Silvercrest SPWD 180 A1 User Manual [en, pl, cs, de]

English ................................................................................ 2
Polski ................................................................................ 13
Magyar ............................................................................. 24
Česky ................................................................................ 47
Slovenčina ........................................................................ 58
Deutsch ............................................................................. 69
V 1.22
SilverCrest SPWD 180 A1
Table of contents
Introduction ........................................................................................................ 3
Intended use ...................................................................................................... 3
Supplied items .................................................................................................... 3
Overview ........................................................................................................... 3
LCD display ....................................................................................................................................... 4
Technical data .................................................................................................... 5
Safety instructions .............................................................................................. 5
Copyright ........................................................................................................... 7
Prior to use ......................................................................................................... 7
Inserting / removing the battery ...................................................................................................... 7
Entering or changing personal data ................................................................................................ 8
First use .............................................................................................................. 8
Switching on the scales / measuring weight .................................................................................. 8
Switching on scales / measuring weight, required calorie intake and body fat, water, bone
and muscle percentages .................................................................................................................. 9
Auto Power Off ................................................................................................................................. 9
Troubleshooting ............................................................................................... 10
Nothing is indicated on the LCD display ..................................................................................... 10
"Lo" is indicated on the LCD display and the scales switch off ................................................... 10
"USEL" is indicated on the LCD display and the scales switch off .............................................. 10
"Err" is indicated on the LCD display ............................................................................................ 10
"Err2" is indicated on the LCD display ......................................................................................... 10
Cleaning / maintenance ................................................................................... 10
Environmental and disposal information .......................................................... 11
Disposal of batteries ...................................................................................................................... 11
Conformity information .................................................................................... 11
Warranty and servicing advice ........................................................................ 12
2 - English
SilverCrest SPWD 180 A1
Introduction
Thank you for purchasing a SilverCrest product. The SilverCrest diagnostic scales SPWD 180 A1, hereinafter referred to as diagnostic scales, are used for the convenient and precise determination of your body weight. Furthermore, the diagnostic scales can be used to measure body fat, water, muscle and bone percentages. You can also determine your required daily calorie intake. The diagnostic scales are impressive with their sleek design and ease of use.
Intended use
These diagnostic scales are used to determine a person's weight. Furthermore, it is possible to measure body fat, water, muscle and bone percentages and to determine your required daily calorie intake. These diagnostic scales should not be used outdoors or in tropical climates. These diagnostic scales are not designed for commercial use or operation in a company. Use the diagnostic scales only for private purposes in living areas as any other use is not as intended. These diagnostic scales meet all relevant norms and standards in conjunction with CE conformity. In the event of any modification to the diagnostic scales that was not approved by the manufacturer, compliance with these standards is no longer guaranteed. The manufacturer does not accept any liability for any resulting damage or faults in such cases. Only use accessories specified by the manufacturer.
Please observe the regulations and laws in the country of use.
Supplied items
SilverCrest diagnostic scales SPWD 180 A1 1 lithium battery CR2032 These operating instructions
Overview
These operating instructions have a fold-out cover. The diagnostic scales are illustrated with numbers on the inside cover. The numbers indicate the following:
1 LCD display 2 ▲ button 3 SET button 4 ▼ button 5 Tread 6 Electrodes 7 Button for setting the unit of weight 8 Battery compartment
English - 3
SilverCrest SPWD 180 A1
LCD display
9 Bone percentage 10 Body height in cm 11 Percentage (of body fat, water, muscle) 12 Body height in feet:inches 13 Unit of weight in kilograms 14
st:lb Unit of weight in stones:pounds lb Unit of weight in pounds
15 Body fat percentage 16 Water percentage 17 Recommended calorie intake per day 18 Obese 19 Overweight 20 Normal weight 21 Underweight 22 User profile memory 23 Male 24 Female 25 Muscle percentage 26 Age
4 - English
SilverCrest SPWD 180 A1
Technical data
Operating voltage: 3V Battery: 1 x 3V lithium battery CR2032 Units of weight: kg / st / lb (adjustable) Weighing range: 5kg to max. 180kg / 396lb / 28st Graduation: 0.1kg / 0.2lb Measuring tolerance: +/- (1% +0.1 kg/ 0.2lb) for 30kg to 180kg Auto Power Off function: approx. 15 seconds User profile memories: 10 Gender: male / female Age range: 10-80 years of age Levels of activity: 5 (none, little, normal, moderate, intense) Body height range: 100 to 220cm Dimensions (W x D x H): 300 x 300 x 21mm Weight: approx. 1600g including battery Operating temperature: +10°C to +40°C
The technical data and design may be changed without notification.
Safety instructions
Before using the diagnostic scales for the first time, please read the following instructions and pay attention to all warnings, even if you are familiar with handling electronic devices. Store these operating instructions in a safe place for future reference. If you sell the diagnostic scales or pass them on, always include these instructions.
WARNING! This symbol indicates important information for safe operation of the diagnostic scales and the safety of the user.
This symbol indicates that one must not step on the diagnostic scales with wet or
damp feet. The same applies if the tread is wet or damp. You could slip and injure yourself.
This symbol indicates other important information on the topic.
English - 5
SilverCrest SPWD 180 A1
These diagnostic scales can be used by children aged 8 and older and by persons with reduced physical, sensory or mental abilities or lack of experience and knowledge if they are supervised or have been instructed on the safe use of the diagnostic scales and understand the resulting risks. Children must not play with the diagnostic scales. Cleaning and user maintenance must not be carried out by children without supervision. Always keep plastic packaging away from children. It poses a suffocation risk.
Do not use the diagnostic scales under any circumstances if you wear a pacemaker. Never use the diagnostic scales in the vicinity of anyone who wears a pacemaker or other medical devices.
The diagnostic scales are not suitable for pregnant women. Do not step on the diagnostic scales with wet or damp feet or when the tread is damp. You
could slip and injure yourself.
Do not overload the diagnostic scales with more than 180kg. Otherwise, the diagnostic scales could be damaged and there is a risk of injury.
Do not jump on the tread of the diagnostic scales. It could be damaged otherwise and there is a risk of injury.
If smoke is produced, or there are any unusual sounds or smells, remove the battery immediately from the diagnostic scales. In such cases, the diagnostic scales should not be used until they have been inspected by authorised service personnel. Never inhale smoke from a potential device fire. If you have inhaled smoke, however, consult a doctor. The inhalation of smoke can be harmful.
The diagnostic scales must not become damaged in order to prevent hazards.
Ensure that no fire sources (e.g. burning candles) are placed on or near the diagnostic scales. It poses a fire hazard!
The diagnostic scales must never be exposed to any direct heat sources (for example, heaters) or direct sunlight or artificial light. Also avoid contact with dripping water and splashes and corrosive liquids. Do not use the diagnostic scales near water. In particular, the diagnostic scales should never be submerged in liquid (do not place any items filled with liquid, e.g. vases or drinks, on the diagnostic scales). Also ensure that the diagnostic scales are never subjected to excessive shocks and vibrations. Furthermore, no foreign objects may penetrate the device. Otherwise, the diagnostic scales could be damaged.
If the battery has leaked, remove it to prevent damage to the diagnostic scales. You can remove leaked battery fluid with a dry, absorbent cloth. Wear suitable gloves for this purpose! Contact with the skin must be avoided. In the event of skin or eye contact with chemicals, they must be immediately rinsed with generous amounts of water and a doctor must be consulted.
6 - English
SilverCrest SPWD 180 A1
Copyright
All information contained in these instructions is subject to copyright and is provided for information purposes only. It is only permitted to copy or duplicate data and information with the express and written consent of the author. This also includes commercial use of the content and data. The text and illustrations are based on the state of the art at the time of printing. Subject to change.
Prior to use
Inserting / removing the battery
To insert the lithium battery CR2032, open the cover of the battery compartment at the rear of the diagnostic scales by slipping your finger into the slot on the side of the battery compartment (8). Now remove the cover of the battery compartment (8) and insert the enclosed lithium battery CR2032. Pay attention to the polarity when inserting the battery. This is indicated in the battery compartment (8), and the + symbol on the lithium battery CR2032 must be visible, as shown in the illustration.
To remove the battery, push it down a bit (see the direction of the arrow in the illustration). You can then remove the battery from the holder.
Then replace the cover on the battery compartment (8). The diagnostic scales are now ready to use.
English - 7
SilverCrest SPWD 180 A1
Entering or changing personal data
You must enter your personal data when you first measure your body weight, required calorie intake and body fat, water, bone and muscle percentages. To do so, proceed as follows:
Press the SET button (3) to switch on the scales. Press the SET button (3) again to enter or change your personal data. The user profile memory (22) then flashes on the LCD display (1). Use the ▲ button (2) or ▼
button (4) to select the desired user profile memory (22) [P0 to P9]. Confirm your selection using the SET button (3).
You can then successively enter gender [male (23)/female (24)], age (26), height and level
of activity via the ▲ button (2) and ▼ button (4). Confirm each entry using the SET button (3).
You can use the level of activity to specify your sporting activity. 5 levels of activity are available: AC-1 = none, AC-2 = little, AC-3 = normal, AC-4 = moderate and AC-5 = intense.
First use
Solid ground is required to measure weight correctly. Thus always place the diagnostic scales on a solid, horizontal floor covering and never on carpet. This can distort the measurement result.
To obtain comparable measurement results, you should always weigh yourself if possible at the same time of day (preferably in the morning). Always weigh yourself if possible under the same conditions: on an empty stomach, after having gone to the toilet and naked.
Please note that values for the stone unit of weight are not represented as decimal values. The display is divided into two segments by a colon. Only whole numbers are displayed in the "st" unit of weight to the left of the colon. The remaining weight is displayed in the "lb" unit of weight to the right of the colon.
Example: "6:6 ½ st:lb" is shown on the display. This corresponds to 6st and
6.5lb.
Switching on the scales / measuring weight
Due to the step on power function, the diagnostic scales are switched on automatically when you step on the tread (5) and they start to measure your weight immediately.
8 - English
SilverCrest SPWD 180 A1
In their original state, the diagnostic scales are set to the "kg" (13) unit of weight. To change the unit of weight, press the "Button for setting the unit of weight" (7) when the scales are switched on. The selected unit of weight is then indicated on the LCD display (1).
Stand on the tread (5) of the diagnostic scales so that your weight is evenly distributed. Remain as still as possible during the weighing process as the measurement result may be distorted otherwise. The measurement result is indicated on the LCD display (1) during the weighing process. The measurement is complete when the display flashes twice.
Switching on scales / measuring weight, required calorie intake and body fat, water, bone and muscle percentages
You must first enter your personal data before performing these measurements. Please pay particular attention to the section "Entering or changing personal data". Proceed as follows to perform the measurement:
Press the SET button (3) to switch on the scales. Press the ▲ button (2) or ▼ button (4) to select the desired user profile memory (22). Stand barefoot on the tread (5) and make sure that you are standing on both electrodes (6). The measurement then starts. Remain standing on both electrodes (6) until the measurement is
complete. Remain as still as possible during the weighing process as the measurement result may be distorted otherwise.
After measuring successfully, the following values are displayed three times in succession:
o Body weight o Body fat percentage (15) and obese (18), overweight (19), normal weight (20) or
underweight (21)
o Water percentage (16) o Muscle percentage (25) o Bone percentage (9) o Recommended calorie intake per day (17)
Auto Power Off
The diagnostic scales have an automatic switch-off function (Auto Power Off function). After displaying the measurement result, the diagnostic scales switch off automatically.
English - 9
SilverCrest SPWD 180 A1
Troubleshooting
Nothing is indicated on the LCD display
The lithium battery CR2032 is empty. Replace the lithium battery CR2032 with another of the
same type. In this case, please observe the instructions for inserting the battery on page 7.
The lithium battery CR2032 is inserted incorrectly. In this case, please observe the instructions
for inserting the battery on page 7.
"Lo" is indicated on the LCD display and the scales switch off
The lithium battery CR2032 is almost empty. Replace the lithium battery CR2032 with
another of the same type. In this case, please observe the instructions for inserting the battery on page 7.
"USEL" is indicated on the LCD display and the scales switch off
An error has occurred and the diagnostic scales cannot perform the measurement. In this
case, step off the tread (5) of the diagnostic scales and start the measurement again.
"Err" is indicated on the LCD display
Your weight exceeds the maximum load capacity of 180kg / 396lb / 28st. You should step
off the tread (5) of the diagnostic scales immediately to avoid damaging the scales.
"Err2" is indicated on the LCD display
An incorrect measurement has occurred. In this case, step off the tread (5) of the diagnostic
scales and start the measurement again. Make sure that you are standing on both electrodes (6).
Cleaning / maintenance
It is necessary to service the diagnostic scales if they have been damaged in any way, for example, if the housing is damaged, if liquid or objects have penetrated the scales or if they have been exposed to rain or moisture. Servicing is also required if the scales are not working properly or have been dropped. If smoke is produced, or there are any unusual sounds or smells, remove the battery immediately from the diagnostic scales. In such cases, the diagnostic scales should not be used until they have been inspected by authorised service personnel. Only have qualified personnel
10 - English
SilverCrest SPWD 180 A1
carry out the maintenance work on the device. Never open the housing of the diagnostic scales. Only use a clean, dry cloth for cleaning and never use any corrosive liquids.
Environmental and disposal information
When the crossed out wheelie bin symbol appears on a product, this indicates that the product is subject to the European Directive 2012/19/EU. All old electrical and electronic devices must be separated from normal household waste and disposed of at designated state facilities. The correct disposal of old devices in this manner will prevent environmental pollution and human health hazards. The battery must be removed from the device before it is scrapped.
For further information about proper disposal, contact your local authorities, waste disposal office or the shop where you bought the device.
Dispose of the packaging in an environmentally compatible manner. Cardboard can be put out for municipal paper collections or brought to public collection points for recycling. Films and plastic used for packaging the device are collected by your local disposal services and disposed of in an environmentally compatible manner.
Disposal of batteries
Remember to protect the environment. Used batteries should not be disposed of in household waste. They must be taken to a collection point for old batteries. Please note that only discharged batteries may be deposited in collection bins for portable batteries. Care must be taken to ensure that batteries that are not fully discharged do not short circuit.
Conformity information
This device meets the basic requirements and other relevant regulations of the EMC Directive 2004/108/EC as well as the RoHS Directive 2011/65/EU. The Declaration of Conformity can be found at the end of this manual.
English - 11
SilverCrest SPWD 180 A1
Warranty and servicing advice
Warranty of TARGA GmbH
This device is sold with three years warranty from the date of purchase. Please keep the original receipt in a safe place as proof of purchase. Before using your product for the first time, please read the enclosed documentation. Should any problems arise which cannot be solved in this way, please call our hotline. Please have the article number and, if available, the serial number to hand for all enquiries. If it is not possible to solve the problem on the phone, our hotline support staff will initiate further servicing procedures depending on the fault. Within the warranty period the product will be repaired or replaced free of charge as we deem appropriate. No new warranty period commences if the product is repaired or replaced. Consumables such as batteries, rechargeable batteries and lamps are not covered by the warranty.
Your statutory rights towards the seller are not affected or restricted by this warranty.
Service
E-Mail: service.GB@targa-online.com
E-Mail: service.IE@targa-online.com
E-Mail: service.MT@targa-online.com
E-Mail: service.CY@targa-online.com
IAN: 41592
Phone: 0207 – 36 50 744
Phone: 01 – 242 15 83
Phone: 800 – 62 175
Phone: 800 – 92 496
Manufacturer
TARGA GmbH
Coesterweg 45 59494 SOEST GERMANY
12 - English
SilverCrest SPWD 180 A1
Spis treści
Wstęp ................................................................................................................14
Użytkowanie zgodne z przeznaczeniem ...........................................................14
Zakres dostawy ................................................................................................14
Przegląd ...........................................................................................................14
Wyświetlacz LCD ........................................................................................................................... 15
Dane techniczne ................................................................................................16
Wskazówki bezpieczeństwa .............................................................................16
Prawa autorskie ...............................................................................................18
Przed uruchomieniem .......................................................................................18
Wkładanie / wymiana baterii ...................................................................................................... 18
Wprowadzanie lub zmiana danych osobowych ........................................................................ 19
Uruchomienie ....................................................................................................19
Włączanie wagi / pomiar masy ciała ......................................................................................... 19
Włączanie wagi / pomiar masy ciała / zapotrzebowania na kalorie, udziału tłuszczu,
wody, kości i mięśni ....................................................................................................................... 20
Automatyczne wyłączenie ............................................................................................................ 20
Rozwiązywanie problemów .............................................................................21
Brak wskazań na wyświetlaczu LCD. ........................................................................................... 21
Wskazanie "Lo" na wyświetlaczu i waga wyłącza się. .............................................................. 21
Wskazanie "USEL" na wyświetlaczu i waga wyłącza się. .......................................................... 21
Wskazanie "Err" na wyświetlaczu. ............................................................................................... 21
Wskazanie "Err2" na wyświetlaczu. ............................................................................................. 21
Konserwacja / czyszczenie ...............................................................................21
Wskazówki dotyczące ochrony środowiska i prawidłowego usuwania ..........22
Usuwanie zużytych baterii ............................................................................................................ 22
Deklaracja zgodności ........................................................................................22
Informacje na temat gwarancji i serwisowania ................................................23
Polski - 13
SilverCrest SPWD 180 A1
Wstęp
Dziękujemy za zakup produktu SilverCrest. Waga diagnostyczna SilverCrest SPWD 180 A1, zwana dalej "waga", służy do wygodnego i dokładnego określania masy ciała. Dodatkowo, waga umożliwia pomiar udziału tłuszczu, wody, mięśni i kości w masie ciała. Można też ustalić dzienne zapotrzebowanie na kalorie. Cechuje się ona eleganckim wzornictwem i łatwą obsługą.
Użytkowanie zgodne z przeznaczeniem
Niniejsza waga służy do określania masy ciała osób. Ponadto, waga umożliwia pomiar udziału tłuszczu, wody, mięśni i kości w masie ciała oraz ustalenie dziennego zapotrzebowanie na kalorie. Wagi nie wolno używać poza pomieszczeniami zamkniętymi i w rejonach o klimacie tropikalnym. Waga nie jest przewidziana do stosowania w przedsiębiorstwach ani do zastosowań komercyjnych. Waga jest przeznaczona wyłącznie do użytku prywatnego, a każde inne użytkowanie uznaje się za niezgodne z przeznaczeniem. Waga spełnia wymagania wszystkich odnośnych norm i dyrektyw, związanych ze zgodnością CE. W przypadku nieuzgodnionych z producentem modyfikacji wagi nie można zagwarantować spełnienia wymagań tych norm. Producent nie ponosi żadnej odpowiedzialności za wynikłe z tego szkody lub zakłócenia. Należy stosować tylko akcesoria zalecane przez producenta.
Należy przestrzegać przepisów krajowych lub przepisów kraju użytkowania.
Zakres dostawy
Waga diagnostyczna SilverCrest SPWD 180 A1 1 bateria litowa CR2032 Niniejsza instrukcja obsługi
Przegląd
Niniejsza instrukcja ma odchylaną okładkę. Na wewnętrznej stronie odchylanej okładki jest przedstawiona waga wraz z oznaczeniami liczbowymi. Liczby mają następujące znaczenie:
1 Wyświetlacz LCD 2 Przycisk ▲ 3 Przycisk SET 4 Przycisk ▼ 5 Powierzchnia ważenia 6 Elektrody 7 Przycisk do ustawiania jednostki miary 8 Wnęka baterii
14 - Polski
Wyświetlacz LCD
9 Udział kości 10 Wzrost w cm 11 Udział procentowy (tłuszczu, wody, mięśni) 12 Wzrost w „feet:inch“ 13 Jednostka miary w kg 14
st:lb Jednostka miary w „Stones:Pounds“ lb Jednostka miary w „Pounds“
15 Udział tłuszczu w masie ciała 16 Udział wody w masie ciała 17 Zalecane dzienne zapotrzebowanie na kalorie 18 Otyłość 19 Nadwaga 20 Normalna waga ciała 21 Niedowaga 22 Miejsce w pamięci na profil użytkownika 23 Mężczyzna 24 Kobieta 25 Udział mięśni w masie ciała 26 Wiek
SilverCrest SPWD 180 A1
Polski - 15
SilverCrest SPWD 180 A1
Dane techniczne
Napięcie zasilania: 3 V Bateria: 1 x 3 V bateria litowa CR2032 Jednostki miary: kg / st / lb (przełączane) Zakres ważenia: 5 kg do maks. 180 kg / 396 lb / 28 st Podziałka: 0,1 kg / 0,2 lb Tolerancja pomiaru: +/- (1% +0,1 kg / 0,2 lb) przy 30 kg do 180 kg Automatyczne wyłączenie: po ok. 15 sekundach Liczba miejsc w pamięci na profile
użytkownika: 10 Płeć: mężczyzna / kobieta Zakres wiekowy: 10 - 80 lat Stopnie aktywności: 5 (brak, niewielka, normalna, średnia, intensywna) Zakres wzrostu: 100 – 220 cm Wymiary (S x G x W) 300 x 300 x 21 mm Masa: ok. 1600 g łącznie z baterią Temperatura robocza: +10°C do +40°C
Zastrzegamy możliwość zmian danych technicznych i konstrukcyjnych bez wcześniejszego uprzedzenia.
Wskazówki bezpieczeństwa
Przed pierwszym użyciem wagi prosimy dokładnie zapoznać się z poniższymi instrukcjami. Należy stosować się do wszystkich ostrzeżeń o zagrożeniach, nawet jeśli masz doświadczenie w obsłudze urządzeń elektronicznych. Niniejszą instrukcję obsługi należy starannie przechowywać do wykorzystania w przyszłości. W razie sprzedaży lub przekazania wagi należy koniecznie dołączyć do niej niniejszą instrukcję.
OSTRZEŻENIE! Symbol ten oznacza ważne instrukcje w związku bezpieczną eksploatacją wagi i ochroną użytkownika.
Ten symbol oznacza, że na wagę nie można wchodzić z wilgotnymi lub
mokrymi stopami. Nie wolno także wchodzić na wagę, gdy jej powierzchnia ważenia jest wilgotna lub mokra. Można się wówczas poślizgnąć i istnieje niebezpieczeństwo zranienia.
Ten symbol oznacza dalsze, przydatne informacje na ten temat.
16 - Polski
SilverCrest SPWD 180 A1
Ta waga może być używana przez dzieci od 8. roku życia oraz przez osoby o zmniejszonych zdolnościach fizycznych, sensorycznych lub umysłowych lub też osoby nieposiadające odpowiedniego doświadczenia i/lub wiedzy, wyłącznie pod nadzorem lub po przeszkoleniu w zakresie bezpiecznego używania wagi oraz wynikających z niego zagrożeń. Dzieci nie mogą bawić się wagą. Czyszczenie i konserwacja przez użytkownika nie mogą być wykonywane przez dzieci bez nadzoru. Folie z opakowań należy także przechowywać poza zasięgiem dzieci. Istnieje niebezpieczeństwo uduszenia.
Osoby posiadające rozrusznik serca bezwzględnie nie mogą korzystać z wagi. W żadnym przypadku nie używać wagi w pobliżu osób, które mają rozrusznik serca lub inne urządzenia medyczne.
Waga nie nadaje się do stosowania przez kobiety w ciąży.
Na powierzchnię ważenia wagi nie można wchodzić z wilgotnymi lub mokrymi stopami ani gdy powierzchnia ważenia jest mokra. Można się wówczas poślizgnąć i istnieje niebezpieczeństwo zranienia.
Nie należy obciążać wagi powyżej 180 kg. W przeciwnym razie może dojść do uszkodzenia wagi oraz istnieje niebezpieczeństwo obrażeń.
Nie należy wskakiwać na powierzchnię ważenia wagi. W przeciwnym razie może dojść do jej uszkodzenia oraz istnieje niebezpieczeństwo obrażeń.
W razie stwierdzenia tworzenia się dymu, zauważenia dziwnych odgłosów lub zapachów natychmiast wyjąć baterię z wagi. W takich przypadkach wagi nie wolno dalej używać, dopóki nie zostanie ona sprawdzona przez specjalistę. W żadnym przypadku nie wolno wdychać dymu z możliwego pożaru urządzenia. O ile mimo to doszło do wdychania dymu, należy udać się do lekarza. Wdychanie dymu może być szkodliwe dla zdrowia.
Waga nie może być uszkodzona, by nie dopuścić do powstania zagrożeń.
Należy dopilnować, by na wadze ani w jej pobliżu nie było żadnych źródeł otwartego ognia (np. palące się świece). Istnieje niebezpieczeństwo pożaru!
Waga nie może być narażona na oddziaływanie bezpośrednich źródeł ciepła (np. grzejników) ani bezpośredniego światła słonecznego ani sztucznego. Należy także unikać kontaktu z wodą rozpryskową i kroplową i agresywnymi cieczami. Nie używaj wagi w pobliżu wody. W szczególności, nigdy nie wolno zanurzać wagi w cieczach (nie stawiaj na niej żadnych przedmiotów napełnionych cieczą, np. wazonów ani napojów). Dopilnuj także, aby waga nie była narażona na nadmierne wstrząsy ani drgania. Nie wolno dopuścić, by do wnętrza wagi dostały się ciała obce. W przeciwnym razie może dojść do uszkodzenia wagi.
W razie wylania się baterii należy wyjąć baterię z wagi, by uniknąć uszkodzenia wagi. Ciecz rozlaną z baterii można usunąć suchą, chłonną ściereczką. Należy przy tym używać odpowiednich rękawic! Należy bezwzględnie unikać kontaktu cieczy ze skórą. W razie
Polski - 17
SilverCrest SPWD 180 A1
kontaktu cieczy ze skórą lub z oczami należy natychmiast przepłukać lub wypłukać dużą ilością wody i udać się do lekarza.
Prawa autorskie
Cała zawartość tej instrukcji obsługi jest chroniona prawem autorskim i jest udostępniana czytelnikowi wyłącznie jako źródło informacji. Jakiekolwiek kopiowanie lub powielanie danych i informacji jest zabronione bez wyraźnej i pisemnej zgody autora. Dotyczy to również komercyjnego wykorzystania treści i danych. Tekst i ilustracje są zgodne ze stanem technicznym w chwili druku. Zmiany zastrzeżone.
Przed uruchomieniem
Wkładanie / wymiana baterii
Aby włożyć baterię litową CR2032, otwórz pokrywę wnęki baterii po dolnej stronie wagi, sięgając palcem do wgłębienia z boku wnęki baterii (8). Podnieś teraz pokrywę z wnęki baterii (8) i włóż dołączoną baterię litową CR2032. Zwróć przy tym uwagę na poprawną polaryzację. Jest ona zaznaczona we wnęce baterii (8); symbol + na baterii litowej CR2032 musi być widoczny, jak przedstawiono to na rysunku obok.
Aby wyjąć baterię, przesuń ją nieco w dół (patrz kierunek strzałki na rysunku). Potem można wyjąć baterię z uchwytu.
Na koniec ponownie włóż pokrywę wnęki baterii na wnękę baterii (8). Waga jest gotowa do użytku.
18 - Polski
SilverCrest SPWD 180 A1
Wprowadzanie lub zmiana danych osobowych
Przed pierwszym pomiarem masy ciała, zapotrzebowania na kalorie oraz udziału tłuszczu, wody, kości i mięśni w masie ciała należy wprowadzić dane osobowe. Należy w tym celu wykonać następujące czynności:
Naciśnij przycisk SET (3), aby włączyć wagę. Ponownie naciśnij przycisk SET (3), by wprowadzić lub zmienić dane osobowe. Na wyświetlaczu LCD (1) miga teraz miejsce w pamięci na profil użytkownika (22). Za
pomocą przycisków ▲ (2) i ▼ (4) wybierz żądane miejsce w pamięci na profil użytkownika (22) [P0 do P9]. Zatwierdź wybór przyciskiem SET (3).
Można kolejno wprowadzać płeć [mężczyzna (23) / kobieta (24)], wiek (26), wzrost i
stopień aktywności za pomocą przycisków ▲ (2) i ▼ (4). Zatwierdź każdy wybór przyciskiem SET (3).
Za pomocą stopnia aktywności można określić swoją aktywność sportową. Do dyspozycji jest 5 stopni aktywności: AC-1 = brak, AC-2 = niewielka, AC-3 = normalna, AC-4 = średnia i AC-5 = intensywna.
Uruchomienie
Warunkiem poprawnego pomiaru masy ciała jest stabilne podłoże. Dlatego wagę należy zawsze ustawiać na stabilnym i równym podłożu, zaś nigdy np. na dywanie. Mogłoby to spowodować zafałszowanie wyniku pomiaru.
Dla uzyskania porównywalnych wyników pomiarów, najlepiej jest ważyć się zawsze o tej samej porze dnia (najlepiej rano). Należy ważyć się możliwie zawsze w tych samych warunkach: na czczo, po wizycie w toalecie i bez ubrania.
Należy pamiętać, że w przypadku jednostki miary Stone wartość nie jest przedstawiana jako wartość dziesiętna. Wskazanie jest podzielone dwukropkiem na dwa segmenty. Po lewej od dwukropka przedstawiane są wyłącznie wielkości całkowite w jednostce miary "st". Pozostała część masy jest przedstawiana po prawej stronie dwukropka w jednostce miary "lb".
Przykład: wskazanie na wyświetlaczu „6:6 ½ st:lb“. Odpowiada to 6 st i 6,5 lb.
Włączanie wagi / pomiar masy ciała
Funkcja Step On Power włącza automatycznie wagę z chwilą wejścia na powierzchnię ważenia (5) i rozpoczyna natychmiast pomiar masy ciała.
Polski - 19
SilverCrest SPWD 180 A1
W chwili dostawy waga jest ustawiona fabrycznie na pomiar w jednostce miary "kg" (13). Aby zmienić jednostkę miary, przy włączonej wadze naciśnij przycisk do ustawiania jednostki miary (7). Wybrana jednostka miary będzie każdorazowo widoczna na wyświetlaczu LCD (1).
Stań na powierzchni ważenia (5) wagi w taki sposób, by ciężar ciała był równomiernie rozłożony. W trakcie ważenia nie należy się w miarę możliwości poruszać, by nie zafałszować wyniku pomiaru. Podczas ważenia, wynik pomiaru jest wyświetlany na wyświetlaczu LCD (1). Pomiar jest zakończony dopiero wtedy, gdy wyświetlacz mignie dwa razy.
Włączanie wagi / pomiar masy ciała / zapotrzebowania na kalorie, udziału tłuszczu, wody, kości i mięśni
Przed tymi pomiarami należy najpierw wprowadzić swoje dane osobowe. Zapoznaj się w tym celu z rozdziałem "Wprowadzanie lub zmiana danych osobowych". Aby wykonać pomiar, postępuj w następujący sposób:
Naciśnij przycisk SET (3), aby włączyć wagę. Naciskaj przyciski ▲ (2) i ▼ (4), by wybrać żądane miejsce w pamięci na profil użytkownika
(22).
Stań boso na powierzchni ważenia (5) i dopilnuj, by stać na obu elektrodach (6). Teraz rozpoczyna się pomiar. Do czasu zakończenia pomiaru pozostań stojąc na obu
elektrodach (6). W trakcie ważenia nie należy się w miarę możliwości poruszać, by nie zafałszować wyniku pomiaru.
Po zakończeniu pomiaru zostaną wyświetlone trzy razy po kolei następujące wartości:
o Masa ciała o Udział tłuszczu (15) i otyłość (18), nadwaga (19), normalna waga ciała (20) lub
niedowaga (21).
o Udział wody (16) o Udział mięśni (25) o Udział kości (9) o Zalecane dzienne zapotrzebowanie na kalorie (17)
Automatyczne wyłączenie
Waga ma funkcję automatycznego wyłączenia (Auto Power Off). Po wyświetleniu wyniku pomiarów waga wyłącza się automatycznie.
20 - Polski
SilverCrest SPWD 180 A1
Rozwiązywanie problemów
Brak wskazań na wyświetlaczu LCD.
Bateria litowa CR2032 jest rozładowana. Wymień baterię litową CR2032 na nową. Należy
przy tym przestrzegać wskazówek na temat wkładania baterii na stronie 18.
Bateria litowa CR2032 została włożona niewłaściwie. Należy przy tym przestrzegać
wskazówek na temat wkładania baterii na stronie 18.
Wskazanie "Lo" na wyświetlaczu i waga wyłącza się.
Bateria litowa CR2032 jest niemal rozładowana. Wymień baterię litową CR2032 na nową.
Należy przy tym przestrzegać wskazówek na temat wkładania baterii na stronie 18.
Wskazanie "USEL" na wyświetlaczu i waga wyłącza się.
Wystąpił błąd i waga nie może wykonać pomiaru. W takim przypadku zejdź z powierzchni
ważenia (5) wagi i wejdź na nią ponownie.
Wskazanie "Err" na wyświetlaczu.
Masa przekracza maksymalną nośność wagi 180 kg / 396 lb / 28 st. Należy natychmiast
opuścić powierzchnię ważenia (5), by zapobiec uszkodzeniu wagi.
Wskazanie "Err2" na wyświetlaczu.
Wystąpił błąd pomiaru. W takim przypadku zejdź z powierzchni ważenia (5) wagi i wejdź
na nią ponownie. Dopilnuj, by stać na obu elektrodach (6).
Konserwacja / czyszczenie
Prace konserwacyjne są konieczne, gdy waga została uszkodzona, np. uszkodzona jest obudowa urządzenia lub do środka obudowy dostała się woda lub ciała obce albo gdy waga była narażona na działanie deszczu lub wody. Prace konserwacyjne są także konieczne, gdy waga nie działa prawidłowo lub gdy upadła. W razie stwierdzenia tworzenia się dymu, zauważenia dziwnych odgłosów lub zapachów natychmiast wyjąć baterię z wagi. W takich przypadkach wagi nie wolno dalej używać, dopóki nie zostanie ona sprawdzona przez specjalistę. Wszystkie naprawy należy zlecać tylko wykwalifikowanym specjalistom. Nigdy nie należy otwierać obudowy
Polski - 21
SilverCrest SPWD 180 A1
wagi. Do czyszczenia należy używać wyłącznie czystej, suchej szmatki. Nigdy nie stosować agresywnych cieczy.
Wskazówki dotyczące ochrony środowiska i prawidłowego usuwania
Gdy na produkcie jest umieszczony ten symbol przekreślonego pojemnika na odpady, produkt ten podlega europejskiej dyrektywie 2012/19/EU. Wszystkie urządzenia elektryczne i elektroniczne muszą być usuwane oddzielnie od odpadów domowych i oddawane do specjalnych punków zbiórki. Prawidłowo usuwając zużyte urządzenie zapobiegasz zanieczyszczeniu środowiska i zagrożeniom dla zdrowia. Przed oddaniem urządzenia do utylizacji należy wyjąć z niego baterię.
Więcej informacji na temat usuwania zużytych urządzeń otrzymasz u lokalnych władz, w firmie zajmującej się wywozem odpadów lub u sprzedawcy produktu.
Także opakowanie należy usunąć w sposób przyjazny dla środowiska. Karton można oddać do ponownego przetworzenia w punkcie zbiórki makulatury lub w publicznym punkcie zbiórki. Folie i tworzywa sztuczne z dostawy są zbierane przez lokalne przedsiębiorstwo utylizacji odpadów, po czym są usuwane w sposób przyjazny dla środowiska.
Usuwanie zużytych baterii
Pomyśl o ochronie środowiska. Zużytych baterii nie wolno wyrzucać razem z odpadami domowymi. Należy je oddać w punkcie zbiórki zużytych akumulatorów. Należy pamiętać, że baterie wolno umieszczać w pojemnikach na zużyte baterie tylko w stanie rozładowanym, zaś w przypadku baterii niecałkowicie rozładowanych należy zastosować środki zapobiegające zwarciu.
Deklaracja zgodności
To urządzenie jest zgodne z podstawowymi wymaganiami i innymi ważnymi przepisami dyrektywy w sprawie zgodności elektromagnetycznej 2004/108/EC oraz dyrektywy RoHS 2011/65/EU. Przynależną deklarację zgodności można znaleźć na końcu tej instrukcji obsługi.
22 - Polski
SilverCrest SPWD 180 A1
Informacje na temat gwarancji i serwisowania
Gwarancja firmy TARGA GmbH
Niniejszy produkt jest objęty trzyletnią gwarancją od daty zakupu. Należy zachować oryginalny kwit kasowy jako dowód zakupu. Przed uruchomieniem produktu prosimy dokładnie zapoznać się z załączoną dokumentacją. W razie wystąpienia problemu, którego nie można rozwiązać w ten sposób, prosimy skontaktować się z naszą infolinią pomocy technicznej. Przy każdym kontakcie z infolinią pomocy technicznej należy mieć pod ręką numer artykułu lub numer seryjny, jeśli jest dostępny. W przypadku, gdy rozwiązanie problemu przez telefon nie będzie możliwe, w zależności od przyczyny usterki nasza infolinia pomocy technicznej zorganizuje inną formę serwisowania. W razie stwierdzenia wad materiałowych lub produkcyjnych produktu, zostanie on bezpłatnie naprawiony lub wymieniony na nowy, wedle naszego swobodnego uznania. Naprawa lub wymiana produktu nie powoduje rozpoczęcia nowego okresu gwarancyjnego. Gwarancja nie obejmuje części zużywających się, jak baterie, akumulatory czy elementy oświetlenia.
Gwarancja ta w niczym nie ogranicza ustawowych praw nabywcy w stosunku do sprzedawcy, które pozostają nienaruszone.
Serwis
E-Mail: service.PL@targa-online.com
IAN: 41592
Telefon: 00800 – 4411481
Producent
TARGA GmbH
Coesterweg 45 59494 SOEST GERMANY
Polski - 23
Loading...
+ 57 hidden pages