Haier HSU-18LV03, HSU-18LV07, HSU-22LV03 Manual

0 (0)

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-09HV03

HSU-12HV03

HSU-09LV03

HSU-12LV03

HSU-18LV03

HSU-22LV03

Please read this operation manual before using the air conditioner

No.0010561676

Cautions

Disposal of the old air conditioner

Safety Instructions and Warnings

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled

.Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

Disposal of the packaging of your new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts

out and gets into eyes, it may result in serious eye injuries.

1

Cautions

Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1.Applicable ambient temperature range:

Maximum:D.B/W.B 32C/23C

Indoor Minimum:D.B/W.B 18C/14C

Cooling

 

 

 

 

Maximum:D.B/W.B 43 C/26 C

 

Outdoor Maximum:D.B

18 C

 

Indoor

Maximum:D.B

27 C

 

Maximum:D.B

15 C

 

 

Heating

Outdoor Maximum:D.B/W.B 24 C/18 C

Minimum:D.B/W.B -7 C/-8 C

2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V.

4.The wiring method should be in line with the local wiring standard.

5.After installation, the power plug should be easily reached.

6.The waste battery should be disposed properly.

7.The appliance is not intended for use by young children or infirm persons without supervision.

8.Young children should be supervised to ensure that they do not play with the appliance.

9.Please employ the proper power plug, which fit into the power supply cord.

10 .The power plug and connecting cable must have acquired the local attestation.

2

Cautions

Safety Instruction

Please read the following Safety Instructions carefully prior to use.

The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.

Installation

WARNING

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.

lnstallation in a inadequate place may cause accidents. Do not install in the following place.

Connect the earth

Do not install in the

Do not get the unit

cable.

place where there is

exposed to vapor

 

any possibility of

or oil steam.

 

inflammable gas

 

 

leakage around the

 

 

unit.

 

earthing

 

 

 

PROHIBITION

PROHIBITION

Check proper installation of the drainage securely

STRICT

ENFORCEMENT

3

Haier HSU-18LV03, HSU-18LV07, HSU-22LV03 Manual

Cautions

WARNING

When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.

OFF

STRICT

 

ENFORCEMENT

Use an exclusive power source with a circuit breaker

Connect power supply cord

Use the proper voltage

Do not use power supply cord

to the outlet completely

 

extended or connected in halfway

 

 

STRICT

STRICT

PROHIBITION

ENFORCEMENT

ENFORCEMENT

 

Do not use power supply cord

Take care not to damage

Do not insert objects into the air

in a bundle.

the power supply cord.

inlet or outlet.

PROHIBITION

PROHIBITION

PROHIBITION

Do not start or stop the

Do not channel the air flow directly

Do not try to repair or reconstruct

operation by disconnecting

at people, especially at infants or

by yourself.

the power supply cord and so on.

the aged.

 

PROHIBITION

PROHIBITION

 

 

CAUTION

 

Do not use for the purpose of storage of

Take fresh air occasionally especially

Do not operate the switch with

food, art work, precise equipment,

when gas appliance is running at the

wet hand.

breeding, or cultivation.

same time.

 

 

STRICT

PROHIBITION

PROHIBITION

ENFORCEMENT

Do not install the unit near a fireplace

Check good condition of the

Do not pour water onto the unit

or other heating apparatus.

installation stand

for cleaning

 

 

PROHIBITION

PROHIBITION

PROHIBITION

Do not place animals or plants in

Do not place any objects on or

Do not place flower vase or water

the direct path of the air flow

climb on the unit.

containers on the top of the unit.

 

PROHIBITION

PROHIBITION

PROHIBITION

4

Parts and Functions

Indoor unit

Display board

Outlet

Inlet

Air filter(inside)

Air Purifying Filter

 

(inside)

 

Inlet grille

 

 

Anion generator

Vertical flap

(inside)

 

(adjust up and down air flow.

Power plug

Don't adjust it manually)

Horizontal louver

 

(adjust left and right air flow)

 

Outdoor unit

HSU-09LV03

HSU-09HV03

HSU-18LV03

HSU-12LV03

HSU-12HV03

HSU-22LV03

 

 

 

 

1

OUTLET

3

CONNECTING PIPING AND ELECTRICAL WIRING

2

INLET

4

DRAIN HOSE

5

Parts and Functions

 

15

8

 

9

16

 

10

17

11

18

12

19

13

20

 

14

21

TEMP

11. LOCK display

 

 

12. FAN SPEED display

 

LOW

MED

HI

AUTO

13. TIMER ON display

 

14. TEMP button

 

 

Used to select your desired temperature. 15. Operation mode display

1

 

ON

 

22

Operation mode

AUTO COOL DRY HEAT FAN

 

OFF

FAN

SWING

 

 

 

 

 

2

 

 

 

23

Remote controller

 

MODE

HEALTHAIRFLOW SLEEP

24

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

HEALTH

FRESH

 

25

16. Signal sending display

4

 

 

 

 

 

 

31

17. UV light degerming function display

CLOCK

 

 

SET

5

 

 

 

26

18. Left/right air flow display

TIMER

 

 

STERILIZE

6

 

 

 

27

19. TEMP display

 

7

 

 

 

28

Remote controller: to display the TEMP. setting.

 

LIGHT

LOCK

20. TIMER OFF display

RESET CODE

 

30

 

 

 

29

21. CLOCK display

 

 

 

 

 

22. FAN button

 

 

 

 

 

 

 

 

 

 

 

 

Used to select fan speed: LOW,MED, HI, AUTO

 

 

 

 

 

23. ON/OFF button

 

 

 

 

 

 

Used for unit start and stop.

 

 

 

 

 

24. SLEEP button

 

1. SWING button

 

 

 

 

Used to select sleep mode.

 

 

 

 

25. HEALTH AIRFLOW button

Used to select up or down air sending direction.

Used to set the healthy airflow mode.

2. HOUR button

 

 

 

 

 

 

 

 

26. SET button

 

Used to set clock and timer setting.

 

Used to confirm timer and clock settings.

3. MODE button

 

 

 

 

 

 

 

 

27. STERILIZE button

Used to select operation mode. AUTO,

Use to set UV light degerming function

COOL,DRY, FAN,HEAT.

 

 

28. LOCK

 

4. HEALTH button

 

 

 

 

 

 

 

Used to lock buttons and LCD display. If

Used to set healthy operation.

 

 

pressed, the other buttons will be disabled

5. CLOCK button

 

 

 

 

 

 

 

 

and the lock condition display appears.

Used to set correct time.

 

 

Press it once again, lock will be canceled

6. TIMER button

 

 

 

 

 

 

 

 

and lock condition display disappears.

Used to select TIMER ON,

 

 

29. LIGHT button

 

TIMER OFF, TIMER ON-OFF.

 

 

 

Colorful display bar of the controlling indoor

7. RESET

 

 

 

 

 

 

 

 

machine is on and extinguished.

When the remote controller appears

30. CODE

 

abnormal, use a sharp pointed article

 

Used to select CODE A or B with a press,A or

to press this button to reset the

 

 

B will be displayed on LCD.

remote controller normal

 

 

Please select A without special explanation.

8. HEALTH display

 

 

 

 

 

 

31. FRESH button

 

9. SLEEP display

 

 

 

 

 

 

 

 

 

Used to set FRESH AIR operation.

10. SWING UP/DOWN display

 

 

 

 

NOTE: (1)The following functions and related displays are not available ,

, and 31 .

(2) Cooling only unit do not have functions and displays related with heating.

6

Parts and Functions

Clock Set

When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:

1.Press CLOCK button,"AM" or "PM" flashes.

2.Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly.

3.After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.

MODE

HEALTHAIRFLOW SLEEP

HEALTH

FRESH

CLOCK

SET

TIMER

STERILIZE

RESET CODE LIGHT LOCK

Remote controller's operation

When in use, put the signal transmission head directly to the receiver hole on the indoor unit.

The distance between the signal transmission head and the receiver hole should be within 7 m without any obstacle as well.

Don't throw or knock the remoter controller.

When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.

Loading of the battery

Load the batteries as illustrated right 2 R-03 (7#) batteries

Remove the battery cover:

Slightly press" "area and push down the cover as illustrated.

Load the battery:

Be sure that the loading is in line with the "+" / ". request as illustrated on the bottom of the case.

Put on the cover again.

Confirmation indicator:

After pressing power ON/OFF, if no display, reload the batteries.

Note:

Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.

Used two new same-typed batteries when loading.

If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.

Hint:

Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.

7

Loading...
+ 17 hidden pages