Telefunken TSOP4156, TSOP4140, TSOP4138, TSOP4137, TSOP4136 Datasheet

...
0 (0)
Telefunken TSOP4156, TSOP4140, TSOP4138, TSOP4137, TSOP4136 Datasheet

TSOP41..

Vishay Telefunken

Photo Modules for PCM Remote Control Systems

Available types for different carrier frequencies

Type

fo

Type

fo

TSOP4130

30 kHz

TSOP4133

33 kHz

TSOP4136

36 kHz

TSOP4137

36.7 kHz

 

 

 

 

TSOP4138

38 kHz

TSOP4140

40 kHz

 

 

 

 

TSOP4156

56 kHz

 

 

Description

 

The TSOP41.. ± series are miniaturized receivers for

 

infrared remote control systems. PIN diode and

 

preamplifier are assembled on lead frame, the epoxy

 

package is designed as IR filter.

 

The demodulated output signal can directly be

 

decoded by a microprocessor. The main benefit is the

 

reliable function even in disturbed ambient and the

 

protection against uncontrolled output pulses.

14 500

Features

 

D Photo detector and preamplifier in one package

D Low power consumption

D Internal filter for PCM frequency

D High immunity against ambient light

D Improved shielding against electrical field

D Enhanced data rate of 2400 bit/s

disturbance

D Operation with short bursts possible

D TTL and CMOS compatibility

(6 cycles/burst)

D Output active low

 

Block Diagram

 

 

 

3

Input

 

Control

VS

 

 

Circuit

30 kW

 

 

 

 

 

 

1

PIN

 

 

OUT

 

 

 

 

AGC

Band

Demodu-

 

Pass

lator

 

 

 

 

 

2

 

 

 

GND

9612226

 

 

 

Document Number 82135

www.vishay.com

Rev. 7, 29 Mar-01

1 (7)

TSOP41..

Vishay Telefunken

Absolute Maximum Ratings

Tamb = 25_C

Parameter

Test Conditions

Symbol

Value

Unit

Supply Voltage

(Pin 3)

VS

±0.3...6.0

V

Supply Current

(Pin 3)

IS

5

mA

Output Voltage

(Pin 1)

VO

±0.3...6.0

V

Output Current

(Pin 1)

IO

5

mA

Junction Temperature

 

Tj

100

°C

Storage Temperature Range

 

Tstg

±25...+85

°C

Operating Temperature Range

 

Tamb

±25...+85

°C

Power Consumption

(Tamb x 85 °C)

Ptot

50

mW

Soldering Temperature

t x 10 s, 1 mm from case

Tsd

260

°C

Basic Characteristics

Tamb = 25_C

Parameter

Test Conditions

 

 

Symbol

Min

Typ

Max

Unit

Supply Current (Pin 2)

VS = 5 V, Ev = 0

 

 

 

 

ISD

0.8

1.1

1.5

mA

 

VS = 5 V, Ev = 40 klx, sunlight

 

ISH

 

1.4

 

mA

Supply Voltage (Pin 2)

 

 

 

 

 

VS

4.5

 

5.5

V

Transmission Distance

Ev = 0, test signal see fig.8,

 

d

 

35

 

m

 

IR diode TSAL6200, IF = 250 mA

 

 

 

 

 

Output Voltage Low (Pin 1)

IOL = 0.5 mA,

 

 

 

 

VOL

 

 

250

mV

 

E = 0.7 mW/m2, f = f

o

 

 

 

 

 

 

 

 

 

e

 

 

 

 

 

 

 

 

Irradiance (30 ± 40 kHz)

Pulse width tolerance: t

pi

± 5/f

<

E

 

0.2

0.4

mW/m2

 

 

 

o

 

e min

 

 

 

 

 

tpo < tpi + 5/fo, test signal see fig.8

 

 

 

 

 

Irradiance (56 kHz)

Pulse width tolerance: t

pi

± 5/f

<

E

 

0.3

0.5

mW/m2

 

 

 

o

 

e min

 

 

 

 

 

tpo < tpi + 5/fo, test signal see fig.8

 

 

 

 

 

Irradiance

 

 

 

 

 

E

30

 

 

W/m2

 

 

 

 

 

 

e max

 

 

 

 

Application Circuit

 

 

100 W *)

+5V

TSOP41..

2

4.7 mF *)

 

 

 

 

>10 kW

 

 

 

 

TSAL62..

 

optional

mC

1

 

 

 

 

**)

 

 

 

 

16286

3

 

GND

 

 

 

 

 

*) recommended to suppress power supply disturbances

**) The output voltage should not be hold continuously at a voltage below 3.3V by the external circuit.

www.vishay.com

Document Number 82135

2 (7)

Rev. 7, 29-Mar 01

TSOP41..

Vishay Telefunken

Suitable Data Format

The circuit of the TSOP41.. is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances.

The distinguishing mark between data signal and disturbance signal are carrier frequency, burst length and duty cycle.

The data signal should fullfill the following condition:

Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz).

Burst length should be 6 cycles/burst or longer.

After each burst which is between 6 cycles and 70 cycles a gap time of at least 10 cycles is neccessary.

For each burst which is longer than 1.8ms a corresponding gap time is necessary at some time in the data stream. This gap time should have at least same length as the burst.

Up to 2200 short bursts per second can be received continuously.

Some examples for suitable data format are:

NEC Code, Toshiba Micom Format, Sharp Code, RC5 Code, RC6 Code, RCMM Code, R±2000 Code, RECS±80 Code.

When a disturbance signal is applied to the TSOP41.. it can still receive the data signal. However the sensitivity is reduced to that level that no unexpected pulses will occure.

Some examples for such disturbance signals which are suppressed by the TSOP41.. are:

DC light (e.g. from tungsten bulb or sunlight)

Continuous signal at 38kHz or at any other frequency

Signals from fluorescent lamps with electronic ballast (an example of the signal modulation is shown in the figure below).

0

5

10

15

20

time [ms]

IR Signal from Fluorescent Lamp with low Modulation