Intermatic T103R Owner's Manual

0 (0)
Intermatic T103R Owner's Manual

MODEL: T103R

LR3730

 

24 HOUR DIAL TIME SWITCH (DPST)

IN TYPE 3R DUSTPROOF RAINPROOF ENCLOSURE, SUITABLE FOR POOL

EQUIPMENT CONTROL IF INSTALLED 5 FT. OR MORE FROM EDGE OF POOL.

40 AMP. RESISTIVE, INDUCTIVE TUNGSTEN OR 1000V.A. PILOT DUTY 120/208/240 VOLT AC;

2 H.P. (24 FLA) - 120 V. AC; 5 H.P. (28 FLA) - 240V. AC CLOCK MOTOR: 110-125V. 60 HZ.

CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO ORDER REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.

 

ON

TYPICAL

 

 

 

CLOCK

WIRING

 

CLOCK

DIAL

TRIPPER

DIAGRAM

MOTOR

TIME

 

 

 

 

 

POINTER

 

120/240

NEUT. A 1 2

3 4

 

OFF

 

 

 

VOLT

 

 

 

TRIPPER

 

LINE 1

 

 

 

3 WIRE

 

TO

MANUAL

 

 

 

SUPPLY LINE 2

 

LOADS

LEVER

 

GROUND

 

 

GR.

 

 

FIGURE 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WIRING INSTRUCTIONS: To wire switch follow diagram above. Use solid or strand COPPER only wire with insulation to suit installation. See gauge selection table for normal service applications. To make power connections remove 1/2 inch of insulation from wire ends. Insert bare ends of wire under the pressure plate of terminals. Use 3/16 or larger screwdriver to tighten terminal screws firmly. (25 lb-in minimum).

REPLACE INSULATOR BEFORE TURNING ON ELECTRICITY.

MINIMUM

MAX.

MIN.

75° INSULATION MAX. MOTOR

COPPER

LOAD

INSUL-

 

LOAD

(HP)

 

WIRE SIZE

(AMP)

ATION

SINGLE

PHASE

3 PHASE

(AWG)

 

TEMP (°C)

120V

240V

240V

240V

14

15

60

1/2

2

 

 

12

20

60

1

2 1/2

N/A

N/A

10

30

60

2

3

8

40

75

 

5

 

 

 

 

 

 

 

 

 

PRESSURE PLATE TERMINAL SCREW

MAKE SURE WIRE INSULATION CLEARS PRESSURE PLATE

PROGRAMMING INSTRUCTIONS

TO SET “ON” AND “OFF” TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. For additional tripper pairs on CLOCK-DIAL order 156T1978A.

TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either direction and align the exact time-of-day on the CLOCK-DIAL (time now, when switch is put into operation) to TIME POINTER. DO NOT MOVE

POINTER.

OPERATING INSTRUCTIONS

TO OPERATE SWITCH MANUALLY: Move MANUAL LEVER below CLOCK-DIAL left or right as indicated by arrows. This will not effect next operation.

IN CASE OF POWER FAILURE, reset CLOCK-DIAL to proper time-of-day. See programming instructions.

INTERMATIC INCORPORATED

SPRING GROVE, ILLINOIS 60081-9698

154--01002

Loading...