Rockwell Automation 2198-H070-x-x User Manual

Installation Instructions
Kinetix 5500 AC Line Filters
Catalog Numbers 2198-DB08-F, 2198-DB20-F, 2198-DB42-F
Topi c Pag e
About the AC Line Filters 1
Important User Information 2
Before You Begin 3
Wire the AC Line Filter 4
AC Line Filter Specifications 7
Additional Resources 7

About the AC Line Filters

This publication provides installation instructions for the AC line filters used with Kinetix® 5500 servo drives. Use these instructions for installing and wiring your AC line filter. For more information on installing and wiring your Kinetix 5500 drive, refer to the Kinetix 5500 Servo Drives User Manual, publication 2198-UM001
2 Kinetix 5500 AC Line Filters
IMPORTANT

Important User Information

Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 Automation® sales office or online at http://www.rockwellautomation.com/literatu re/ between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibilit y or liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
WARNING: Identifies information about prac tices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
available from your local Rockwell
) describes some important differences
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard and recognize the consequences.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, drive or motor to alert people that dangerous voltage may be present.
BURN HAZARD: Labels may be on or inside the equipment, for example, drive or motor to alert people that surfaces may reach dangerous temperatures.
Identifies information that is critical for successful application and understanding of the product.
Rockwell Automation Publication 2198-IN003A-EN-P - July 2012
Kinetix 5500 AC Line Filters 3

Before You Begin

For general guidelines when laying out your panel and mounting your AC line filter, refer to the System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001.
For guidelines specific to your application, refer to the Kinetix 5500 Servo Drives User Manual, publication 2198-UM001
ATTENTION: To avoid personal injury or damage to equipment due to hazardous voltages, follow these guidelines when installing your AC line filter. NEC and local regulations always take precedence.
Disconnect mains power prior to installation.
Verify that the rated voltage is compatible with the local supply voltage.
Connect the earth ground connection first when making connections.

Install the AC Line Filter

Mount the line filter to the cabinet panel with hardware as specified in the table below.
Cat. No. Mounting Bolts
2198-DB08-F
2198-DB20-F
2198-DB42-F M6 (1/4x20) 4.5 (39.8)
Refer to the System Design for Control of Electrical Noise Reference Manual, publication
GMC-RM001,
performance.
M5 (#10-32) 2.0 (17.7)
for proper high-frequency (HF) bonding techniques to improve overall system
Tor que V alu e
N•m (lb•in)
Rockwell Automation Publication 2198-IN003A-EN-P - July 2012
4 Kinetix 5500 AC Line Filters
IMPORTANT
IMPORTANT
Bonded Cabinet Ground Bar
2198-DB08-F AC Lin e Filter
Input Fusing
Mains AC Input
Line
Load
Bonded Cabinet Ground Bar
2198-DBxx-F AC Lin e Filter
Input Fusing
Mains AC Input
Kinetix 5500 drive input power (IPD) connections for three-phase operation.
Line
Load
Kinetix 5500 drive input power (IPD) connections for single-phase operation.

Wire the AC Line Filter

Wire should be copper with 75 °C (167 °F) minimum rating. Phasing of main AC power is arbitrary and earth ground connection is required for safe and proper operation.
The National Electrical Code and local electrical codes take precedence over the values and methods provided.
When wiring the line filter for single-phase operation, do not make connections to the L3 terminals. Line and load designations must be observed to meet product specifications.
Wiring Examples for the AC Line Filter
240/480V
L1 L2 L3 PE
L1’ L2’ L3’ PE
L1 L2 L3
Rockwell Automation Publication 2198-IN003A-EN-P - July 2012
240V
L1 L2 L3 PE
L1’ L2’ L3’ PE
L1 L2 L3
Wiring Specifications
L1 L2 L3
Ø 6.0 (0.24)
167
(6.57)
8.5 (0.33)
R3.0 (0.12)
32
(1.26)
173
(6.81)
151
(5.94)
1.2
(0.05)
179
(7.05)
60.8
(2.39)
46
(1.81)
79
(3.11)
M5
Dimensions are in mm (in.).
Kinetix 5500 AC Line Filters 5
(1)
AC Line Filter Strip Length
mm (in.)
7.5 (0.30) 0.8 (7.1)2198-H008-ERS
12.0 (0.47)
Ter mi nal Tor que V alu es
N•m (lb•in)
2.0 (17.7)
(2)
Connects to
Term ina ls
Pin Signal
IPD-1 IPD-2 IPD-3 IPD-4
Kinetix 5500 Drive Cat. No.
2198-H003-ERS
2198-H015-ERS
2198-H025-ERS
2198-H040-ERS
2198-H070-ERS 2198-DB42-F
(1) The actual gauge of the input power wiring depends on the system configu ration. Consult your machine builder, the NEC, and applicable local
codes.
(2) Applies to installations with single-phase or three-phase input power.
Line Filter Cat. No.
2198-DB08-F
2198-DB20-F 9.0 (0.35)
Recommended Wire Size
2
, AWG
mm
1.5…4 (16…12)
1.5…6 (16…10)

AC Line Filter Dimensions

AC Line Filter Dimensions (catalog number 2198-DB08-F)
Rockwell Automation Publication 2198-IN003A-EN-P - July 2012
6 Kinetix 5500 AC Line Filters
Dimensions are in mm (in.).
Ø 6.5 (0.26)
R3.3
(0.13)
9.5 (0.37)
60
(2.36)
60
(2.36)
258
(10.16)
M6
240
(9.45)
129
(5.08)
1.2
(0.05)
272
(10.71)
73
(2.87)
162
(6.38)
Dimensions are in mm (in.).
AC Line Filter Dimensions (catalog number 2198-DB20-F)
217
R3.0
(0.12)
8.5 (0.33)
42
(1.65)
(8.54)
201
(7.91)
42 (1.65)
Ø 6.0 (0.24)
115.5 (4.55)
55
(2.16)
M5
1.2
(0.05)
AC Line Filter Dimensions (catalog number 2198-DB42-F)
227
(8.94)
93
(3.66)
Rockwell Automation Publication 2198-IN003A-EN-P - July 2012

AC Line Filter Specifications

Kinetix 5500 AC Line Filters 7
Cat. No.
2198-DB08-F
2198-DB20-F 20 9.3 5.2 1.63 (3.59)
2198-DB42-F 42 11.1 4.0 2.70 (5.95)
(1) Tolerance for this value is +10%.
Volta ge Rating
480V AC three-phase 50/60 Hz
Current Rating
A @ 50 °C (122 °F)
7.5 5.2 2.5 0.77 (1.70)
(1)
Power Lo ss
W
Leakage Current
mA
Weight, approx
kg (lb)

Additional Resources

These documents contain additional information concerning related products from Rockwell Automation.
Resource Description
Kinetix 5500 Servo Drives User Manual, publication 2198-UM001
System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001
EMC Noise Management DVD, publication GMC-SP004
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Product Certifications website, http://www.ab.com
Information on installing, configuring, starting, and troubleshooting your Kinetix 5500 servo drive system.
Information, examples, and techniques designed to minimize system failures caused by electrical noise.
Provides general guidelines for installing a Rockwell Automation industrial system.
Provides declarations of conformity, certificates, and other certification details.
Operating Tem per at ure
0…50 °C (32…122 °F)
You can view or download publications at http://www.rockwellautomation.com/literature
. To order paper copies of technical documentation, contact your local Allen-Bradley® distributor or Rockwell Automation sales representative.
Rockwell Automation Publication 2198-IN003A-EN-P - July 2012
Rockwell Automation Support
Rockwell Automation provides tec hnical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. You can also visit our Knowledgebase at http://www.rockwellautomation.com/knowledgebase forums, software updates, and to sign up for product notification updates.
For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect programs. For more information, contact your local distributor or Rockwell Automation representative, or visit
http://www.rockwellautomation.com/support/
Installation Assistance
If you experience a problem within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your product up and running.
United States or Canada 1 .440.646.3434
Outside United States or Canada
Use the Wor ldwi de Loc ator
http://www.rockwellautomation.com/support/americas/phone_en.html
Rockwell Automation representative.
New Product Satisfaction Return
Rockwell Automation tests all o f its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.
, you can find technical manuals, technical and application notes, sample code and
for FAQs, technical information, support chat and
sm
support
.
at
, or contact your local
United States
Outside United States Please contact your local Rockwell Automation representative for the return procedure.
Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process.
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002
Allen-Bradley, Kinetix, Rockwell Software, Rockwell Automation, and TechConnect are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 2198-IN003A-EN-P - July 2012
, available at http://www.rockwellautomation.com/literature/.
Copyright © 2012 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Loading...