Telefunken TSOP2856ZC1, TSOP2840ZC1, TSOP2838ZC1, TSOP2837ZC1, TSOP2833ZC1 Datasheet

...
0 (0)

TSOP28..ZC1

Vishay Telefunken

Photo Modules for PCM Remote Control Systems

Available types for different carrier frequencies

Type

fo

Type

fo

TSOP2830ZC1

30 kHz

TSOP2833ZC1

33 kHz

TSOP2836ZC1

36 kHz

TSOP2837ZC1

36.7 kHz

 

 

 

 

TSOP2838ZC1

38 kHz

TSOP2840ZC1

40 kHz

 

 

 

 

TSOP2856ZC1

56 kHz

 

 

Description

The TSOP28..ZC1 ± series are miniaturized receivers for infrared remote control systems. PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as IR filter.

The demodulated output signal can directly be decoded by a microprocessor. The main benefit is the reliable function even in disturbed ambient and the protection against uncontrolled output pulses.

14 500

Features

DPhoto detector and preamplifier in one package

DInternal filter for PCM frequency

DTTL and CMOS compatibility

DOutput active low

DImproved shielding against electrical field disturbance

DSuitable burst length 6 cycles/burst

Special Features

DSmall size package

DEnhanced immunity against all kinds of disturbance light

DNo occurrence of disturbance pulses at the output

DShort settling time after power on (<200ms)

Block Diagram

 

 

 

2

Input

 

Control

VS

 

 

Circuit

30 kW

 

 

 

 

 

 

1

PIN

 

 

OUT

 

 

 

 

AGC

Band

Demodu-

 

Pass

lator

 

 

 

 

 

3

 

 

 

GND

14318

 

 

 

Document Number 82072

 

 

www.vishay.de FaxBack +1-408-970-5600

Rev. 4, 13-Jun-00

 

 

1 (7)

TSOP28..ZC1

Vishay Telefunken

Absolute Maximum Ratings

Tamb = 25_C

Parameter

Test Conditions

Symbol

Value

Unit

Supply Voltage

(Pin 2)

VS

±0.3...6.0

V

Supply Current

(Pin 2)

IS

5

mA

Output Voltage

(Pin 1)

VO

±0.3...6.0

V

Output Current

(Pin 1)

IO

5

mA

Junction Temperature

 

Tj

100

°C

Storage Temperature Range

 

Tstg

±25...+85

°C

Operating Temperature Range

 

Tamb

±25...+85

°C

Power Consumption

(Tamb x 85 °C)

Ptot

50

mW

Soldering Temperature

t x 10 s, 1 mm from case

Tsd

260

°C

Basic Characteristics

Tamb = 25_C

Parameter

Test Conditions

Symbol

Min

Typ

Max

Unit

Supply Current (Pin 2)

VS = 5 V, Ev = 0

 

ISD

0.9

1.2

1.5

mA

 

VS = 5 V, Ev = 40 klx, sunlight

ISH

 

1.3

 

mA

Supply Voltage (Pin 2)

 

 

VS

4.5

 

5.5

V

Transmission Distance

Ev = 0, test signal see fig.6,

d

 

35

 

m

 

IR diode TSAL6200, IF = 300 mA

 

 

 

 

 

Output Voltage Low (Pin 1)

IOL = 0.5 mA,

 

VOL

 

 

250

mV

 

E = 0.7 mW/m2, f = f

o

 

 

 

 

 

 

e

 

 

 

 

 

Irradiance (30 ± 40 kHz)

Pulse width tolerance:

E

 

0.3

0.5

mW/m2

 

tpi ± 4/fo < tpo < tpi + 6/fo,

e min

 

 

 

 

 

 

 

 

 

 

 

test signal see fig.6

 

 

 

 

 

 

Irradiance (56 kHz)

Pulse width tolerance:

E

 

0.4

0.7

mW/m2

 

tpi ± 4/fo < tpo < tpi + 6/fo,

e min

 

 

 

 

 

 

 

 

 

 

 

test signal see fig.6

 

 

 

 

 

 

Irradiance

 

 

E

30

 

 

W/m2

 

 

 

e max

 

 

 

 

Directivity

Angle of half transmission distance

ϕ1/2

 

±45

 

deg

Application Circuit

 

 

100 W *)

+5V

TSOP28..

2

4.7 mF *)

 

 

>10 kW

 

 

 

 

 

TSAL62..

 

 

optional

1

 

mC

 

 

 

 

 

3

GND

14319

*) recommended to suppress power supply disturbances

 

www.vishay.de FaxBack +1-408-970-5600

Document Number 82072

2 (7)

Rev. 4, 13-Jun-00

Telefunken TSOP2856ZC1, TSOP2840ZC1, TSOP2838ZC1, TSOP2837ZC1, TSOP2833ZC1 Datasheet

TSOP28..ZC1

Vishay Telefunken

Suitable Data Format

The circuit of the TSOP28..ZC1 is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances.

The distinguishing mark between data signal ( not suppressed) and disturbance signal (supressed) are carrier frequency, burst length and Signal Gap Time (see diagram below).

The data signal should fullfill the following condition:

Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz).

Burst length should be 6 cycles/burst or longer.

After each burst a gap time of at least 10 cycles is neccessary.

The data format should not make a continuous signal transmission. There must be a Signal Gap Time (longer than 15ms) at least each 90ms (see Figure A).

Some examples for suitable data format are:

NEC Code (repetitive pulse), NEC Code (repetitive data), Toshiba Micom Format, Sharp Code, RC5 Code, RECS±80 Code, R±2000 Code.

When a disturbance signal is applied to the TSOP28..ZC1 it can still receive the data signal. However the sensitivity is reduced to that level that no unexpected pulses will occure.

Some examples for such disturbance signals which are suppressed by the TSOP28..ZC1 are:

DC light (e.g. from tungsten bulb or sunlight),

Continuous signal at 38kHz or at any other frequency,

Signals from fluorescent lamps (see Figure B).

Continuous IR signal (e.g. 1ms burst, 2ms pause)

 

 

 

 

 

Signal Gap Time

 

 

 

 

0

10

20

30

40

50

60

70

80

90

100

 

 

 

 

 

time [ms]

 

 

 

 

 

Figure A: Data Signal (Output of IR Receiver) with a Signal Gap Time of 20ms

 

 

 

 

Signal Gap Time

 

 

 

 

 

0

2

4

6

8

10

12

14

16

18

20

 

 

 

 

 

time [ms]

 

 

 

 

 

Figure B: Disturbance Signal from Fluorescent Lamp with Signal Gap Time of 7ms (suppressed by TSOP28..)

Document Number 82072

www.vishay.de FaxBack +1-408-970-5600

Rev. 4, 13-Jun-00

3 (7)