Recommended Installation, Maintenance
and Inspection Instructions
MagBreak Reconnectable Safe-T-Break®
MagBreak STB
RECONNECT
Model # |
8630 |
9911 |
10328 |
10331 |
8330 |
8631 |
9920 |
10329 |
|
8331 |
9910 |
9921 |
10330 |
|
Important safety instructions - save these instructions in a readily accessible location.
WARNING This device separates at less than 225 lbf / 1000.9 N pull force!
INSTALLATION INSTRUCTIONS
NOTE: Prior to installation, it shall be determined that such pull force will not damage the hose assembly or dispensing device. The dispensing device must be securely bolted to dispensing island.
1.Attach scale to where the Safe-T-Break® will be installed. Apply 225 lbf / 1000.9 N pull force at various angles and check dispenser and hose for damage. Refer to UL 567 for details. If no damage occurred, release pull and complete installation.
2.Install Safe-T-Break® in the direction of the flow arrows, in high hose dispenser locations only and between the hose sections. The inlet whip hose should be 9 inches long.
3.Use pipe thread sealant (not Teflon tape) approved for gasoline on the male threads of the hose section.
4.Tighten approximately 1 to 2 turns past hand tight - do not overtighten.
5.Pressurize system and visually inspect for leaks.
DO NOT OVERTIGHTEN. DO NOT WRENCH ACROSS COUPLING.
DO NOT INSTALL DIRECTLY TO THE DISPENSER.
RECONNECT INSTRUCTIONS
•Shut off dispenser and relieve line pressure.
•Before Reconnecting:
∙Inspect the entire dispensing system and Safe-T-Break® for damage.
∙Conduct pull test for dispenser integrity (see Step 1 of Installation Instructions above).
∙Lubricate o-rings with light oil.
•Reconnecting:
∙Push male half into female half and twist ends until unit snaps together and locks. Confirm the two halves are locked and will not rotate by rotating the two hex ends in opposite
directions by hand.
∙Replace Safe-T-Break® if doesn't readily reconnect.
•After Reconnected:
∙Check reconnected Safe-T-Break® for proper engagement.
∙Check for electrical conductivity.
∙Check for leaks at Safe-T-Break®.
∙Check for proper flow of fuel.
ONLY PROPERLY TRAINED PERSONNEL SHOULD RECONNECT SAFE-T-BREAKS®.
TESTING / MAINTENANCE / INSPECTION
Daily
•Check for leaks / stains.
•Check for damage.
Monthly
• Check "remove by" date.
Annually
•Conduct pull test – disconnect, inspect interior for debris, discoloration, and foreign matter.
•Check for electrical continuity.
•All drive aways, maintenance and inspection activities must be logged using the serial number of the individual product.
•Apply city, state, or federal testing regulations as appropriate.
ANY TEST / INSPECTION FAILURE REQUIRES IMMEDIATE EQUIPMENT REPLACEMENT OR REMOVAL FROM SERVICE.
MADE IN THE USA
Husky Corporation • 2325 Husky Way • Pacific, MO 63069 • Phone: (800) 325-3558 • Fax: (636) 825-7300 • www.husky.com
Page 1 |
009339-3 02/2013 |
ALWAYS ADHERE TO INSTALLATION / USAGE INSTRUCTIONS AND WARNINGS.
Improper use may result in injury, damage, or hazardous spill.
GENERAL WARNINGS / INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC |
|||
SHOCK OR INJURY TO PERSONS: |
• Always place containers on the ground |
||
• Use of equipment is at individuals’ own risk. |
|||
before filling. |
|||
• Always abide and adhere to city, state, and |
|||
• Always discharge static electricity before |
|||
federal regulations regarding use and |
|||
using or servicing equipment by touching |
|||
installation of dispensing equipment. |
|||
a metal part of the dispenser before and |
|||
• Always follow the dispenser manufacturer’s |
|||
after fueling vehicle. |
|||
instructions. |
|
||
|
• Never smoke within 20 ft / 6.1 m of |
||
• Always turn off all power to dispenser |
|||
dispensers. |
|||
during maintenance and inspection activities. |
|||
• Never keep in service past recommended life. |
|||
• Always close the shear valves during |
|||
• Never leave the nozzle unattended while |
|||
maintenance and inspection activities. |
|||
dispensing fuel. |
|||
• Always relieve pressure from system prior |
|||
• Never use sparking or flaming devices within |
|||
to performing maintenance activities. |
|||
20 ft / 6.1 m of dispensers. |
|||
• Always check continuity after installation |
|||
• Never use power tools near dispensers or |
|||
using a megohmeter (Refer to PEI RP 400 |
|||
to aid in the installation process. |
|||
for details). |
|
||
|
• Never use cell phone within 20 ft / 6.1 m of |
||
• Always replace or remove from service |
|||
dispensers. |
|||
damaged or leaking dispensing equipment |
|||
• Never reenter car when fueling vehicle. |
|||
immediately. |
|
||
|
• Never allow gasoline to touch eyes or skin. |
||
• Always report leaks / spills / accidents |
|||
• Never use at flow rates in excess of |
|||
to appropriate authorities. |
|
||
|
regulatory guidelines. |
||
• Always wear appropriate safety equipment |
|||
• Never use at flow rates less than 5 gpm / |
|||
during maintenance activities. |
|||
18.9 Lpm. |
|||
• Always have appropriate fire extinguishing |
|||
• Never dispense flammable material into |
|||
equipment within 5 ft / 1.5 m of dispensers. |
|||
unapproved containers. |
|||
• Always use pipe sealant approved for gasoline |
|||
• Never dispense fuel without a valid |
|||
service. |
|
||
|
driver’s license. |
||
|
|
||
Listings |
(pending) |
|
Important safety instructions - save these instructions in a readily accessible location.
WARRANTY
VAPOR PRODUCTS – Husky Corporation will, at its option, repair, replace, or credit the purchase price of any Husky manufactured product which proves upon examination by Husky, to be defective in material and/or workmanship for a period of one (1) year of installation or fifteen (15) months from the manufacture date of shipment by Husky, whichever occurs first. The warranty period on repaired or replacement vapor recovery products is only for the remainder of the warranty period of the defective product.
CONVENTIONAL PRODUCTS – Husky Corporation will, at its option, repair, replace, or credit the purchase price of any Husky manufactured product which proves upon examination by Husky, to be defective in material and/or workmanship for a period of one (1) year from the manufacture date of shipment by Husky.
Buyer must return the products to Husky, transportation charges prepaid. This Warranty excludes the replaceable bellows, bellows spring assembly, spout assembly and scuff guard, unless (i) damage is obvious when the product is removed from shipping carton and (ii) the defective product is returned to Husky prior to use. This Warranty does not apply to equipment or parts which have been installed improperly, damaged by misuse, improper operation or maintenance, or which are altered or repaired in any way.
The Warranty provisions contained herein apply only to original purchasers who use the equipment for commercial or industrial purposes. There are no other warranties of merchantability, fitness for a particular purpose, or otherwise, and any other such warranties are hereby specifically disclaimed.
Husky assumes no liability for labor charges or other costs incurred by Buyer incidental to the service, adjustment, repair, return, removal or replacement of products. Husky assumes no liability for any incidental, consequential, or other damages under any warranty, express or implied, and all such liability is hereby expressly excluded.
Husky reserves the right to change or improve the design of any Husky fuel dispensing equipment without assuming any obligations to modify any fuel dispensing equipment previously manufactured.
Husky Corporation • 2325 Husky Way • Pacific, MO 63069 • Phone: (800) 325-3558 • Fax: (636) 825-7300 • www.husky.com
Page 2 |
009339-3 02/2013 |