MODEL: T104R

LR3730

24 HR. DIAL TIME SWITCH (DPST)

IN TYPE 3R RAINPROOF ENCLOSURE, SUITABLE FOR POOL EQUIPMENT CONTROL IF INSTALLED 5 FT. OR MORE FROM EDGE OF POOL.

40 AMP. RESISTIVE EACH POLE 120-480 VOLT AC;

40 AMP. INDUCTIVE OR TUNGSTEN OR 1000 VA PILOT DUTY EACH POLE 120V-277V AC; 2 HP (24 FLA)-120V AC; 5 HP (28 FLA)-240V AC.

CLOCK MOTOR: 208-277 VOLTS - 60 HZ.

CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO ORDER REPLACEMENT, INDICATE ART NO. (WG--) ON MOTOR COVER.

TIME

DIAL

TIME POINTER

OFF TRIPPER

MANUAL

LEVER

ON TRIPPER

WIRING

DIAGRAM

240 V 2 WIRE AND GROUND

 

A

1

2

3

4

 

GR

 

 

 

 

240V

LINE 1

 

 

 

 

SUPPLY LINE 2

 

 

 

GROUND

 

 

 

 

 

277/480 VOLT CONNECT MOTOR LEADS TO TERMINALS “A” AND 1 AND SUPPLY NEUTRAL TO TERMINAL “A”.

CLOCK

MOTOR

TO LOAD(S)

WIRING INSTRUCTIONS: To wire switch follow diagram above. Use solid or stranded COPPER only wire with insulation to suit installation. See gauge selection table for normal service applications. To make power connections remove 1/2 inch of insulation from wire ends. Insert bare ends of wire under the pressure plate of terminals. Use 3/16 or larger screwdriver to tighten terminal screws firmly. (25 lb-in minimum).

REPLACE INSULATOR BEFORE TURNING ON ELECTRICITY.

MINIMUM

MAX.

MIN.

75°C INSULATION MAX. MOTOR

PRESSURE PLATE

COPPER

LOAD

INSUL-

 

 

LOAD (HP)

 

WIRE SIZE

(AMP)

ATION

 

SINGLE PHASE

3 PHASE

TERMINAL SCREW

(AWG)

 

TEMP (°C)

 

120 V.

240 V.

208 V.

240 V.

 

 

 

 

 

14

15

60

 

1/2

2

 

 

MAKE SURE WIRE

12

20

60

 

1

2 1/2

N/A

N/A

INSULATION CLEARS

10

30

60

 

2

3

 

 

PRESSURE PLATE

8

40

75

 

-

5

 

 

 

PROGRAMMING INSTRUCTIONS

1.TO SET “ON” AND “OFF” TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. For additional tripper pairs on CLOCK-DIAL order 156T1978A.

2.TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either direction and align the exact time-of-day on the CLOCKDIAL (the time now, when switch is being put into operation) to the pointer. DO NOT MOVE POINTER.

OPERATING INSTRUCTIONS

TO OPERATE SWITCH MANUALLY: Move MANUAL LEVER below CLOCK-DIAL left or right as indicated by arrows. This will not effect next operation.

IN CASE OF POWER FAILURE, reset CLOCK-DIAL to proper time-of-day. See programming instructions.