PX SERIES LOW VOLTAGE LANDSCAPE AND SWIMMING POOL/SPA LIGHT TRANSFORMERS
INSTALLATION OPERATION & SERVICE MANUAL
Model: PX100 and PX100S - 100 W Transformers
INPUT: 120 VAC, OUTPUT: 12 VAC or 13 VAC
Model: PX300 and PX300S - 300 W Transformers
INPUT: 120 VAC, OUTPUT: 12 VAC, 13 VAC or 14 VAC
Suitable for direct connection to underwater lights and for Indoor/Outdoor installations except in CANADA - Low Voltage Landscape Lighting installation - Outdoor only.
Read and follow the safety instructions listed below and other basic safety precautions before installation or operation of this transformer and other associated equipment.
WARNING Risk of Fire or Electrical Shock
•If installation involves running wire through a building structure, special wiring methods are needed.
•Do Not submerge transformer.
•Do Not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
•Select cable for each secondary output in accordance with tables in this manual.
•Select power source by combining bulb wattage.
•For landscape lighting appliances, low voltage cable shall be buried a maximum of 6 inches (15.2 cm) in order to connect to the main low voltage cable.
GENERAL INFORMATION
These Safety Transformers are specifically designed to supply 12 volts to pool/spa lights, submersible fixtures
and outdoor garden lights. The built-in circuit protection will disconnect power to the transformer in case of defect or overload. These transformers are suitable for direct connection to underwater Pool and Spa lights.
SPECIFICATIONS
Enclosure Size: 7 1/4” (19.4 cm) high x 5 1/4” (13.3 cm) wide
x 4 1/2” (11.4 cm) deep. Mounting brackets top and bottom. Enclosure Type: (A) 0.048” corrosion resistant steel with
electrostatically applied beige coating. (B) 0.036” stainless
steel.
Knockouts: Total of ten 1/2”-3/4” combination.
(4) bottom, (2) right side, (2) left side, (2) back.
Model |
Input |
Secondary Output |
Enclosure |
|
|
60 Hz. |
|
|
Type |
|
Lamp Watts(W)* |
Voltage (VAC) |
||
|
|
|
||
|
|
|
|
|
PX100 |
120 VAC 1 A Max. |
100 Max. |
12 or 13 |
A |
PX100S |
120 VAC 1 A Max. |
100 Max. |
12 or 13 |
B |
PX300 |
120 VAC 3 A Max. |
300 Max. |
12, 13 or 14 |
A |
PX300S |
120 VAC 3 A Max. |
300 Max. |
12, 13 or 14 |
B |
* Any combination of bulbs, any tap.
1
Pool/Spa Underwater Lighting Application
INSTALLATION
For field wiring information, please refer to the instructions attached to inside of front cover.
•Make sure that all unused taps (leads) are separately insulated.
•Use the following tables as a guide to determine the correct wire size.
•The voltage at lamp terminals after installation should be 12 ± 0.3 VAC.
•Voltages above 12.3 VAC at the light may cause the internal safety fuse of the transformer to switch off and on. To prevent this from happening follow chart below for correct voltage and wire gauge selection.
1.Select power source by combining Bulb wattage.
2.Determine length of cable run(s).
3.Determine wire gauge needed to deliver necessary power.
4.Connect cable to output tap of transformer given in table.
120 VAC Primary Input - 100 W Output
Distance* |
2#6AWG |
2#8AWG |
2#10AWG |
2#12AWG |
2#14AWG |
Feet |
|
|
|
|
|
5 ft. |
12 VAC |
12 VAC |
12 VAC |
12 VAC |
12 VAC |
30 ft. |
12 VAC |
12 VAC |
12 VAC |
13 VAC |
13 VAC |
60 ft. |
12 VAC |
12 VAC |
13 VAC |
13 VAC |
|
90 ft. |
12 VAC |
13 VAC |
13 VAC |
|
|
120 ft. |
13 VAC |
13 VAC |
|
|
|
150 ft. |
13 VAC |
13 VAC |
|
|
|
180 ft. |
13 VAC |
|
|
|
|
210 ft. |
13 VAC |
|
|
|
|
240 ft. |
13 VAC |
|
|
|
|
|
|
|
|
|
|
* Length of run to light from transformer.
120 VAC Primary Input - 300 W Output
Distance* |
2#6AWG |
2#8AWG |
2#10AWG |
2#12AWG |
Feet |
|
|
|
|
5 ft. |
12 VAC |
12 VAC |
12 VAC |
12 VAC |
10 ft. |
12 VAC |
12 VAC |
12 VAC |
13 VAC |
20 ft. |
12 VAC |
12 VAC |
13 VAC |
13 VAC |
30 ft. |
12 VAC |
13 VAC |
13 VAC |
14 VAC |
40 ft. |
13 VAC |
13 VAC |
14 VAC |
|
50 ft. |
13 VAC |
13 VAC |
14 VAC |
|
60 ft. |
13 VAC |
14 VAC |
|
|
70 ft. |
13 VAC |
14 VAC |
|
|
80 ft. |
13 VAC |
14 VAC |
|
|
90 ft. |
14 VAC |
|
|
|
100 ft. |
14 VAC |
|
|
|
110 ft. |
14 VAC |
|
|
|
* Length of run to light from transformer.
LANDSCAPE LIGHTING APPLICATIONS
•Use only CSA or UL certified low-voltage cable.
•Low voltage cable shall be buried a maximum 6 inches (15.2 cm) in order to connect to the main low voltage cable.
Transformer Wattage (W) |
Minimum Gauge AWG |
|
|
300 |
12 |
|
|
100 |
16-14-12 |
|
|
LIMITED ONE-YEAR WARRANTY
If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a warranty claim online at www. intermatic.com. This warranty is made by: Intermatic Incorporated, Customer Service 7777 Winn Rd., Spring Grove, Illinois 60081-9698. For warranty service go to: http://www. Intermatic.com or call 815-675-7000.
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.
INTERMATIC INCORPORATED, SPRING GROVE, IL 60081-9698 http://www.intermatic.com
2