Schneider Electric MA41-7300-502 Selection Guide

Selection Guide
Specifications
Input Power and Ratings
Par t Number
Input Signal
Voltage Transformer
Sizing (VA)
Running Watts
Holding Watts
Approx. Timing in Seconds
Approx. Timing in Seconds (Spring Return)
Aux. Sw.
NEMA 4Heater
(Powered)
MA41­7303
Two Position
24 Vac ± 20%, 50/60 Hz, 24
16 VA
1
9.5 4.5 75 <20 at -4 … 122
- - -
°F, <60 at -22 °F
Vdc +20%/-10%
MA41­7303-502
Two Position
24 Vac ± 20% 50/60 Hz, 24
16 VA
1
9.5 4.5 75 <20 at -4 … 122 °F, <60 at -22 °F
2 - -
Vdc +20%/-10%
MA41­7300
Two Position
100 to 240 Vac +10/-20% 50/60 Hz, 100 to 125
21 VA at 100 Vac, 29 VA at 240 Vac
9.5 4.5 75 <20 at -4 … 122 °F, <60 at -22 °F
- - -
Vdc +10/-10%
MA41­7300-502
Two Position
100 to 240 Vac +10/-20% 50/60 Hz, 100 to 125
21 VA at 100 Vac, 29 VA at 240 Vac
9.5 4.5 75 <20 at -4 … 122 °F, <60 at -22 °F
2 - -
Vdc + 10/-10%
MS41­7303
2 to 10
2, 3
Vdc
24 Vac ± 20% 50/60 Hz, 24
16 VA
1
9.5 4.5 150
4
<20 at -4 … 122
- - -
°F, <60 at -22 °F
Vdc +20%/-10%
MS41­7303-502
2 to 10
2, 3
Vdc
24 Vac ± 20% 50/60 Hz, 24
16 VA
1
9.5 4.5 150
4
<20 at -4 … 122
2 - -
°F, <60 at -22 °F
Vdc +20%/-10%
MS41­7303-W02
2 to 10
2, 3
Vdc
24 Vac ± 20% 50/60 Hz, 24
16 VA
1
9.5 4.5 150
4
<20 at -4 … 122
2 Yes -
°F, <60 at -22 °F
Vdc +20%/-10%
MS41­7303-WH2
2 to 10
2, 3
Vdc
24 Vac ± 20% 50/60 Hz, 24
16 VA and 21 w/heater
Vdc +20%/-10%
1
Class 2 power source.
2
2 … 10 Vdc input signal has 100KΩ input impedance. Also compat ble with two-position 24 Vac/Vdc input signals. See MS41-7303-xxx
Alternate Input Signals section in this document. Use optional AM-708 500 ohm resistor for 4 to 20 mA input signal.
3
Also compat ble with oating, pulse width modulating (PWM), and other DC signal inputs with use of the BEL-ZTH US Handheld Interface
Module for Field Programming.
4
Timing eld adjustable from 60 … 150 seconds with use of the BEL-ZTH US Handheld Interface Module for Field Programming.
1
9.5 and
21 w/ heater
4.5 150
4
<20 at -4 … 122
2 Yes Ye s °F, <60 at -40 °F w/heater
Optional Input Signals MS41 models only
Electrical Connections MA41-7303, MA41-7300, MS41­7303
MA41-7303-502, MA41-7300­502, MS41-7303-502
MS41-7303-W02, MS41-7303­WH2
Electrical Outputs Position Feedback, MS41-7303, MS41-7303-502, MS41-7303-W02, MS41-7303­WH2
Auxiliary Switches, MA41-7303­502, MA41-7300-502, MS41-7303-502
Auxiliary Switches, MS41­7303-W02, MS41-7303-WH2
modulating (PWM), Adjustable
Floating, Pulse width
start point, and Span DC signal
inputs with use of the BEL-ZTH
US handheld interface module
for eld programming
3’ appliance cord with 18 Ga.
(0.9 mm) conductors and one
1/2” conduit connector
3’ appliance cord with 18 Ga.
(0.9 mm) conductors and two
1/2” conduit connectors
Removable terminal blocks for
12 (3.4 mm) to 22 (0.4 mm) Ga.
wire inside junction box with six
1/2” knockouts
2 … 10 Vdc, 0.5 mA max,
adjustable with optional BEL-
ZTH US Handheld Interface
Module for Field Programming
2 SPDT 3 A (0.5 A) @ 250 Vac,
UL approved, one xed at 10°,
one adjustable from
10° … 85°
2 SPDT 3 A (0.5 A) @ 250 Vac,
UL approved, one xed at 10°,
one xed at 85°
Mechanical Stroke Angle of rotation 95° max.
(adjustable with integral end
stop 35° … 95°)
Damper Shaft Clamp Size 1/2” … 3/4” round or 1/2” to
11/16” square damper shafts
or to 3/4” … 1.05” round or to
1/2” … 11/16” square damper
shafts with the eld removal of
a clamp and hub insert
Position Indicator Graduated position indicator
showing 0° … 95°; 0° is full
spring return position
Nominal Damper Area Actuator sizing should be done
in accordance with damper
manufacturer’s specications
Direction of Actuator Rotation Clockwise or counterclockwise
determined by the actuator
mounting
Manual Override Actuators provided with 5 mm
hex crank (3/16” Allen)
Input Signal Action Switch MS41-7303, MS41-7303-502, MS41-7303-W02, MS41-7303­WH2
Provides selectable reverse acting/direct acting actuator
rotation, accessible from both
sides
Enclosure Double insulated rugged
aluminum die-cast and plastic
casing
© 2016 Schne ider Ele ctric. All rights rese rved. All trademar ks are owned by Schneider El ectric Indust ries S AS or its a ffil iated companie s. March, 2 016 tc Docume nt Numbe r: F-27870 -1
Dimensions (inch [mm])
NEMA 4 models:
MS41-7303-W02, MS41-7303-WH2
1.06 [27]
4.74 [120.5]
3.15 [80]
0.19 [4.85]
Selection Guide
0.53 [13.5]
0.59 [15]
1.38 [35]
2.76 [70]
0.33 [8.3]
5.43 [138]
4.41 [112]
Note: The above view is with the CCW actuator side facing upward.
7.40 [188]1.97 [50]
13.54 [344]
5.63 [143]
0.20 [5.2]
5.43 [138]
0.52 [13.3]
4.17 [106]
© 2016 Schne ider Ele ctric. All rights rese rved. All trademar ks are owned by Schneider El ectric Indust ries S AS or its a ffil iated companie s. March, 2 016 tc Docume nt Numbe r: F-27870 -1
Selection Guide
Line V
120, 240 Vac
Installation
Inspect the package for damage. If damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage. Return damaged products.
Requirements (not provided with actuator):
13 mm hex socket
Torque wrench
Appropriate screwdriver(s)
Drill and appropriate bits
Sheet metal screws
Appropriate accessories
Job wiring diagrams
Wiring
MA41-7303, MA41-7303-502 Two Position Wiring (24 V)
24 Vac Transformer
1
olts
1 Common
2 + Hot
MA41-7303-xxx
3
On/Off Wir ing
2
Auxiliary Switches
Installation Notes for MA41-7303, MA41-7303-502, MA41-7300, MA41-7300-502, MS41-7303, MS41­7303-502
Use exible metal conduit.
Push the UL listed conduit tting device over the
actuator’s cable to butt against the enclosure.
Screw in conduit connector.
Jacket the actuator’s input wiring with UL listed exible
conduit.
Properly terminate the conduit in a suitable junction box.
Installation Notes for MS41-7303-W02, MS41-7303­WH2
Use 60 °C/75 °C copper (Cu) conductor and wire size range 12 (0.9 mm) to 26 (0.4 mm) Ga., stranded or solid.
If conduit is used, use UL listed and CSA certied
watertight exible metal conduit, strain relief, and conduit tting suitable for outdoor applications, rated
NEMA type 4, 4X, 6 or 6X or watertight.
Provide overload protection and disconnect as required.
1
Actuators may be connected in parallel. See the Mounting Multiple Actuators on a Common Jackshaft section for
2
complete information. Observe power consumption and input impedance.
Actuators may also be powered by 24 Vdc.
3
For end position indication, interlock control, fan startup, etc., MA41-7303-502 incorporates two built-in auxiliary switches: 2x SPDT, 3 A (0.5 A) @ 250 Vac, UL approved.
4
One switch is xed at +10° and one is adjustable from 10°
… 85°.
Meets cULus requirements without the need of an electrical ground connection.
10 to 85°
MA41-7303-502
MA41-7300, MA41-7300-502 Two Position Wiring (Line Voltage)
Wht
Blk
L
© 2016 Schne ider Ele ctric. All rights rese rved. All trademar ks are owned by Schneider El ectric Indust ries S AS or its a ffil iated companie s. March, 2 016 tc Docume nt Numbe r: F-27870 -1
Load
MA41-7300-xxx
10 to 85°
MA41-7300-502
On/Off Wiring
Auxiliar Switches
y
Provide overload protection and disconnect as required.
1
Actuators may be connected in parallel. See the Mounting Multiple Actuators on a Common Jackshaft
2
section for complete information. Observe power consumption and input impedance.
For end position indication, interlock control, fan startup, etc., MA41-7300-502 incorporates two built in auxiliary switches: 2x SPDT, 3 A (0.5 A) @ 250 Vac, UL approved.
3
One switch is xed at +10° and one is adjustable from
10° … 85°.
Meets cULus requirements without the need of an electrical ground connection.