Schneider Electric BG500 Users Manual

Operation Manual
Back-UPS™ Pro
Uninterruptible Power Supply
BG500 120 Vac

Overview

The APC™ by Schneider Electric Back-UPS™ Pro BG500 is a high performance Lithium Ion uninterruptible power supply (UPS). It provides protection for electronic equipment from AC power blackouts, brownouts, sags, and surges, small AC fluctuations and large disturbances. The UPS also provides battery backup power for connected equipment until AC power returns to safe levels or the batteries are fully discharged.

Safety and General Information

Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before installing the UPS.
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
• The battery typically lasts for six to ten years. Environmental factors impact battery life. Elevated ambient temperatures, poor quality AC power, and frequent short duration discharges will shorten battery life.
• Connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords.
• Before installing or replacing the batteries, remove jewelry such as wrist watches and rings. High short circuit current through conductive materials could cause severe burns.

Specifications

For additional specifications, refer to the APC by Schneider Electric Web site at www.apc.com.
Model
VA 500 VA
Maximum Load Nominal Input Voltage Green Standard Mode Power Consumption
Online Input Voltage Range
Frequency Range Total Amperage (all outlets) Voltage - On Battery Frequency - On Battery Ty pical Recharge Time Transfer Time Operating Temperature Storage Temperature Unit Dimensions
BG500
300 W 120 Vac
0.86 W
Default Setting: 92 V - 139 V Low Sensitivity Setting: 88 V - 142V High Sensitivity Setting: 96 V - 136 V
50 Hz - 60 Hz auto sensing
4.2 A (including UPS output) 115 Vrms ± 8% quasi sine wave 50 Hz/60 Hz ± 1 Hz 12 hours 10 ms, maximum 10 to 40C (50 to 104F)
-15 to 45C (5 to 113F) 29 × 19.1 x 5.4 cm (11.42 × 7.52 x 2.13 in)
Back-UPS Pro 500 BG500 120 Vac 1
Unit Weight 2.2 kg (4.85 lbs) Interface Web page
On Battery Runtime Battery Capacity Battery Voltage Battery Output Current Battery Weight Battery Dimensions
Supported OS
Go to: www.apc.com
2.3 Ah
13.2 V typical 40A continuous
0.53 kg (1.17 lbs)
7.74 x 15.23 x 4.16 cm (3.05 x 6 x 1.64 in) Windows XP, Windows Vista, Windows 7, Windows 8 and Mac OS X
(USB) Windows XP, Windows Vista, Windows 7 (software)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfere nce to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
EMI Compliance
– Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
Notice: This device complies with part 68 and part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation. “Locate the label on the bottom of this device that contains, among other
information, the FCC registration number and ringer equivalence number (REN) for this device. If requested, this information must be provided to the telephone company.”
USB Compliance
USB-If Basic Speed
Battery Replacement
Always recycle used batteries. For information on recycling a used battery, refer to the Battery Disposal
Li-ion
Replace used batteries with APC approved batteries. To order a replacement battery go to the APC by Schneider Electric Web site, www.apc.com.
Information sheet included with the replacement battery.
UPS Model Replacement Battery
BG500 APCRBC146-LI
Back-UPS Pro 500 BG500 120 Vac2
Lithium Ion Battery Safety Information
This product uses a lithium ion battery. The following safety rules must be followed when shipping the battery by air transportation.
1. Disconnect the battery and remove it from the UPS.
2. Do not pack more than two batteries in the same box.
3. Place the lithium ion battery handling label with power rating in watts, on the box if two batteries are
packaged in one box. Detailed battery specifications are listed above.
4. The following information must be included on the Air Waybill:
a. Lithium ion batteries or cells, NOT RESTRICTED as per PI966 Part 1. b. Handle the package with care!
Damage to the batteries can cause a fire hazard or the batteries may short circuit.
c. Contact telephone number
5. Contact the air cargo company for more detailed shipping information.
Back-UPS Pro 500 BG500 120 Vac 3

Operation

bu256
b

Product Overview

Front panel features
Power On/Off button - The Back-UPS is supplying conditioned AC power to connected equipment
Network Status - The Back-UPS is connected to the Ethernet network. Energy Management - Master and Smart outlets are enabled, saving power when the master device goes
into sleep or standby mode Watchdog - The Watchdog function is enabled on one or both Smart outlets
Replace Battery - The battery is not connected or is nearing the end of its useful life. Replace the battery.
Rear panel features
Backup Outlets
Smart Outlets
These outlets provide full-time surge protection for connected equipment from power surges even when the Back-UPS is turned off. Both outlets also have full time battery backup.
These outlets also provide full-time surge protection for connected devices. Smart Outlets are remotely manageable and can configurable.
Energy Management: To conserve ener gy the Smart outlet 1 and 2 will disconnect from AC power whenever the device plugged into the MASTER outlet is turned off or goes into Standby or Hibernation mode. Connect a printer, scanner or other noncritical devices that do not require battery backup protection.
Watchdog: The Watchdog feature automatically restarts networking gear when a loss of internet connectivity is detected. Suggested devices for connection to Smart Outlet 1 is a modem, and a wireless router for Smart Outlet 2. Combined wireless modem and router should be plugged into Outlet 1. The UPS will ping the configured remote IP address and if there is a failure for the duration of the test interval, the UPS will reboot the devices plugged into the Smart Outlets sequentially.
Configurable Backup: These configurable outlets can be configured as “Y es” or “No” in the device's web interface. When set to “No”, these configurable outlets do not provide battery backup to connected equipment. Connect a printer, scanner or other noncritical devices that do not require battery backup protection.
bu253d
Back-UPS Pro 500 BG500 120 Vac4
Master outlet Connect the master device to this outlet, in most cases, this will be the main computer.
T elephone Surge Protection
Mini USB port Use to connect the system to the desktop PC in order to monitor the Back-UPS battery condition.
Circuit breaker Use to reset the system after an overload condition has occurred causing the circuit breaker to trip
Building Wiring Fault indicator
Network Reset button
Network Management port
In addition to providing battery backup power and surge protection, this outlet will signal the Smart outlet to disconnect from AC power when the master device is either turned off or goes into Standby, Sleep, or Hibernation mode.
The Back-UPS protects equipment connected to a telephone line from power surges when connected through the Back-UPS telephone cable connectors.
The LED illuminates when there is no ground circuit, a neutral overload, or ther e is a reversed polarity in the building wiring. Protection is not guaranteed when the LED is illuminated. Have a qualified electrician correct the building wiring.
Use to reset UPS by pressing for more than 20 seconds, all network configuration and login information will be set to factory default when pressed for less than 20 seconds, it will reboot the network connection.
Use an Ethernet cable to connect a computer, modem or a router to this port. This port allows for the UPS to be managed remotely via a web based user interface.

Installation

UPS
For UPS installation instructions, refer to the Back-UPS Pro BG500 Installation Guide that is supplied with the UPS. The guide is also available on the enclosed User Manual CD and the APC by Schneider Electric Web, site at www.apc.com.

Energy Management

Energy Management function can be used to automatically reduce energy consumption. Plug your
computer into the Master outlet, and when it is turned OFF or goes into “sleep”, “standby”, “hibernation” mode, any peripherals plugged into the Smart Outlets like speakers, scanners, modem, router or printers, will also shut off automatically, eliminating needless electricity waste.
Notes: The Back-UPS ships with this Energy Management feature DISABLED. If you wish to use this feature, follow the instructions below.
Enable and Disable the Energy Management function. The Energy Management functio n of the Back-
UPS can be toggled between Enable and Disable through the Web page. Once enabled, the leaf indicator on the front panel will illuminate and extinguish once disabled. Refer to the "Web based Management Interface" on page 22 for instructions on how to access the Web page.

Watchdog Introduction

The Watchdog function is a feature for monitoring network equipment and automatically rebooting it
when it looses connectivity to the internet. In many cases when networking equipment loses connectivity a quick reboot is usually the fastest way to resolve the issue. With the BG500 this can be done automatically. The way it works is simple. Connect BG500 to your internet router using an Ethernet cable. Plug both your modem and wireless router to the Smart Outlets on the Back-UPS Pro. When configu red properly th e Back-UPS Pro will ping an IP address outside your network on the internet. When the Back-UPS Pro is not able to connect to that IP address it will reboot the modem and the router in an attempt to resolve the problem. No further user intervention is required. For more details follow the instructions in the Watchdog Settings on page 38 of this manual.
Back-UPS Pro 500 BG500 120 Vac 5

Connect Equipment

Connect a master device, such as a desktop computer or audio/visual receiver to the Master outlet. Connect peripheral devices such as a printer, speakers, or a scanner to the Smart Outlets.
Other required installations for the Back-UPS to funct ion properly include Ethernet cable connection, Telephone Protection In/Out connection, and battery pack installation.
Note: The UPS will charge to 90% capacity in the first three hours of normal operation. Do not
expect full battery runtime capability during this initial charge period.
1. Connect equipment to the outlets on the rear panel of the UPS.
Refer to "Smart Outlets" on page 20.
2. Connect the UPS to the building AC power. Connect the UPS to a two-pole, three-wire, grounded
source only.
3. To use the UPS as a
4. To turn on the UPS and all connected equipment. Press the
5. Follow the prompts to configure the UPS using the set up wizard the first time the UPS is turned on. Refer
to "Network Quick Configuration" on page 22.
Backup and Smart outlets
When the Back-UPS is receiving input power, all outlets, Master, Backup and both Smart Outlets will supply power to connected equipment.
MASTER ON/OFF switch, turn on equipment that is connected to the UPS.
ON/OFF button on the front panel of the UPS.
During a power outage or other AC problems, all outlets should be supplying backup power to each outlet. Smart Outlets can be configured to turn off outlets or be configured to be surge only . Here are the scenarios where a Smart Outlet is not supplying backup power or is off.
a. User has remotely turned off Smart Outlet b. Energy Management has been enabled and the load on the Master Outlet is below th e thresho ld
where Energy Managed Smart Outlets are turned off.
c. The W atchdog feature has been enabled and a loss of network connectivity has been detected and the
Smart Outlet is temporarily off as part of the reboot process.
d. The Smart Outlet has been configured to not provide Backup pow er and is in a surge only
configuration.
Back-UPS Pro 500 BG500 120 Vac6

Connecting the UPS by USB

bu305a
bu307a
By connecting the UPS to a computer by USB the operating system (W indows XP, Vista, 7, and 8 and Mac OS X) is able to view the UPS as a battery and is able to display charge capacity and charge state (on AC or on battery). Use the included cable to connect the USB cable on the back of the unit to an standard Type A USB port. The system should recognize the battery automatically. No additional software is needed. If the system previously had PowerChute Personal Edition (PCPE) installed there may be some driver conflict and users may have to make adjustments to the system in order for the operating system to properly recognize the UPS
Connecting by OS
Mac OS X
Turn on the UPS, connect the UPS to the Mac computer using the supplied USB cable.
1.Click System Preferences icon along the Dock.
bu304a

Click Energy Saver icon, you should see a UPS tab displayed in the dialog.
bu306a
Click UPS tab, check Show UPS status in the menu bar option. The Mac OS X will then display a UPS icon in the menu bar.
Back-UPS Pro 500 BG500 120 Vac 7
Windows 7
bu310a
bu312a
bu281a
bu311a
bu318a
bu325a
Turn on UPS and connect UPS to the W indows 7 computer via a USB cable. Click Start --> Control Panel --> Hardware and Sound. Under Devices and Printers group, click Device Manager. In the Device Manager window the UPS is listed as a HID UPS Battery device.
If the UPS is installed as a HID UPS Battery device, Windows 7 will display an UPS icon in the taskbar.
Updating the driver from APC UPS to HID UPS Battery
3.1 If device manager shows APC UPS device or APC Battery BackUP and in Power Options you cannot configure the system to shutdown when the UPS is on battery (Figures A - C) you have 2 options. 1 is to roll the driver back to HID UPS (Figures D, E and K) or 2 is to update the driver to HID UPS (Figures F - K)
As you see when APC UPS (figure A) or APC Battery BackUP (Figure B) are the loaded driver under Power Options (Figure C) there is no availability to configure shutdown while on battery.
Figure A
If the UPS is listed as an APC UPS Device. refer to step 3 in updating the device driver into HID UPS Battery. Otherwise proceed to step 4.
Figure B
Figure C
Back-UPS Pro 500 BG500 120 Vac8
Figure D Figure E
bu319a
bu313a
bu339a
bu324a
3.2 Option 1 - To roll the driver back: Go to Control Panel – Device Manager – Batteries – Select the APC UPS or APC Battery BackUP – Select Driver tab – select Roll Back Driver. The Driver will revert to HID UPS (Figures D & E).
Figure F Figure G
3.3 Option 2 – If you cannot roll the driver back (roll back is
grayed out) select Update Driver (Figure F) – Browse my Computer for Driver Software (Figure G) – Select Let me Pick from List of Device Driver on my Computer (Figure H) select HID UPS from list (Figure I)
bu338a
Figure H
Back-UPS Pro 500 BG500 120 Vac 9
Figure I Figure J
bu340a
bu342a
bu314a
bu315a
If the battery icon is not displayed in the system tray,
Figure K
click Control Panel, click Appearance and Personalization. Under the T askbar and S tart Menu group click Customize icons on the taskbar.
bu341a
3.4 You can now configure Power Options to shutdown when UPS is on Battery.
Click the dropdown box for the Power system icon, select On from the list. Now Windows sho uld display the battery icon in the system tray
Then click Turn system icons on or off.
.
Back-UPS Pro 500 BG500 120 Vac10
Windows XP
bu323a
bu325a
bu326a
1.Turn on UPS and connect UPS to the Windows XP computer via a USB cable.
Click Start --> Setting --> Control Panel --> System. In the System Properties window click the Hardware tab, then click Hardware Manager button.
bu324a
In the Device Manager window, expand Batteries. There should be a HID UPS Battery listing under Battery. Then you can skip following steps. If you see an APC UPS device instead of a HID UPS Battery device. You need to update the driver of UPS to the driver of HID UPS Battery
Updating the driver from APC UPS to HID UPS
Battery
4.1 Double click the APC UPS device. 4.2 From the Driver tab, click on the Update Driver
button
Back-UPS Pro 500 BG500 120 Vac 11
bu327a
bu328a
4.3 In the Hardware Update Wizard window, select Install from a list or specific location (Advanced), then click Next button.
bu329a
4.5 In the Hardware Update Wizard – Select the device driver you want to install for this hardware. Choose HID UPS Battery, then click Next button.
4.4 In the Hardware Update Wizard – Please choose your search and installation options window, select Don’t search. I will choose the driver to install, then click the Next button.
bu330a
4.6 In the Hardware Update Wizard – Completing the Hardware Update Wizard window, click Finish button.
Back-UPS Pro 500 BG500 120 Vac12
4.7 After completing above steps, Window XP will return
bu332a
bu333a
bu334a
to the HID UPS Battery Properties window. Click Close to finish updating driver.
Windows XP will display an icon in the taskbar .
bu331a
If the UPS is powered by AC source, Windows XP will not display an icon on the taskbar by default. You can change this behavior by clicking Start --> Setting --> Control Panel --> Power Options. In the Power Options Properties window, select Advanced tab, the check Always show icon on the taskbar.
If UPS is powered by AC source.
If UPS is powered by battery.
Back-UPS Pro 500 BG500 120 Vac 13
Configuring PC Shutdown
bu305a
bu307a
bu309a
Make sure the battery icon on the previous section is already present on the system tray / task bar of your operating system before proceeding to configuring the PC shutdown.
Mac OS X
Turn on the UPS, connect the UPS to the Mac computer using the supplied USB cable.
1.Click System Preferences icon along the Dock.
bu304a

Click Energy Saver icon, you should see a UPS tab displayed in the dialog.
To configure the shutdown options, click on the Shutdown Options button.
bu306a
Click UPS tab, check Show UPS status in the menu bar option. The Mac OS X will then display a UPS icon in the menu bar.
bu308a
After configuring the shutdown options, click Done.
Back-UPS Pro 500 BG500 120 Vac14
Windows 7
bu321a
bu322a
Right click the battery icon, select P ower Options.
On the Change settings for the plan page, click Change advanced power settings.
bu316a
bu317a
On the Select a power plan page, next to the plan you want to change, click Change plan settings.
bu320a
To configure the Windows 7 to shutdown itself, expand Critical battery action. From the drop down box next to On battery item, select Hibernate or Shutdown, and click OK button to save the settings. Then Windows will hibernate or shutdown itself when the percentage of battery remaining drops below the configured critical level.
On the Advanced settings tab, expand Battery, expand Low battery level, Reserve battery level, and Critical battery level. Change the percentage of battery remaining that you want for each level, and then click OK.
Back-UPS Pro 500 BG500 120 Vac 15