OLYMPUS C-2 TECHNICAL INFORMATION TID-C2-E002

TECHNICAL INFORMATION
NO. TID-C2-E002
DATE 2001/12/21
SUBJECT: The countermeasure for short circuit of PL wire on the
lens
Contents:
A P tape and Spacer Front are attached as a countermeasure for short circuit of PL wire.
C-2/D-230
PL wire countermeasure execution classification:
Destination Serial Number
C-2 (J)
D-230
C-2 (E)
C-2 (G)
SNo. 209115631 ~ SNo. 209310001 ~ SNo. 209509001 ~ SNo. 209200001 ~ SNo. 207105001 ~ SNo. 207310001 ~ SNo. 207502911 ~ SNo. 207200001 ~ SNo. 208315001 ~ SNo. 208500001 ~ SNo. 208200001 ~ SNo. 211300001 ~
Countermeasure :
When you received repair camera which has this problem, the following P tape and Spacer Front are attached.
VE398800 : P Tape VC178800 : Spacer Front
Modified Spare part :
Front Cover is supplied that a spacer Front is attached. A lens is supplied that a P tape is attached too.
VC169700[C-2(J),C-2(E),C-2(G)]/ VC171400[D-230]: Front Cover
Marking :
OLYMPUS OPTICAL CO.,LTD TOKYO
Spacer Front application position :
P tape application position :
Make the space of LW.
Between the LW s, more than 1mm.
The first sheet P tape
The second sheet P tape
Have attached the first sheet of P tape.
P tape (the first sheet)
How to modify LW of PL The space of the LW is left more than 1mm. Don't tear off coating of the LW when you leave it.
Make the space of P tape.
The second sheet of P tape attaching method Protrusion to the bobbin isn't acceptable. It doesn't pile up with the first sheet of tape. Dotted line central centering
Check Between LWs are left more than 1mm.
OLYMPUS OPTICAL CO.,LTD TOKYO
Loading...