The Program Transfer Module (PTM) is used tocreate and apply standard programming templates.
In addition, you can use the PTM on powered up, properly functioning Main Panels,which have been previously programmed
Note:
Note
To create a Programming Template by copying from a programmed WisDom:
Use a programmedWisDom system to create a Programming Template to be applied to other WisDomsystems. The programming on the WisDom is ready for copying.
To copy from a programmed WisDom system into the PTM:
1. Position the PTM on J1 located on the PCB of the back panel with the red
2. Remove the J9 default jumper from its position (located next to the tamper switch on the PCB ofthe
3. Accessthe main Installer Programming menuby pressing
4. Without making any changes, exit the main Installer Programming menu by pressing
Some displays will differ depending on panel type and version.
: If you download data from a WisDom you can
panel type. If the wrong data is uploaded, in some circumstances, panel damage may occur.
the row of terminals(See Fig 1).
front panel) on one pin and position it on both of the two pins.
mode.
to save. The LED on the Program Transfer Module flashes rapidly, and the keypad displays the
following:
The red LED flashes slowly.
ONLY
upload tothe same versionand
LED FACING AWAY
[9] [1]
from the regular operation
[0]
and press
from
Or
When the LED stops flashing rapidly, theWisDom beeps and displays the following
Then the display returns to the normal operationmode display.
Cont…
Page 1
5. Remove the PTM from J1.
6. Position the J9 jumper on one ofthe pins.
7. The PTM now contains a copy of the Main Panel’s configuration.
To load the Program Transfer module’s stored configuration into a WisDom:
1. Position the PTM on J1 located on the PCB of the back panel with the red LED FACING AWAYfrom the row of terminals (See Fig 1). The red LED flashes slowly.
2. Remove the J9 default jumper from its position (located next to the tamper switch on the PCB ofthe front panel) on one pin and position it on both of the two pins.
3. Momentarily remove the AC power from the WisDom.
4. Restore power to theWisDom. After a moment, the LED on the Program Transfer Module flashesrapidly, indicating that the information is being copied from the PTM to the WisDom system. The LCD keypad will display a blank screen.
When the LED stops flashing rapidly, theWisDom beeps, and its display returns to the normal operation mode display.
5. Remove the PTM from J1.
6. Position J9 on one of the pins.
[9] [1]
7. Accessthe main Installer Programming menuby pressing mode.
8. Without making any changes, exit the main Installer Programming menu by pressing [0]. The following display appears:
9. Confirm saving the data by pressing the
key. A short beep will sound and the following message
is displayed:
Then the keypad returns to the normal operationmode display, and the WisDom’s configuration now matches the PTM.
10. Reset its TIME and DATE, which were lost when power was removed. (Refer to theWisDom User’sManual).
from the regular operation
Page 2
ProSYS
ProSYS
This guide discusses the uses of the Program Transfer Module (PTM), how to copy from aprogrammedMain Panel into the PTM, and how to load the PTM’sstored configuration into a Main Panel.
The PTM is used to create and apply standard programming templates.
In addition, you can use the PTM on powered up, properly functioning Main Panels, which have been previously programmed.
Note:
If you download data from a ProSYS you can ONLY upload to the same version and panel type.
If the wrong data is uploaded, in some circumstances, panel damage may occur.
To create a Programming Template by copying from a programmed Main Panel:
Use a programmed Main Panel tocreate a Programming Template to be applied to other Main Panels.The programming on the Main Panel is ready for copying.
To install a Programming Template on a Main Panel:
Use an existing Programming Template on a PTM to install programming on a Main Panel. At least one LCD keypad must be installed on the Main Panel.
To copy from a programmed Main Panel into the PTM:
8. Position the PTM on J1, J5 or J8 on the Main Panel (See Fig 2), with the red terminals on the Main Panel. The red LED flashes slowly.
9. Remove the J2 jumper from its position on one pin of the J2 connector (See Fig 2).
10.Position the J2 jumper on both of the two pins ofthe J2 connector.
11.From an LCD keypad, access the main Engineer Programming menu by pressing optionof themain Engineer Programming menu is displayed.
12.Without making any changes,exit the mainEngineer Programming menuby pressing [0]and
The LED on the Program Transfer Module flashes rapidly, and the keypad displays the following:
When the LED stops flashing rapidly, the keypad beeps and displays the following:
Page 3
/ .
(This message will appear only in the ProSYS UKversion)
LED FACING
[7] [1].
the row of
The first
/
Cont…
Then the keypad returns to the normal initial display.
6. Remove the PTM from J1, J5 or J8 and remove the J2 jumper.
7. Position the J2 jumper on one of the pins of the J2 connector.
8. The PTM now contains a copy of the Main Panel’s configuration.
To load the Program Transfer module’s stored configuration into a Main Panel:
1. Position the PTM on J1, J5 or J8 on the Main Panel (See Fig 2), with the red LED FACING the row of terminals on the Main Panel. The red LED flashes slowly.
2. Remove the J2 jumper from its position on one pin of the J2 connector (See Fig 2).
3. Position the J2 jumper on both of the two pins ofthe J2 connector.
4. Momentarily remove all power from the Main Panel (both AC and Standby Battery).
5. Restore all power to the Main Panel. After a moment, the LED on the Program Transfer module flashes rapidly, indicating that the information is being copied from the PTM to the Main Panel. TheLCD keypad displays the following:
When the LED stops flashing rapidly, the keypad beeps, and its display returns to the normal initial display.
6. Remove the PTM fromtheJ1, J5 or J8 connector and remove the J2jumper.
7. Position the J2 jumper plug on one of the pins ofthe J2 connector.
8. From an LCD keypad, access the main Engineer Programming menu by pressing
The firstoption of the main Engineer Programming menu isdisplayed
.
9. Without making any changes, exit the main Programming Menu by pressing [0] and
/ / .
The LED on the Program Transfer Module flashes rapidly and the keypad displays the following:
.
10. Press
The keypad beeps and displays the following:
[7] [1].
(This message will appear only in the ProSYS UK version)
(This message will appear only in the ProSYS UK version)
Then the keypad returns to the normal initial display, and the Main Panel's configuration now matches the PTM.
11. Reset its Time and Date, which were lost when power up was removed (Refer to the ProSYS User'sManual)
Contacting RISCO Group:
RISCO Group is committed to customer service and product support. You can contact us through our website (www.riscogroup.com) or at the following telephone and fax numbers:
United Kingdom
Tel: +44-161-655-5500 technical@riscogroup.co.uk
Poland
Tel: +48-22-500-28-40support-pl@riscogroup.com
Italy
Tel: +39-02-66590054support@riscogroup.it
USA
Tel: +305-592-3820support-usa@riscogroup.com
Spain
Tel: +34-91-490-2133support-es@riscogroup.com
Brazil
Tel: +55-11-3661-8767 support-br@riscogroup.com
France
Tel: +33-164-73-28-50support-fr@riscogroup.com
China
Tel: +82-21-52-39-0066 support-cn@riscogroup.com
Belgium
Tel: +32-2522-7622support-be@riscogroup.com
Israel
Tel: +972(0)3-963-7777 support@riscogroup.com
5IN128EE B 12/08
Page 4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.