OLYMPUS C-2 TECHNICAL INFORMATION TID-C2-E001

TECHNICAL INFORMATION
NO. TID-C2-E001
DATE December.10.2001
SUBJECT: Version up of Firmware
Product name: C-2
The latest firmware:
OLD VERSION NEW VERSION SERIAL NUMBER
D-230(U),C-2(E),C-2(G) V973u-74 V973u-75
Please refer to repair article for a procedure of rewriting firmware.
h These serial numbers are under inquiry.
Change contents (Reason): It changed in order to correct the fault to which the color of the picture of the 1st (left-hand side) sheet becomes unusual by performing color conversion of a picture of the 1st sheet by the white balance of the 2nd sheet when a photograph is taken in synthetic two-shot mode depending on a photography scene.
Version up procedure:
h h
1. The binary data of the latest firmware is changed with “firmware.bin” and into smart media. But format smart media into C-2 and make directory “firmware” copy from binary data. (Make F/W card)
2. Insert the F/W card for C-2 and turn on the camera at play mode.
3. TFT-LCD was showed F/W version and inquire of rewriting of F/W. Then select “YES” (Character is changed green) and after pressing “OK”, rewriting of F/W is started automatically.
4. During the rewriting of F/W, SELF-RED is turned on and showed “EXCHANING” on TFT-LCD. It will take about 2 minutes but please do not operate any key and turn off power. It might have damaged camera body and F/W.
5. After the rewriting of F/W, TFT-LCD was showed as same as procedure 3. Then confirm new version of F/W (example: V973-75 =NTSC(GUI:JAPANESE)) and turn off power after selecting “NO”. (The discrimination of countermeasure is not showed due to confirm easily.)
OLYMPUS OPTICAL CO. ,LTD TOKYO
Loading...