Marantz RC-3001 Service Manual

Page 1
Service
RC3001
RC3001 /
E1B
Manual
RC3001
Remote Controller
RX3001
TABLE OF CONTENTS
SECTION PAGE
1. TECHNICAL SPECIFICATIONS ........................................................................................... 1
2. PARTS LIST .......................................................................................................................... 2
3. INSTALLING Wizz.it 3 ........................................................................................................ 4
Please use this service manual with referring to the user guide ( D.F.U. ) without fail.
RC3001
Part no. 90M43CW855010
MZ
Page 2
MARANTZ DESIGN AND SERVICE
USA
MA R A NTZ A M ERIC A , INC
100 CORPORATE DRIVE MAHWAH, NEW JERSEY 07430 USA
EUROPE / TRADING
MA R A NTZ E U ROPE B . V.
P. O. BOX 8744, BUILDING SILVERPOINT BEEMDSTRAAT 11, 5653 MA EINDHOVEN THE NETHERLANDS PHONE : +31 - 40 - 2507844 FAX : +31 - 40 - 2507860
KOREA
D&M SALES AND MARKETING KOREA LTD.
CHUNG JIN B/D., #1001, 53-5, WONHYORO 3 GA, YONGSAN-GU, SEOUL, 140-719, KOREA PHONE : +82 - 2 - 323 - 2155 FAX : +82 - 2 - 323 - 2154
CANADA
D& M C ANA D A INC.
5-505 APPLE CREEK BLVD. MARKHAM, ONTARIO L3R 5B1 CANADA
JAPAN
D&M BUILDING, 2-1 NISSHIN-CHO, KAWASAKI-KU, KAWASAKI-SHI, KANAGAWA, 210-8569 JAPAN
D& M H old i n gs In c .
CHINA
MARANTZ S HA NG HA I TR AD IN G LT D.
ROOM.506 SHANGHAI LIGHT INDUSTRY MANSION 1578 NANJING (WEST) ROAD SHANGHAI CHINA TEL : 021 - 6248 - 1064 FAX : 021 - 6248 - 3565
Using superior design and selected high grade components, Only original
MARANTZ
parts can insure that your
MARANTZ
MARANTZ
product will continue to perform to the specifications for which
company has created the ultimate in stereo sound.
it is famous. Parts for your
MARANTZ
ORDERING PARTS :
equipment are generally available to our National Marantz Subsidiary or Agent.
Parts can be ordered either by mail or by Fax.. In both cases, the correct part number has to be specified. The following information must be supplied to eliminate delays in processing your order :
1. Complete address
2. Complete part numbers and quantities required
3. Description of parts
4. Model number for which part is required
5. Way of shipment
6. Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void.
NOTE ON SAFETY :
Symbol Fire or electrical shock hazard. Only original parts should be used to replaced any part marked with symbol . Any other component substitution (other than original type), may increase risk of fire or electrical shock hazard.
安全上の注意:
がついている部品は、安全上重要な部品です。必ず指定されている部品番号のものを使用して下さい。
SHOCK, FIRE HAZARD SERVICE TEST :
CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary AC
cord connector pins ( with unit NOT connected to AC mains and its Power switch ON ), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verified before it is return to the user/customer.
Ref. UL Standard No. 60065.
In case of difficulties, do not hesitate to contact the Technical
Department at above mentioned address.
070719MZ
Page 3
1. TECHNICAL SPECIFICATIONS
SPECIFICATIONS
RC3001
LCD Resolution
.............................................“11x81pixel x6 line
................................................9x81pixel x1line”
Backlight .............................................. EL back light
Transmission ..............................................IR or RF
Learning .......................... Capability: MAX 1000code
Operating/ learning IR frequency range
.....................................................Up to 455kHz
RF carrier frequency ............................... 433.92MHz
Rechargeable battery pack
.............................NiMH Battery Pack 700 mAh
Interface ..
USB 2.0 connection with USB bus power supply
Memory Size ...................................... 4M bit (512kB)
Dimensions (W x H x L)
............... 54 x 228 x 25 mm (2-3/16 x 9 x 1ins.)
Unit Weight (With Batteries) ................ 210g (0.5lbs)
228mm (9 ins.)
DC 9V
25mm
(1ins.)
54mm (2-3/16 ins.)
228mm (9 ins.)
ENGLISH
RX3001
RF carrier frequency ............................... 433.92MHz
Operating/ learning IR frequency range
.....................................................Up to 100kHz
IR emitter output ...................................................x6
Dimensions (W x H x L) ...
102 x 63.5 x 27 mm (4-1/16 x 2-1/2 x 1-1/8 ins.)
Unit Weight ............................................ 90g (0.2lbs)
AC Adapter
Power Supply ................. 100 V-240 V AC / 50-60 Hz
Power Output .......................................DC9V 800mA
ENGLISH
RX3001
MAX186mm (7-3/8ins.)
MIN105mm (4-3/16ins.)
27mm
(1-1/8ins.)
MAX190mm (7-1/2ins.)
MIN109mm (4-5/16ins.)
102mm (4-1/16ins.)
63.5mm (2-1/2ins.)
DC 9V
RX3001
RF carrier frequency ............................... 433.92MHz
Operating/ learning IR frequency range
.....................................................Up to 100kHz
IR emitter output ...................................................x6
Dimensions (W x H x L) ...
102 x 63.5 x 27 mm (4-1/16 x 2-1/2 x 1-1/8 ins.)
Unit Weight ............................................ 90g (0.2lbs)
AC Adapter
Power Supply ................. 100 V-240 V AC / 50-60 Hz
Power Output .......................................DC9V 800mA
ENGLISH
5. RESET
If the RC3001 is not operating properly, use the procedure below to perform a reset (restart). Performing a reset does not erase the settings in the RC3001.
1 .
Remove the battery case cover.
2 .
Use a paper clip or other object to press the
reset button in the reset hole as shown in the fi gure below to reset the RC3001.
Note:
Perform the reset with the battery pack loaded.
RESET
1
Page 4
2. PARTS LIST
1
2
3
4 5
6
Double side adhesive tape
2
Page 5
Page 6
3. INSTALLING Wizz.it 3
INSTALLING Wizz.it 3
1 .
At fi rst, you download the software Wizz.it 3 from the Home Entertainment section of your region in
Marantz Website http://www.marantz.com.
2 .
Open the downloaded fi le in your PC and follow the on screen instructions to install the editor.
Notes:
You can install Wizz.it 3 together with other Marantz editors.
The fi les of Wizz.it 3 are automatically placed in a separate directory.
CUSTOMIZING THE CONFIGURATION FILE
During the installation of the editor, one confi guration fi le was also saved on your PC. There is one default confi guration fi le which you can start from to create a custom confi guration fi le (CF) (defaultRC3001.mcf). The default CF is constructed in such a way that they can be easily adjusted to the needs of every customer.
• This fi le contains the main Marantz remote control codes for enabling control of Marantz products with the default settings.
CONNECTIONS
CONNECT PC AND REMOTE CONTROLLER
1. The attached USB cable connects to the USB port of remote controller and the USB port of your
PC
2.
Open the USB Device wizard menu in your PC automatically.
3.
Select the automatic scanning of USB driver or select the location of USB driver.
The location of RC2001_3001 USB driver
C:\Program Files\Marantz\Marantz Wizz.it 3
Note:
The USB driver of RC2001 and RC3001 does not take the certifi cation of Microsoft.
However, you can use it in your PC.
4