Sulky VISION 2 WPB User Manual

Page 1
Vision II WPB
QUICK-START GUIDE
The following instructions are given to enable a quick start of the control box by using the 3 main menus:
MAIN (button ref. 8)
INFORMATION (button ref. 9)
SETTING (button ref. 10)
and for each one their scroll down sub-menus.
For further information, read the user manual
ON
Turn on the power
Ref : 400 363- GB/DIS-00
Page 2
SETTING MENU “SET”
Select the SET menu and perform in order the following operations
FORWARD SPEED CALIBRATION
NB : Speed calibration is done over a distance of 100 m
• Mark out a distance of 100 m
Position the tractor at the 1st mark
1
0m 100m
2
1. 1.000 m/Pulse
2. 1.000 m/Pulse
3. 2.000 m/Pulse
4. 0.016 m/Pulse
5. NMEA VTG
ESC
M A
I
N
S
E T
Select
3
• Select “calibrate over 100 m”
• Press enter at 1st mark
0m 100m
5
• Speed calibration is complete
• Press
ESC
to exit.
• Select tractor N°1
• Press on
4
• Go forward 100 m
• Press enter at 2nd mark
• Enter again to confi rm
0m 100m
Page 3
PROGRAMMING THE WORKING WIDTH
& -
ABC
DEF
GHI
JKL
MNO
PQRS
TUV
WXYZ
1 2
• Select
3 4
• Enter
CHOICE OF FERTILISER
1
1
2
3
ABC
DEF
5
6
JKL
MNO
8
9
TUV
WXYZ
PQRS
& -
4
GHI
7
0
Enter the width (in metres) on the numeric keypad.
Example : 28 metres
• Press to exit
2
• Select the product (already memorised) with the arrow keys
• Select
• Press to exit
ESC
PERFORM A TARE (Hopper empty)…
1 2
• Select
to reset
• Select
• Enter
Page 4
& -
ABC
DEF
GHI
JKL
MNO
PQRS
TUV
WXYZ
… AND CHOOSE THE CALIBRATION MODE
3 4
• Select to
activate the STAT mode
NB : Always start with the
STAT mode
• Press to exit
FILL THE HOPPER
MAIN MENU “MAIN”
Select the main menu MAIN and perform the following operations in order
Presentation of the MAIN menu
1 Time 2 Speed 3 Rate being spread kg/ha 4 Shows position of electric actuators
connected to rate shutters
5 Rate modulation +10% 6 Rate modulation -10% and return
to initial rate setting after a modulation of +/- 10%
7 TRIBORD 3D control:
Yield TRIBORD
Enivironment TRIBORD
8 «Left» or «Right» side modulation
selection
9 Rate test 10 Shows if hydraulic shutters are
opened/closed
11 Weight in the hopper (Real) 12 Programmed rate per hectare 13 Alarm 14 Shows chosen correction mode :
dynamic or static
15 Name of fertiliser
PROGRAMMING THE RATE in Kg/Ha
1 2
1
2
& -
4
GHI
7
PQRS
3
ABC
DEF
5
6
JKL
MNO
8
9
TUV
WXYZ
0
Enter the required rate with the numeric keypad.
Example : 150 Kg/Ha
• Enter
• The rate is displayed
Page 5
FERTILISER CALIBRATION IN STATic MODE
STATIC MODE
This has already been pre-selected from the SET menu (settings)
1 2
This message appears
Press
« TEST » fl ashes
3 4
Wait until the message disappears before starting to spread
This message appears
After 200 kg has been spread, « STOP » fl ashes
Stop spreading when possible and when the tractor is on a fl at area (shutters closed)
Press « STOP »
• Repeat the fertiliser calibration in the STATic mode a second time before changing to DYNamic mode
The calibration (T-factor) has been saved
FERTILISER CALIBRATION IN DYNamic MODE...
• Return to the SET menu (settings) and activate the DYNamic calibration mode
S
+
E T
• Return to the MAIN menu
+
+
ESC
Page 6
.…
FERTILISER CALIBRATION IN DYNamic MODE
1
IMPORTANT
• Activate « STOP » during transport on roads or refi lling
• Do not use the DYNamic
• Select the AUTO mode
• During spreading, there is automatic rate correction.
mode when refi lling from a front tank on the move
• The DYNamic mode moves to « STOP » when the hopper contents < 200 kg
INFORMATION MENU “INFO”
Select the INFO menu to check spreading performance.
Presentation of the INFO menu
Loading...