Schneider Electric TAC Xenta® 280, TAC Xenta® 300, TAC Xenta® 3000 Instruction Manual

148 – 2.0 (5.83 – 0.08)
4.0
(0.16)
48 – 0,5
(1.89–0.02)
16.1
(0.63)
180 (7.09)
77.4 (3.05)
45
(1.77)
110
(4.33)
180 + 0.4 (7.09 + 0.02) to the next TAC Xenta 280/300/3000 174 + 0.4 (6.85 + 0.02) to the next TAC Xenta 400/500/900
mm (in.):
20
17
18
16
19
15
12
13
11
14
40
37
38
36
39
35
32
33
31
34
10
7
8
6
9
5
2
3
1
4
30
27
28
26
29
25
22
23
24
21
K2 KC1 K1
Y2
G0
Y1
G
M
X2
M
M
X1
M
U4
U3 U2
C2
U1
M
C1
K3
KC2
0~24 V
AC/DC
}
Comm
{
max 230 V AC
Y3
M
max 230 V AC
20
17
18
16
19
15
12
13
11
14
40
37
38
36
39
35
32
33
31
34
10
7
8
6
9
5
2
3
1
4
30
27
28
26
29
25
22
23
24
21
K4 KC2
KC1
K2
K1
K3
M
Y4
Y3 Y2
G0
Y1
G
M
X2
M
M
X1
M
B2
M
M
U4
U3
B1
U2
C2
U1
M
C1
0~24 V
AC/DC
}
Comm
{
20
17
18
16
19
15
12
13
11
14
40
37
38
36
39
35
32
33
31
34
10
7
8
6
9
5
2
3
1
4
30
27
28
26
29
25
22
23
24
21
V2
V6
V5
V1
G0 G
X2
M
M
X1
B3
M
B2
B4
M
M
B1
C2
M
C1
V3
V4
0
~
24 V
AC/DC
}
Comm
{
24 V AC
VC
TAC Xenta® 280/300/3000
Controller Regulator Regler
Installation Instructions
02-00020-01-en
Installationsanvisning
Bedienungsanleitung
Note! The figures only show connections in general. For further details, please refer to the documentation for the specific applications. Do NOT use unmarked terminals. Do not use the product for any other purposes than those indicated in this document.
Observera! Figurerna visar endast generella inkopplingar. För detaljer, se dokumentationen till de speci­fika applikationerna. Använd EJ ospecificerade plintar! Produkten får enbart användas i de syften som detta dokument beskriver.
Anmerkung! Die Abbildungen zeigen lediglich die allgemeine Klemmenbelegung. Weitere Einzelheiten gehen aus der Dokumentation der Anwendung hervor. Bitte nur die in der Abbildung bezeichneten Klem­men belegen! Verwenden Sie das Produkt ausschließlich für den in diesem Dokument beschriebenen Zweck.
TAC Xenta 281 TAC Xenta 282
02-00020-01-en, Mar 2010 1 (2)
TAC Xenta 283
1 2
G G0 U1 M U2 Y1 M Y2 B1 M B2 M U3
G1 G G0
G G0 M X
G G0 MX X1
TAC Xenta 282 or 300/3000
PU
230
VAC
G
G0
N
1 2 1 2
G G0 M S
G G0 M S
R =500 W
Insulated signal ground rail
Cabinet terminals
R
min 1,5 mm2, max 2 m
Cabinet ground rail
20
17
18
16
19
15
12
13
11
14
40
37
38
36
39
35
32
33
31
34
10
7
8
6
9
5
2
3
1
4
30
27
28
26
29
25
22
23
24
21
K2 KC1
KC3
K6
K5
K1
Y2
G0
Y1
G
M
X4
X2
X3
M
M
X1
B3
M
B2
B4
M
M
U4
U3
B1
U2
C2
U1
M
C1
K3
KC2
K4
0
~
24 V AC/DC
}
Comm
{
max 230 V AC
max 230 V AC
20
17
18
16
19
15
12
13
11
14
40
37
38
36
39
35
32
33
31
34
10
7
8
6
9
5
2
3
1
4
30
27
28
26
29
25
22
23
24
21
K4 KC2
KC1
K2
K1
K3
M
Y4
Y3 Y2
G0
Y1
G
M
X4
X2
X3
M
M
X1
B3
M
B2
B4
M
M
U4
U3
B1
U2
C2
U1
M
C1
0 ~
24 V AC/DC
}
Comm
{
TAC Xenta 301 TAC Xenta 302
Note! The figures only show connections in general. For further details, please refer to the documentation for the spe­cific applications. Do NOT use unmarked terminals. Do not use the product for any other purposes than those indicated in this document.
Observera! Figurerna visar endast generella inkopplingar. För detaljer, se dokumentationen till de specifika applikatio­nerna. Använd EJ ospecificerade plintar! Produkten får enbart användas i de syften som detta dokument beskriver.
Anmerkung! Die Abbildungen zeigen lediglich die allgemeine Klemmenbelegung. Weitere Einzelheiten gehen aus der Dokumentation der Anwendung hervor. Bitte nur die in der Abbildung bezeichneten Klemmen belegen! Verwenden Sie das Produkt ausschließlich für den in diesem Dokument beschriebenen Zweck.
2 (2) 02-00020-01-en, Mar 2010
Measuring device 0–10 V
Measuring
Actuator
device (with own trafo)
Trademarks and registered trademarks are the property of their respective owners.
Actuator with differential in­put (FORTA)
Thermistor (2 sensors)
Measuring device, two­wire 4–20 mA
Loading...