TSOP52..
Vishay Telefunken
Photo Module for High Data Rates PCM Remote Control Systems
Available types for different carrier frequencies
Type |
fo |
Type |
fo |
TSOP5230 |
30 kHz |
TSOP5233 |
33 kHz |
TSOP5236 |
36 kHz |
TSOP5237 |
36.7 kHz |
TSOP5238 |
38 kHz |
TSOP5240 |
40 kHz |
TSOP5256 |
56 kHz |
|
|
|
|
|
|
Description
The TSOP52.. ± series are miniaturized SMD±IR Receiver Modules for infrared remote control systems. PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as IR filter.
The demodulated output signal can directly be decoded by a microprocessor. TSOP52.. is the standard IR remote control SMD±Receiver series, supporting all major transmission codes.
16797
Features
|
Photo detector and preamplifier in one package |
Low power consumption |
|
Internal filter for PCM frequency |
High immunity against ambient light |
|
Continuous data transmission possible |
Suitable burst length ≥ 10 cycles/burst |
|
TTL and CMOS compatibility |
Taping available for topview and sideview |
|
Output active low |
assembly |
|
Block Diagram
|
|
|
4 |
VS |
Input |
|
Control |
|
|
|
|
|
||
|
Circuit |
|
|
|
|
|
30 k |
|
|
|
|
|
|
|
PIN |
|
|
3 |
OUT |
|
|
|
|
|
|
AGC |
Band |
Demodu- |
|
|
Pass |
lator |
|
|
|
|
|
||
|
|
|
1 |
GND |
|
|
|
|
|
|
|
|
|
16798 |
DocumentNumber 82154 |
www.vishay.com |
Rev. 1, 08-Mar-01 |
1 (8) |
TSOP52..
Vishay Telefunken
Absolute Maximum Ratings
Tamb = 25_C |
|
|
|
|
Parameter |
Test Conditions |
Symbol |
Value |
Unit |
Supply Voltage |
Pin 4 |
VS |
±0.3...6.0 |
V |
Supply Current |
Pin 4 |
IS |
5 |
mA |
Output Voltage |
Pin 3 |
VO |
±0.3...6.0 |
V |
Output Current |
Pin 3 |
IO |
15 |
mA |
Junction Temperature |
|
Tj |
100 |
C |
Storage Temperature Range |
|
Tstg |
±40...+85 |
C |
Operating Temperature Range |
|
Tamb |
±25...+85 |
C |
Power Consumption |
Tamb 85 C |
Ptot |
50 |
mW |
Basic Characteristics
Tamb = 25_C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Parameter |
|
|
|
Test Conditions |
Symbol |
Min |
Typ |
Max |
Unit |
||||||
Supply Current |
VS = 5 V, Ev = 0 |
|
|
|
|
ISD |
0.8 |
1.1 |
1.5 |
mA |
|||||
|
VS = 5 V, Ev = 40 klx, sunlight |
|
ISH |
|
1.4 |
|
mA |
||||||||
Supply Voltage |
|
|
|
|
|
|
|
|
|
|
VS |
4.5 |
|
5.5 |
V |
Transmission Distance |
Ev = 0, test signal see fig.7, |
|
d |
|
30 |
|
m |
||||||||
|
IR diode TSAL6200, IF = 400 mA |
|
|
|
|
|
|
||||||||
Output Voltage Low (Pin 3) |
IOSL = 0.5 mA,Ee = 0.7 mW/m2 |
VOSL |
|
|
250 |
mV |
|||||||||
Irradiance (30±40 kHz) |
Pulse width tolerance: |
|
Ee min |
|
0.5 |
0.6 |
mW/m2 |
||||||||
|
tpi ± 5/fo < tpo < tpi + 6/fo, |
|
|
|
|
|
|
||||||||
Irradiance (56 kHz) |
Ee min |
|
0.6 |
0.7 |
mW/m2 |
||||||||||
test signal see fig.7 |
|
|
|||||||||||||
Irradiance |
t |
pi |
± 5/f |
< t |
po |
< t |
pi |
+ 6/f |
o |
E |
e max |
30 |
|
|
W/m2 |
|
|
o |
|
|
|
|
|
|
|
|
|||||
Directivity |
Angle of half transmission distance |
ϕ1/2 |
|
±50 |
|
deg |
Application Circuit
|
4 |
100 *) |
+5V |
|
4.7 mF *) |
|
|
TSOP52.. |
|
|
|
|
>10 k |
|
|
|
|
|
|
TSAL62.. |
|
optional |
mC |
3 |
|
||
|
|
||
|
**) |
|
|
|
2 |
|
|
|
N.C. |
|
|
|
|
|
|
|
1 |
|
|
16799 |
|
|
GND |
|
|
|
*) recommended to suppress power supply disturbances
**) the output voltage should not be hold continuously at a voltage below 3.3V by the external circuit.
www.vishay.com |
DocumentNumber 82154 |
2 (8) |
Rev. 1, 08-Mar-01 |
TSOP52..
Vishay Telefunken
Suitable Data Format
The circuit of the TSOP52.. is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances.
The distinguishing mark between data signal and disturbance signal are carrier frequency, burst length and duty cycle.
The data signal should fullfill the following condition:
•Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz).
•Burst length should be 10 cycles/burst or longer.
•After each burst which is between 10 cycles and 70 cycles a gap time of at least 14 cycles is necessary.
•For each burst which is longer than 1.8ms a corresponding gap time is necessary at some time in the data stream. This gap time should be at least 4 times longer than the burst.
•Up to 800 short bursts per second can be received continuously.
Some examples for suitable data format are:
NEC Code, Toshiba Micom Format, Sharp Code, RC5 Code, RC6 Code, R±2000 Code.
When a disturbance signal is applied to the TSOP52.. it can still receive the data signal. However the sensitivity is reduced to that level that no unexpected pulses will occure.
Some examples for such disturbance signals which are suppressed by the TSOP52.. are:
•DC light (e.g. from tungsten bulb or sunlight)
•Continuous signal at 38kHz or at any other frequency
•Signals from fluorescent lamps with electronic ballast with high or low modulation (see Figure A or Figure B).
0 |
5 |
10 |
15 |
20 |
time [ms]
Figure A: IR Signal from Fluorescent Lamp with low Modulation
0 |
5 |
10 |
15 |
20 |
time [s]
Figure B: IR Signal from Fluorescent Lamp with high Modulation
DocumentNumber 82154 |
www.vishay.com |
Rev. 1, 08-Mar-01 |
3 (8) |