitable burst length 10 cycles/burst

 

TTL and CMOS compatibility

Taping available for topview and sideview

 

Output active low

assembly

 

Block Diagram

 

 

 

4

VS

Input

 

Control

 

 

 

 

 

Circuit

 

 

 

 

30 k

 

 

 

 

 

PIN

 

 

3

OUT

 

 

 

 

 

AGC

Band

Demodu-

 

 

Pass

lator

 

 

 

 

 

 

 

1

GND

 

 

 

 

 

 

 

 

16798

DocumentNumber 82154

www.vishay.com

Rev. 1, 08-Mar-01

1 (8)

TSOP52..

Vishay Telefunken

Absolute Maximum Ratings

Tamb = 25_C

 

 

 

 

Parameter

Test Conditions

Symbol

Value

Unit

Supply Voltage

Pin 4

VS

±0.3...6.0

V

Supply Current

Pin 4

IS

5

mA

Output Voltage

Pin 3

VO

±0.3...6.0

V

Output Current

Pin 3

IO

15

mA

Junction Temperature

 

Tj

100

C

Storage Temperature Range

 

Tstg

±40...+85

C

Operating Temperature Range

 

Tamb

±25...+85

C

Power Consumption

Tamb 85 C

Ptot

50

mW

Basic Characteristics

Tamb = 25_C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

 

Test Conditions

Symbol

Min

Typ

Max

Unit

Supply Current

VS = 5 V, Ev = 0

 

 

 

 

ISD

0.8

1.1

1.5

mA

 

VS = 5 V, Ev = 40 klx, sunlight

 

ISH

 

1.4

 

mA

Supply Voltage

 

 

 

 

 

 

 

 

 

 

VS

4.5

 

5.5

V

Transmission Distance

Ev = 0, test signal see fig.7,

 

d

 

30

 

m

 

IR diode TSAL6200, IF = 400 mA

 

 

 

 

 

 

Output Voltage Low (Pin 3)

IOSL = 0.5 mA,Ee = 0.7 mW/m2

VOSL

 

 

250

mV

Irradiance (30±40 kHz)

Pulse width tolerance:

 

Ee min

 

0.5

0.6

mW/m2

 

tpi ± 5/fo < tpo < tpi + 6/fo,

 

 

 

 

 

 

Irradiance (56 kHz)

Ee min

 

0.6

0.7

mW/m2

test signal see fig.7

 

 

Irradiance

t

pi

± 5/f

< t

po

< t

pi

+ 6/f

o

E

e max

30

 

 

W/m2

 

 

o

 

 

 

 

 

 

 

 

Directivity

Angle of half transmission distance

ϕ1/2

 

±50

 

deg

Application Circuit

 

4

100 *)

+5V

 

4.7 mF *)

 

TSOP52..

 

 

 

>10 k

 

 

 

 

TSAL62..

 

optional

mC

3

 

 

 

 

**)

 

 

2

 

 

N.C.

 

 

 

 

 

1

 

 

16799

 

 

GND

 

 

 

*) recommended to suppress power supply disturbances

**) the output voltage should not be hold continuously at a voltage below 3.3V by the external circuit.

www.vishay.com

DocumentNumber 82154

2 (8)

Rev. 1, 08-Mar-01

Telefunken TSOP5256, TSOP5240, TSOP5238, TSOP5237, TSOP5236 Datasheet

TSOP52..

Vishay Telefunken

Suitable Data Format

The circuit of the TSOP52.. is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances.

The distinguishing mark between data signal and disturbance signal are carrier frequency, burst length and duty cycle.

The data signal should fullfill the following condition:

Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz).

Burst length should be 10 cycles/burst or longer.

After each burst which is between 10 cycles and 70 cycles a gap time of at least 14 cycles is necessary.

For each burst which is longer than 1.8ms a corresponding gap time is necessary at some time in the data stream. This gap time should be at least 4 times longer than the burst.

Up to 800 short bursts per second can be received continuously.

Some examples for suitable data format are:

NEC Code, Toshiba Micom Format, Sharp Code, RC5 Code, RC6 Code, R±2000 Code.

When a disturbance signal is applied to the TSOP52.. it can still receive the data signal. However the sensitivity is reduced to that level that no unexpected pulses will occure.

Some examples for such disturbance signals which are suppressed by the TSOP52.. are:

DC light (e.g. from tungsten bulb or sunlight)

Continuous signal at 38kHz or at any other frequency

Signals from fluorescent lamps with electronic ballast with high or low modulation (see Figure A or Figure B).

0

5

10

15

20

time [ms]

Figure A: IR Signal from Fluorescent Lamp with low Modulation

0

5

10

15

20

time [s]

Figure B: IR Signal from Fluorescent Lamp with high Modulation

DocumentNumber 82154

www.vishay.com

Rev. 1, 08-Mar-01

3 (8)