GEAppliances.com
<![endif]>Air Conditioners
<![if ! IE]><![endif]>Room
Safety Instructions . . . . . . . . . . . . . 2, 3
Operating Instructions |
|
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . |
4–6 |
Care and Cleaning |
|
Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . |
. . .6 |
Outdoor Coils . . . . . . . . . . . . . . . . . . . . . . |
. . . 6 |
Installation Instructions . . . . . . 7–10
Troubleshooting Tips . . . . . . . . . . . .11
Normal Operating Sounds . . . . . . . . . . . .11
Consumer Support
Consumer Support . . . . . . . . . . Back Cover Ownership Registration for
Customers in Canada only . . . . . . . . 13, 14 Warranty for Customers
in Canada . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Warranty for Customers
in the U.S.A. . . . . . . . . . . . . . . . . . . . . . . . . . .15
*EnErgy Star® labeled product
Owner’s Manual and
Installation Instructions
AEW05
AEW06*
AEW08*
AEZ05
AEZ06*
AEZ08*
Climatiseur
Manuel d’utilisation et instructions d’installation
La section française commence à la page 17
Acondicionador
de aire
Manual del propietario y instrucciones de instalación
La sección en español empieza en la página 33
As an EnErgy Star® partner, GE has determined that this product meets the EnErgy Star® guidelines for energy efficiency.
Write the model and serial numbers here:
Model # _________________________
Serial # __________________________
Find these numbers on a label on the side of the air conditioner.
In Canada, contact us at: |
49-7627 7-10 GE |
|
www.GEAppliances.ca |
||
|
<![endif]>Consumer Support Tips Instructions Care and Cleaning Instructions Safety Instructions
<![if ! IE]><![endif]>Troubleshooting Installation Operating
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.
SAFETY PRECAUTIONS
n Use this appliance only for its intended purpose as described in this Owner’s Manual.
nThis air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
nNever unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
nReplace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
nTurn the unit OFF and unplug your air conditioner before cleaning.
nGE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.
nFor your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
nAll air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.
nIf the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
nThese R410A air conditioning systems require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant.
DO NOT use equipment certified for R22 refrigerant only.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric
shock hazard from this appliance.
|
Power cord includes a current interrupter device. |
|
A test and reset button is provided on the plug |
|
case. The device should be tested on a periodic |
|
basis by first pressing the TEST button and |
|
then the RESET button while plugged into the |
|
outlet. If the TEST button does not trip or if the |
|
RESET button will not stay engaged, discontinue |
|
use of the air conditioner and contact a qualified |
2 |
service technician. |
|
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.
GEAppliances.com
WARNING!
USE OF EXTENSION CORDS—115-Volt models only
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.
However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14-gauge, 3-wire grounding-type appliance extension cord having a grounding-type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the 230/208 volt models.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
3
<![endif]>Installation Cleaning and Care Operating Instructions Safety
<![if ! IE]><![endif]>Instructions Instructions
<![if ! IE]><![endif]>Support Consumer TroubleshootingTips
<![endif]>Safety Instructions
About the controls on the air conditioner.
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Light indicates the unit is in the temperature or
Light indicates the unit delay time Set mode. is in the temperature or
delay time Set mode.
<![endif]>Consumer Support Tips Instructions Care and Cleaning Instructions
<![if ! IE]><![endif]>Troubleshooting Installation Operating
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
(on some models) |
Light indicates the |
|
|
|||
|
|
|
|
|
|||
|
|
|
delay timer is set. |
|
|
||
NOTE: The display always shows the |
Light indicates the |
|
|||||
room temperature except when setting |
|
||||||
delay timer is set. |
|
||||||
(on some models) |
|||||||
the Set temperature or the Delay timer. |
|||||||
|
|||||||
|
|
Air Conditioner Controls
Delay 1–24hr |
|
|
|
Delay timer |
|
|
Delay timer |
Decrease |
|
|
Increase |
Mode select |
|
|
Auto Fan on |
Fan speed |
|
|
Fan speed |
Fan |
Fan |
Increase |
|
Decrease |
|
|
Unit power |
Temperature |
|
|
|
|
|
on/off |
|
set Increase |
|
|
|
and |
|
|
|
Decrease |
|
|
|
|
|
|
|
Remote Control
Controls
Power Pad
Turns air conditioner on and off. When turned on, the display will show the room temperature.
Display
Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.
NOTE: The display will change to show the room temperature after settings have been made.
To recall the Set temperature, press the Temp Increase ▲or Decrease ▼pads.
Temp Increase ▲/Decrease ▼Pads
Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.
Delay Timer Increase ▲(+) /Decrease ▼(–)
Pads
Each touch of the Increase ▲/ Decrease▼ pads on the unit or the Increase + / Decrease – pads on the remote control will set the delay time when using the Delay 1–24hr timer ( ). The Set light will turn on while setting.
Fan Speed Pads
Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease – pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.
4
Mode Pad
Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.
Delay Pads
Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.
Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or the pad on the remote control. Each touch of the Increase ▲ / Decrease ▼pads on the unit or the Increase + / Decrease – pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or the pad on the remote control. Use the Increase ▲/ Decrease▼ pads on the unit or the Increase + / Decrease – pads on the remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.
GEAppliances.com
Do Not Operate in Freezing Outdoor |
freezing outdoor conditions. |
Conditions |
|
This cool-only air conditioner was not designed for |
|
freezing outdoor conditions. It must not be used in |
|
Remote Control
nTo ensure proper operation, aim the remote control at the signal receiver on the air conditioner.
nThe remote control signal has a range of up to 20 feet.
nMake sure nothing is between the air conditioner and the remote control that could block the signal.
nMake sure batteries are fresh and installed correctly as indicated on the remote control.
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase ▲ / Decrease ▼pads to set the desired temperature between 64°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off
to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select theCool mode and
High or Med fan with a middle set temperature.
For Maximum Cooling—Select theCool mode and High fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the
Cool mode and Low fan with a middle set temperature.
Energy Saver Mode
|
|
Controls the fan. |
|
ON—The fan will cycle on and off with the |
OFF—The fan runs all the time, while the compressor |
compressor. This results in wider variations of room |
cycles on and off. |
temperature and humidity. Normally used when the |
|
room is unoccupied. NOTE: The fan may continue to |
|
run for a short time after the compressor cycles off. |
|
|
|
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan |
NOTE: Auto Fan Speed cannot be used when in the |
speed to provide air circulation and filtering without |
Fan Only Mode. |
cooling. Since fan-only settings do not provide |
|
cooling, a Set temperature cannot be entered. The |
|
room temperature will appear |
|
in the display. |
|
Auto Fan Speed
Set to Auto fan speed for the fan speed to |
NOTE: Auto Fan Speed cannot be used when in the |
automatically set to the speed needed to provide |
Fan Only Mode. |
optimum comfort settings with the set temperature. |
|
If the room needs more cooling, the fan speed |
|
will automatically increase. If the room needs less |
|
cooling, the fan speed will automatically decrease. |
|
Power Outage Recovery Feature
In the case of a power outage or interruption, the |
feature was set, it will resume countdown. You may |
|
unit will automatically restart in the settings last |
need to set a new time if desired. |
5 |
used after the power is restored. If the Delay 1–24hr |
|
|
<![endif]>Installation Cleaning and Care Operating Instructions Safety
<![if ! IE]><![endif]>Instructions Instructions
<![if ! IE]><![endif]>Support Consumer TroubleshootingTips
<![endif]>Consumer Support Tips Instructions Care and Cleaning Instructions Safety Instructions
<![if ! IE]><![endif]>Troubleshooting Installation Operating
About the controls on the air conditioner.
Additional important information.
Air Direction
Use the lever to adjust the air direction left and right only.
Care and cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug from |
To clean, use water and a mild detergent. Do not use |
the wall outlet before cleaning. |
bleach or abrasives. |
Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
To remove:
Pull the tab on the right side of the unit until the filter is out.
To remove:
Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
CAUTION:DO NOT operate the air |
Tab |
Tab |
conditioner without a filter because dirt and lint will |
|
|
clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.
How to Insert the Batteries in the Remote Control
1
2
3
6
Remove the battery cover by sliding it according to the arrow direction.
Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.
Reattach the cover by sliding it back into position.
NOTES:
nUse 2 “AAA” (1.5 volt) alkaline batteries. Do not use rechargeable batteries.
nRemove the batteries from the remote control if the system is not going to be used for a long time.
Installation |
Air Conditioner |
Instructions |
|
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT — Save these instructions
for local inspector’s use.
• IMPORTANT — Observe all governing codes and ordinances.
•Note to Installer – Be sure to leave these instructions with the Consumer.
•Note to Consumer – Keep these instructions for future reference.
•Skill level – Installation of this appliance requires basic mechanical skills.
•Completion time – Approximately 1 hour
•We recommend that two people install this product.
•Proper installation is the responsibility of the installer.
•Product failure due to improper installation is not covered under the Warranty.
•You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
ELECTRICAL REQUIREMENTS
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
|
|
|
Pencil |
Ruler or tape measure |
|
|
|
|
Some models require a 115/120-volt AC,
60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the Level Scissors or knife
possibility of electric shock hazard. If the wall outlet |
|
||||||||||
you plan to use is only a 2-prong outlet, it is your |
|
||||||||||
responsibility to have it replaced with a properly |
Power cord includes a current interrupter |
||||||||||
grounded 3-prong wall outlet. |
|||||||||||
device. A test and reset button is provided on the |
|||||||||||
|
|
|
|
|
|
|
|
|
Some models require 230/208-volt AC, |
||
|
|
|
|
|
|
|
|
|
plug case. The device should be tested on a periodic |
||
|
|
|
|
|
|
|
|
|
protected with a time-delay fuse or circuit |
basis by first pressing the TEST button and then the |
|
|
|
|
|
|
|
|
|
|
breaker. These models should be installed |
||
|
|
|
|
|
|
|
|
|
RESET button while plugged into the outlet. If the |
||
|
|
|
|
|
|
|
|
|
on their own single branch circuit for best |
||
|
|
|
|
|
|
|
|
|
TEST button does not trip or |
||
|
|
|
|
|
|
|
|
|
performance and to prevent overloading |
||
|
|
|
|
|
|
|
|
|
if the RESET button will not stay engaged, discontinue |
||
|
|
|
|
|
|
|
|
|
house or apartment wiring circuits, which |
||
|
|
|
|
|
|
|
|
|
use of the air conditioner and contact a qualified |
||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
could cause a possible fire hazard from |
||
|
|
|
|
|
|
|
|
|
service technician. |
||
|
|
|
|
|
|
|
|
|
overheating wires. |
||
|
|
|
|
|
|
|
|
|
7 |
||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
PARTS INCLUDED
(Appearance may vary)
Top mounting rail
Air conditioner
Installation Instructions
Window sash seal
Foam top window gasket
Right accordion
panel
Left accordion panel
Top mounting rail seal strip
Type A (4) |
Type B (6) |
Window locking |
|
|
bracket (1) |
8
Installation Instructions
1WINDOW REQUIREMENTS
•These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
•The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
•All supporting parts must be secured to firm wood, masonry or metal.
•The electrical outlet must be within reach of the power cord.
•Follow the dimensions in the table and illustration for your model.
Models |
A |
B |
AEW05, AEZ05 |
12 1/2″ min. |
23″–38″ |
AEW06, AEW08 |
13 11/32″ min. |
21″–38 1/8″ |
AEZ06, AEZ08 |
|
|
A
B
(With accordion panels)
2 STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly.
To adjust for this, attach a piece of wood to the sill.
WOOD PIECES WIDTH: 2″
LENGTH: Long enough to fit inside the window frame.
THICKNESS: To determine the thickness, place a piece of wood on the sill to make it 1/2″ higher than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1/2″ higher |
||||
|
|
|
|
|
than vinyl frame |
|
|||
|
|
|
|
|
(on some windows) |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wood |
|
|
1/2″ higher |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
than storm |
|
|
|
|
|
|
|
|
|
window |
|
|
|
|
Sill |
|||
|
frame |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
Storm window |
|
|
|
|
|
|
|
||
|
|
|
Vinyl frame |
|
|
|
|||
frame |
|
|
|
|
|||||
|
|
|
|
|
|
|
3ATTACH THE TOP MOUNTING RAIL SEAL STRIP
(Some models may have the seal strip already attached to the top mounting rail. If applicable, skip this step.)
Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top mounting rail, along the front edge.
Top mounting rail
Remove backing from seal strip
FRONT VIEW |
Top mounting rail |
Seal strip
4 PREPARE THE AIR CONDITIONER
AInstall the top mounting rail with 4 Type A screws from the outside of the case.
Top mounting rail
Bottom mounting rail
BHold the accordion panel in one hand and gently pull back to free the open end.
9
Installation Instructions
4PREPARE THE AIR CONDITIONER (cont.)
CSlide the free end of the accordion panel into the side panel rails. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
NOTE: There is a right and a left accordion panel. Be sure to use the proper panel for each side.
DSlide the left and right accordion panels into the top and bottom mounting rails.
Top left |
Top mounting rail |
Top right |
|
|
Bottom mounting rail
5 PREPARE THE WINDOW
Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.
6INSTALL THE AIR CONDITIONER IN THE WINDOW
APlace the air conditioner on the sill with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.
|
|
|
|
|
or |
or |
|
|
|
|
Type B screws
BExtend the left and right accordion panels to the vertical window sashes and attach, through the holes in the panels, with 5 Type B screws, as appropriate.
7INSTALL SUPPORT BRACKET AND FOAM TOP WINDOW GASKET
|
|
|
|
|
|
|
|
|
CAUTION: |
|
|
|
|
A |
|
|
|
|
||
|
|
|
|
|
||
|
|
To prevent broken |
Vinyl |
|
|
|
|
|
glass or damage to |
|
|
|
|
|
|
windows, on vinyl or other |
|
|
|
|
|
|
similarly constructed |
|
|
|
|
|
|
windows, attach the |
|
|
|
|
|
|
window locking bracket to |
|
|
|
|
|
|
the window side jamb with |
|
Wood |
|
|
|
|
one Type B screw. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BCut the foam top window gasket to the window width.
|
Stuff the foam |
C |
|
|
between the glass |
|
and the window |
|
to prevent air and |
|
insects from getting |
|
into the room. |
|
NOTE: If the gasket supplied does not fit your |
|
window, obtain appropriate material locally to |
|
provide a proper installation seal. |
10
Troubleshooting Tips. |
GEAppliances.com |
|
Problem |
Possible Causes |
What To Do |
|
The air conditioner |
•Make sure the air conditioner plug is pushed |
Air conditioner |
||
does not start |
is unplugged. |
completely into the outlet. |
|
The fuse is blown/circuit |
•Check the house fuse/circuit breaker box and replace |
|
breaker is tripped. |
the fuse or reset the breaker. |
|
Power failure. |
•The unit will automatically restart in the settings last |
|
|
used after the power is restored. |
|
|
•There is a protective time delay (approximately |
|
|
3 minutes) to prevent tripping of the compressor |
|
|
overload. For this reason, the unit may not start |
|
|
normal cooling for 3 minutes after it is turned |
|
|
back on. |
|
The current interrupter |
•Press the RESET button located on the power cord plug. |
|
device is tripped. |
•If the RESET button will not stay engaged, discontinue |
|
|
use of the air conditioner and contact a qualified |
|
|
service technician. |
Air conditioner does |
Airflow is restricted. |
•Make sure there are no curtains, blinds or furniture |
not cool as it should |
|
blocking the front of the air conditioner. |
|
The temp control may |
•On models with touch pads: In the Cool mode, press the |
|
not be set correctly. |
Decrease ▼pad. |
|
|
•On models with control knobs, turn the temperature |
|
|
knob to a higher number. |
|
The air filter is dirty. |
•Clean the filter at least every 30 days. |
|
|
See the Care and Cleaning section. |
|
The room may have been hot. |
•When the air conditioner is first turned on, you need |
|
|
to allow time for the room to cool down. |
|
Cold air is escaping. |
•Check for open furnace registers and cold air returns. |
|
Cooling coils have iced up. |
•See “Air conditioner freezing up” below. |
Air conditioner |
Ice blocks the air flow |
•On models with control knobs, set the mode control at |
freezing up |
and stops the air conditioner |
High Fan or High Cool with the Temp at 1 or 2. |
|
from cooling the room. |
•On models with touch pads, set the controls atHigh Fan |
|
|
or High Cool and set the thermostat to a higher |
|
|
temperature. |
The remote control |
The batteries are inserted |
•Check the position of the batteries. They should be |
is not working |
incorrectly. |
inserted in the opposite (+) and (–) direction. |
|
The batteries may be dead. |
•Replace the batteries. |
Water drips outside |
Hot, humid weather. |
•This is normal. |
Water drips indoors |
The air conditioner is not |
•For proper water disposal, make sure the air conditioner |
|
tilted to the outside. |
slants slightly from the case front to the rear. |
Water collects in |
Moisture removed from air |
•This is normal for a short period in areas with little |
base pan |
and drains into base pan. |
humidity; normal for a longer period in very humid areas. |
|
|
|
<![endif]>Installation Cleaning and Care Operating Instructions Safety
<![if ! IE]><![endif]>Instructions Instructions
<![if ! IE]><![endif]>Troubleshooting
<![if ! IE]><![endif]>Tips
Normal Operating Sounds
nYou may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
nYou may hear the thermostat click when the compressor cycles on and off.
nWater will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
nThe fan may run even when the compressor does not.
11 |
<![if ! IE]> <![endif]>Support Consumer |
Consumer Support |
Troubleshooting |
Installation |
Care and Cleaning |
Operating |
Safety Instructions |
|
Tips |
Instructions |
Instructions |
||||
|
|
|
||||
<![if ! IE]> <![endif]>12 |
|
|
|
|
<![if ! IE]> <![endif]>.Notes |
Please place in envelope and mail to:
Veuillez mettre dans une enveloppe et envoyez à :
OWNERSHIP REGISTRATION
P.O. BOX 1780
MISSISSAUGA, ONTARIO
L4Y 4G1
(FOR CANADIAN CONSUMERS ONLY)
13
14
GE Air Conditioner—One Year Limited Warranty.(For customers in the U.S.A.)
Staple your receipt here.
Proof of the original purchase date is needed to make a warranty claim.
For The Period Of: |
|
We Will Replace: |
|
|
Replacement unit for any product which fails due to a defect in materials or workmanship. |
One Year |
|
|
From the date of the |
|
The replacement unit is warranted for the remainder of your product’s original one-year |
original purchase |
|
warranty period. The replacement unit may either be a new unit or a refurbished unit. |
In Order to Make a Warranty Claim During the First 30 Days from the Date of Original Purchase:
nProperly pack your unit. We recommend using |
nInclude in the package a copy of the sales receipt or |
the original carton and packing materials. |
other evidence of date of original purchase. Also print |
nReturn the product to the retail location where |
your name and address and a description of the defect. |
it was purchased. |
|
In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:
nLocate your original sales receipt and make a note of your model and serial number.
nCall GE at 1.866.907.1655 to initiate the product replacement process.
nYou will be asked to provide your name, address, date of purchase, model and serial number.
nGE will arrange for a carton to be sent to your home to recover the product.
nYou must return the product (postage pre-paid by GE) to GE’s recovery center before a replacement unit will be provided. Please include a description of the defect.
nYou should receive your replacement product within 7 to 10 business days after your unit is received.
nIf you experience any problems or delays after initiating the replacement process, please call 1.256.796.6610 for assistance.
What Is Not Covered:
nCustomer instruction. This owner’s manual provides information regarding operating instructions and user controls.
nImproper installation. If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer.
You are responsible for providing adequate electrical connecting facilities.
nFailure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
nReplacement of house fuses or resetting of circuit breakers.
nFailure due to corrosion on models not corrosionprotected.
nDamage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
nIncidental or consequential damage caused by possible defects with this air conditioner.
nDamage caused after delivery.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product replacement as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether express, oral or statutory which extend beyond the description on the face hereof, including specifically the implied warranties of merchantability or fitness for a particular purpose.
Warrantor: General Electric Company. Louisville, KY 40225 |
15 |
<![endif]>Installation Cleaning and Care Operating Instructions Safety
<![if ! IE]><![endif]>Instructions Instructions
<![if ! IE]><![endif]>Support Consumer TroubleshootingTips