The Snow Detector & Melting Control 665 is designed to control a single zone snow melting
system. The snow melting system may be started manually or automatically through the use
of a Snow/Ice Sensor 090. Standard features include pump/valve exercising, monitor menu
and many other useful items.
User Interface
User Access Level(s) The tekmar Snow Detector and Melting Control 665 has four access levels which are LT D (limited),
USER, INST (installer), and ADV (advanced). This brochure only covers the LTD (limited) and USER levels. Only qualified service people should make adjustments in the INST (installer) and ADV (advanced) access levels.
Item Field
Displays an abbreviated
name of the selected item
Menu Field
Displays the
current menu
Status Field
Displays the current
status of the control's
inputs, outputs and
operation
Number Field
Displays the current value
of the selected item
Melt Deman
Idle Deman
WW
W
Buttons
Selects Menus, Items and
adjusts settings
The tekmar Snow Detector & Melting Control 665 has a Liquid Crystal Display (LCD) and four push buttons
(Menu, Item, ▲, ▼) which are used to view and adjust the settings.
Heat
Displays when the Heat
Pump
Displays when the system pump is
operating.
Override
Displays when the control is in override
mode.
Warning
Displays when an error exists or when a
limit has been reached.
A Watts Water Technologies Company
relay is turned on.
1 of 4
°F °
C
min hr
sec
Lock / Unlock
Displays whether the access levels are
locked or unlocked.
Pointer
Displays the control operation as
indicated by the text.
All of the items displayed by the control are organized into various menus. These
menus are listed on the left hand side of the display (Menu Field). To select a
menu, use the Menu button. By pressing and releasing the Menu button, the
display will advance to the next available menu. Once a menu is selected, there
will be a group of items that can be viewed within that menu.
Item
The abbreviated name of the selected item will be displayed in the item field of
the display. To view the next available item, press and release the Item button.
Once you have reached the last available item in a menu, pressing and releasing
the Item button will return the display to the first item in the selected menu.
Adjust
To make an adjustment to a setting in the control, begin by selecting the
appropriate menu using the Menu button. Then select the desired item using the Item button. Finally, use the ▲ and / or ▼ button to make the adjustment.
Additional information can be gained by observing the Status field of the LCD. The
status field will indicate which of the control’s outputs are currently active. Most
symbols in the status field are only visible when the View menu is selected.
Depending on the settings the installer makes in the control, certain items may not appear.
Item
A Watts Water Technologies Company
Ltd
User
Current outdoor air temperature as measured by the outdoor sensor.
STRT, STOP,
IDLE, EXT,
0:00 to 23:59
hr, – – –, INF,
WWSD, CWCO,
DET
Page 3
Item
Ltd
User
665 Adjust Menu
The time for which the system is operated once it has reached its melting
temperature. This item cannot be viewed if a Remote Start/Stop Module
039 has been connected.
Sensitivity of water detection of the Snow/Ice Sensor 090.
Sensor 090 is present
The desired slab surface temperature while in the Melting Mode.
Ltd
User
665 Monitor Menu
The highest recorded outdoor air temperature since this item was last
cleared. To clear this item, press and hold the ▲ and ▼ buttons.
The lowest recorded outdoor air temperature since this item was last
cleared.To clear this item, press and hold the ▲ and ▼ buttons.
The highest recorded temperature at the slab sensor since this item was
last cleared.To clear this item, press and hold the
▲ and ▼
buttons.
The lowest recorded temperature at the slab sensor since this item was last
cleared.To clear this item, press and hold the
▲ and ▼
buttons.
AUTO, 20 to
80%
Default = AUTO
32 to 95°F
(0 to 35°C)
Default = 36°F
(2°C)
Range
-67 to 149°F
(-55 to 65°C)
-67 to 149°F
(-55 to 65°C)
-58 to 167°F
(-50 to 75°C)
-58 to 167°F
(-50 to 75°C)
Item
Item
Ltd
User
665 Schd (Schedule) Menu
The setback override that is in effect for the snow melting system.
None – No override, AWAY – The snowmelting system is shut down
Ltd
User
665 Misc (Miscellaneous) Menu
The units of measure that all of the temperatures are to be displayed in
by the control.
The operating mode for the back lighting on the LCD as well as time
of keypad inactivity until the control automatically returns to the default
display.
The access level that is to be used by the control. DIP Switch =
(Only qualified service people should adjust items in the ADV (Advance)
and INST (Installer) access levels
This User Brochure contains standard information on how to make adjustments to an installed product. More detailed
information can be found in this product’s Installation and Operation Manual (665_D) at www.tekmarControls.com
tekmar Control Systems Ltd., A Watts Water Technologies Company.