INSTALLATION AND OPERATING INSTRUCTIONS
THELIA 30 E
Note!
The boiler serial number is marked on the label attached to the top of the inner bulkhead. Refer to the 'Introduction' section page 3 for a description of the basic functions of the boiler. The 'Users' section describes how to safely operate the boiler.
USERS SECTION |
INSTALLATION SECTION |
Introduction .................................................... |
Page 3 |
Commissioning ......................................................... |
3 |
Controls & lighting .................................................... |
4 |
Draining ..................................................................... |
4 |
Servicing/maintenance .......................................... |
4 |
Introduction .................................................. |
Page 3 |
Dimensions ............................................................. |
5 |
Boiler schematic .................................................... |
5 |
Technical data ...................................................... |
6 |
Boiler connections ................................................. |
7 |
Piping system installation ...................................... |
7 |
Boiler location ........................................................ |
8 |
Heating system design ......................................... |
9 |
Domestic hot water system design..................... |
9 |
Boiler installation .................................................... |
9 |
Flue installation ............................................. |
10 - 11 |
Electrical installation ........................................... |
12 |
Commissioning ............................................. |
13 - 14 |
Operating safety devices .................................. |
14 |
Settings .................................................................. |
15 |
Changing gas type ............................................. |
15 |
Mandatory warning for CEE countries
Warning: This appliance was designed, approved and inspected to meet the requirements of the English market. The identification plate located on the inside of the appliance certifies the origin where the product was manufactured and the country for which it is intended.
If you see any exception to this rule, please contact your nearest Saunier Duval dealer. Thank you in advance for your assistance.
2
INTRODUCTION
The THELIA 30 E boiler is a wall mounted combination boiler providing central heating and instantaneous hot water.
The boiler is of the II 2H3 category for use with Natural Gas (G20) as distributed in the United Kingdom, or Butane (G30), Propane (G31) or Towns gas (G130).
Boilers burning LPG or similar gases MUST NOT be fitted in basements or below ground level.
The boiler has a fan assisted balanced flue which both discharges the products of combustion to and draws the combustion air from the outside of the room.
The boiler is suitable for top outlet flue connection only but, can be fitted with horizontal flue, vertical flue or twin-pipe flue. Refer to flue catalogue for further details.
Both the central heating and domestic hot water temperature are user adjustable from the boiler control panel.
COMMISSIONING
Domestic hot water demand always has priority over heating demand.
The boiler is designed for use as part of a sealed water central heating system with fully pumped circulation. The pump, expansion vessel and associated safety devices are all fitted within the boiler.
The boiler can be installed against either an external wall or on an adjacent inside wall, that is, the flue system will pass directly to the rear or to either side to the terminal fitted on the outside wall face.
The installation must be carried out by a competent person in accordance with the relevant requirements of The Building Regulations, The Water Byelaws, The Building Standards (Scotland) Regulations and any applicable local regulations.
These instructions should be carefully followed for the safe and economical use of your boiler.
Ancillary equipment
A range of flue accessories are available including vertical flues, twin-pipe flues, bends etc.
For further information contact your supplier.
Gas safety (Installation and Use) Regulations
In your interests and that of gas safety, it is the law that ALL gas appliances are installed and serviced by a competent person in accordance with the above regulations.
Gas leak or fault
If a gas leak or fault exists or is suspected, turn the boiler off and consult the local gas supply company or your installation/service company.
Boiler controls
The control panel, located at the lower front of the boiler casing, see diagram 1, allows the boiler to be started, shut down, controlled and monitored during use.
Flue
Do not obstruct the outside terminal of the boiler.
Diagram 1 |
A |
- Pressure gauge |
G - N/A on this model |
|||
|
||||||
|
B |
- |
Temperature gauge |
H |
- |
Safety shutdown warning light |
|
C |
- |
Reset button |
I |
- |
Domestic hot water temperature control |
|
D |
- |
N/A on this model |
J |
- |
Heating temperature control |
|
E |
- |
Mains 'ON' warning light |
K |
- |
'Summer/winter' selector |
|
F |
- |
Loss of water warning light |
L |
- |
N/A on this model |
A B C D E F G H I J K L
bar
0
Hab 031a
3
CONTROLS AND LIGHTING
Starting the boiler
Before starting the boiler check that:
•The gas meter tap is open.
•The boiler gas service cock is open.
•The boiler is connected to the electrical supply and turned on.
Setting to SUMMER mode (Hot water only)
•Turn the OFF/Summer/Winter' switch (K) to the 'Summer' position, see diagram 1.
•Turn the domestic hot water temperature control (I) to the desired setting, see diagram 1.
To obtain domestic hot water, open a hot water tap.
Hot water always has priority over central heating.
Setting to WINTER mode (Heating and hot water)
•Turn the OFF/Summer/Winter selector switch to
(K) to the 'Winter' position, see diagram 1.
•Turn the central heating temperature control (J) to the desired setting, see diagram 1.
•Turn the domestic hot water temperature control (I) to the desired setting, see diagram 1.
•Make sure that any external controls are calling for heat.
The heating system will begin to heat up.
To obtain domestic hot water, open a hot water tap.
Hot water always has priority over central heating.
DRAINING
Protection against freezing
If the boiler is to be out of use for any long periods during severe weather conditions, it is recommended that the whole system, including the boiler, be drained to avoid the risk of freezing.
If in doubt, consult your servicing company.
The THELIA 30 E boiler has a built in frost protection device that protects the boiler from freezing. If the boiler is to be left and there is a risk of frost, ensure that the gas and electrical supplies are left connected and that the OFF/Summer/Winter switch is left in the'Summer' or 'Winter' position.The frost protection device will light the boiler when the temperature of the boiler water falls below 6°C. When the temperature reaches 16°C, the boiler stops.
Note: This device works irrespective of any room thermostat setting and only protects the boiler. Always ensure that adequate frost protection is given to the entire system where necessary.
Draining and filling
Caution: The boiler is installed as part of a sealed system which must only be drained and filled by a competent person.
Heating safety valve
CAUTION: A safety valve with a discharge pipe is fitted to this boiler.
The valve MUST NOT BE TOUCHED except by a competent person. If the valve discharges at any time, switch the boiler off and isolate it from the electrical supply. Contact your installation/service company.
SERVICING/MAINTENANCE
To ensure the continued efficient and safe operation of the boiler, it is recommended that it is checked and serviced at regular intervals. The frequency of servicing will depend upon the installation conditions and usage but, in general, once a year should be enough.
Cleaning
The boiler casing can be cleaned with a damp cloth followed by a dry cloth to polish.
Do not use abrasive or solvent cleaners.
Boiler casing
CAUTION. Do not remove or adjust the casing in any way, as incorrect fitting may result in faulty operation. If in
4
DIMENSIONS
Diagram 2
The boiler is delivered in three separate packages:
-The boiler itself
-The fixing jig
-The flue system
For flue systems greater than 1 m long, remove the cup restrictor from the boiler flue outlet.
between 0,5 and 1,5 m fit diaphragm (a)
seal
a - diaphragm
393
260 |
|
217 |
|
Ø 100 |
80 |
889
520
Net weight : |
55 kg |
Gross weight : |
57 kg |
Hab 036
BOILER SCHEMATIC
Diagram 3 |
|
|||
1 |
- |
Bypass |
14 |
|
2 |
- |
Loss of water pressure switch |
||
|
||||
3 |
- |
Pump |
13 |
|
4 |
- |
Automatic air vent |
12 |
|
5 |
- |
Expansion vessel |
||
6 |
- |
Injector manifold |
11 |
|
7 |
- |
Ignition electrode |
||
8 |
- |
Expansion vessel filling valve |
|
|
9 |
- |
Overheat thermostat |
10 |
|
10 |
- |
Heat exchanger |
||
|
||||
11 |
- |
Fan |
9 |
|
12 |
- |
Air pressure switch |
||
13 |
- |
Automatic air vent |
8 |
|
14 |
- |
Flame sense electrode |
||
15 |
- |
Thermostatic valve |
|
|
16 |
- |
3-way valve |
7 |
|
17 |
- |
Gas valve |
|
|
18 |
- |
Water valve |
6 |
|
19 |
- |
Safety valve (3 bar) |
|
|
20 |
- |
Domestic hot water expansion |
|
|
|
|
vessel |
5 |
|
|
|
|
||
A |
- |
Heating return |
|
|
B |
- |
Cold water inlet |
4 |
|
C |
- |
Heating flow |
3 |
|
D |
- |
Domestic hot water flow |
||
E |
- |
Gas supply |
2 |
|
|
|
|
||
|
|
|
1 |
15
16
17
18
20
19
21
22
23
24
25
025Shy
5