Page 1

Vision II WPB
Continuous weighing
QUICK-START GUIDE
The following instructions are given to enable a quick start
of the control box by using the 3 main menus:
• MAIN (button ref. 8)
• INFORMATION (button ref. 9)
• SETTING (button ref. 10)
and for each one their scroll down sub-menus.
For further information, read the user manual
ON
Turn on the power
Ref : 400 363- GB/DIS-00
Page 2

SETTING MENU “SET”
Select the SET menu and
perform in order the
following operations
FORWARD SPEED CALIBRATION
NB : Speed calibration is done over a distance of 100 m
• Mark out a distance of 100 m
•
Position the tractor at the 1st mark
1
0m 100m
2
1. 1.000 m/Pulse
2. 1.000 m/Pulse
3. 2.000 m/Pulse
4. 0.016 m/Pulse
5. NMEA VTG
ESC
M
A
I
N
S
E
T
Select
3
• Select “calibrate over
100 m”
• Press enter at 1st mark
0m 100m
5
• Speed calibration is complete
• Press
ESC
to exit.
• Select
tractor N°1
• Press on
4
• Go forward 100 m
• Press enter at 2nd mark
• Enter again to confi rm
0m 100m
Page 3

PROGRAMMING THE WORKING WIDTH
1 2
• Select
3 4
• Enter
CHOICE OF FERTILISER
1
1
2
3
ABC
DEF
5
6
JKL
MNO
8
9
TUV
WXYZ
PQRS
& -
4
GHI
7
0
Enter the width (in metres)
on the numeric keypad.
Example : 28 metres
• Press to exit
2
• Select the product
(already memorised) with
the arrow keys
• Select
• Press to exit
ESC
PERFORM A TARE (Hopper empty)…
1 2
• Select
to reset
• Select
• Enter
Page 4

… AND CHOOSE THE CALIBRATION MODE
3 4
• Select to
activate the STAT mode
NB : Always start with the
STAT mode
• Press to exit
FILL THE HOPPER
MAIN MENU “MAIN”
Select the main menu MAIN and perform the following
operations in order
Presentation of the MAIN menu
1 Time
2 Speed
3 Rate being spread kg/ha
4 Shows position of electric actuators
connected to rate shutters
5 Rate modulation +10%
6 Rate modulation -10% and return
to initial rate setting after a
modulation of +/- 10%
7 TRIBORD 3D control:
Yield TRIBORD
Enivironment TRIBORD
8 «Left» or «Right» side modulation
selection
9 Rate test
10 Shows if hydraulic shutters are
opened/closed
11 Weight in the hopper (Real)
12 Programmed rate per hectare
13 Alarm
14 Shows chosen correction mode :
dynamic or static
15 Name of fertiliser
PROGRAMMING THE RATE in Kg/Ha
1 2
1
2
& -
4
GHI
7
PQRS
3
ABC
DEF
5
6
JKL
MNO
8
9
TUV
WXYZ
0
Enter the required rate
with the numeric keypad.
Example : 150 Kg/Ha
• Enter
• The rate is displayed
Page 5

FERTILISER CALIBRATION IN STATic MODE
STATIC MODE
This has already been pre-selected from the SET menu
(settings)
1 2
•
This message appears
•
•
Press
•
« TEST » fl ashes
3 4
Wait until the message
disappears before
starting to spread
This message appears
•
After 200 kg
has been spread,
« STOP » fl ashes
•
Stop spreading when
possible and when the
tractor is on a fl at area
(shutters closed)
•
Press « STOP »
• Repeat the fertiliser calibration in the STATic mode a second
time before changing to DYNamic mode
•
•
The calibration (T-factor)
has been saved
FERTILISER CALIBRATION IN DYNamic MODE...
• Return to the SET menu (settings) and activate the
DYNamic calibration mode
S
+
E
T
• Return to the MAIN menu
+
+
ESC
Page 6

.…
FERTILISER CALIBRATION IN DYNamic MODE
1
IMPORTANT
• Activate « STOP » during
transport on roads or
refi lling
• Do not use the DYNamic
• Select the AUTO mode
• During spreading,
there is automatic rate
correction.
mode when refi lling from
a front tank on the move
• The DYNamic mode moves
to « STOP » when the
hopper contents < 200 kg
INFORMATION MENU “INFO”
Select the INFO menu to check spreading performance.
Presentation of the INFO menu