INSTALLATION INSTRUCTIONS
FRONT CONTROL FREESTANDING ELECTRIC RANGE
INSTALLATION AND SERVICE MUST BE
PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
|
|
|
FOR YOUR SAFETY: Do not store or use gasoline |
United States |
|
|
|
|
|
or other |
flammable vapors and liquids in the vicinity of this or |
|
|
any other appliance. |
|
|
|
|
|
IMPORTANT SAFETY INSTRUCTIONS
Iftheinformationinthismanualisnotfollowed exactly,afireorelectricalshockmayresultcausingproperty damage, personal injury or death.
Important Notes to the Installer:
•Read all instructions contained in these installation instructions before installing range.
•Remove all packing material from the oven compartments before connecting the gas & electrical supply to the range.
•Observe all governing codes and ordinances.
•Be sure to leave these instructions with the consumer.
Important Notes to the Consumer:
Keep these instructions with your owner’s guide for future reference.
•As when using any appliance generating heat, there are certain safety precautions you should follow.
These are listed in the Use & Care Guide, read it carefully.
•Be sure your range is installed and grounded properly by a qualified installer or service technician.
•Make sure the wall coverings around the range can withstand the heat generated by the range.
•To eliminate the need to reach over the surface elements, cabinet storage space above the elements should be avoided.
Tip Over Hazard
• A child or adult can tip the range and be killed.
• Verify the anti-tip device has been installed to floor or wall.
•Ensure the anti-tip device is re-engaged to floor or wall when the range is moved.
•Do not operate the range without the anti-tip device in place and engaged.
•Failure to follow these instructions can result in death or serious burns to children and adults.
Range
leveling leg
Anti-tip bracket
To check if the anti-tip bracket is installed properly, use both arms to grasp the rear edge of the range back. Carefully attempt to tilt range forward. When properly installed, the range should not tilt forward.
Refer to the anti-tip bracket installation instructions supplied with your range for proper installation.
P/N 809127105 (1901) Rev. C
English – pages 1-8
Spanish - pages 9-16
1
30” ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
1.Clearances and Dimensions
a.Provide adequate clearances between the range and adjacent combustible surfaces.
b.Location—Check location where the range will be installed. Check for proper electrical supply and the stability of floor.
c.Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid and level.
Front |
Typical cabinet installation |
Side |
|
|
|
|
||||
view |
|
|
|
|
|
view |
|
|
|
|
|
|
|
|
|
|
|
|
29 7/8" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
30” |
|
|
|
|
|
|
|
|
|
|
Minimum |
|
|
|
|
|
|
|
Minimum to |
1” |
30” Minimum* |
|
Minimum to |
|
13” |
|
|
|
|
wall on either |
|
18” |
|
|
|
|
|
|||
|
cabinets on |
Maximum depth |
|
|
|
|||||
side of range |
|
|
36 5/8" |
|
|
|||||
above 36” height. |
|
|
either side |
for cabinets |
|
|
|
|||
|
|
of range |
above range top. |
± 1/4" |
|
|
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
25” Max. |
Maximum |
|
||
|
|
|
|
|
|
|
|
|
||
36” |
|
|
|
|
|
|
|
|
|
|
|
|
|
30” |
0” clearance below cooking top and at rear of range |
|
26 6/8" |
|
|||
Fig. 1 |
|
|
Minimum |
|
|
|
||||
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
Door |
47" |
|
|
|
|
|
|
|
|
Fig. 2 |
open |
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE |
|
|
|
BACK |
||||||
TOP OF THE COOKING SURFACE AND THE BOTTOM |
|
|
|
VIEW |
||||||
OFAN UNPROTECTED WOOD OR METAL CABINET; OR |
|
|
|
|
||||||
24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR |
|
|
All dimensions for electrical outlet location |
|||||||
METAL CABINET IS PROTECTED BY NOT LESS THAN |
|
|
are maximum. |
|||||||
|
|
|
|
|||||||
1/4" (6 mm) FLAME RETARDANTMILLBOARD COVERED |
|
|
|
|
||||||
WITHNOTLESSTHANNO.28MSGSHEETSTEEL,0.015" |
|
|
Dashed cubed area |
|||||||
|
|
|
|
|
|
|
|
|
||
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm)ALUMINUM |
|
|
shows where the electrical outlet must be |
|||||||
|
|
installed |
||||||||
OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS |
|
|
for flush to the wall installation. |
|||||||
|
|
|
|
|||||||
THEMINIMUMFORTHEREAROFTHERANGE.FOLLOW |
|
11” |
|
|
||||||
ALL DIMENSION REQUIREMENTS PROVIDED ABOVE |
|
|
|
|||||||
|
(279 mm) |
|
|
|||||||
TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE |
|
22” |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
HAZARD,ANDINCORRECTCOUNTERTOPANDCABINET |
|
(559 mm) |
|
|
||||||
|
|
|
|
|||||||
CUTS. |
|
|
|
|
|
|
|
|
|
|
|
|
6” |
TO ELIMINATE THE RISK OF BURNS OR FIRE BY |
|
(152 mm) |
|
Wall |
|
REACHING OVER HEATED SURFACE UNITS, CABINET |
|
|
STORAGESPACELOCATEDABOVETHESURFACEUNITS |
|
Edge |
2-5/8” (67 mm) for models |
|
|
SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE |
equipped with warmer drawers |
|
PROVIDED,THERISKCANBEREDUCEDBYINSTALLING |
3-1/2” (89 mm) for models |
|
equipped with storage drawers |
Fig. 3 |
|
A RANGE HOOD THAT PROJECTS HORIZONTALLY A |
|
|
|
|
|
MINIMUM OF 5" (127 mm) BEYOND THE BOTTOM OF |
|
|
|
|
|
THE CABINETS. |
|
|
2
30” ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
2.Tools You Will Need
For leveling legs and Anti-Tip Bracket:
• Adjustable wrench or channel lock pliers
• 5/16" Nutdriver or Flat Head
Screwdriver
• Electric Drill & 1/8" Diameter Drill Bit (Masonry Drill Bit if
installing in concrete)
• Level & Measuring Tape For electrical supply connection:
• 1/4" & 3/8" Socket driver or Nutdriver Additional Materials You Will Need:
• Power Supply Cord or
• Copper Electrical Wiring & Metal Conduit (for hard wiring)
3.Anti-Tip Bracket Installation
Instructions
Important Safety Warning
To reduce the risk of tipping of the range, the range should be secured to the floor by properly installed anti-tip bracket and screws packed with the range. Failure to install the anti-tip bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it. Serious injury might result from spilled hot liquids or from the range itself.
If range is ever moved to a different location, the anti-tip brackets must also be moved and installed with the range.
Instructions are provided for installation in wood or cement fastened to either the floor or wall. When installed to the wall, make sure that screws completely penetrate dry wall and are secured in wood or metal. When fastening to the floor or wall, be sure that screws do not penetrate electrical wiring or plumbing.
A.LocatetheBracketUsingtheTemplate-(Bracketmaybe located on either the left or right side of the range. Use the information below to locate the bracket if template is not available). Mark the floor or wall where left or right sideoftherangewillbelocated. Ifrearofrangeisagainst thewallornofurtherthan1-1/4"(32mm)fromwallwhen installed, you may use the wall or floor mount method. If molding is installed and does not allow the bracket to fit flush against the wall, remove molding or mount bracket tothefloor.Forwallmount,locatethebracketbyplacing the back edge of the template against the rear wall and thesideedgeoftemplateonthemarkmadereferencing the side of the range. Place bracket on top of template and mark location of the screw holes in wall.
If rear of range is further than 1-1/4" (32 mm) from the wall when installed, attach bracket to the floor. For floor mount, locate the bracket by placing back edge of the template where the rear of the range will be located. Markthelocationofthescrewholes,shownintemplate.
Fig. 4
B.Drill Pilot Holes and Fasten Bracket - Drill a 1/8” (3 mm) pilotholewherescrewsaretobelocated. Ifbracketisto be mounted to the wall, drill pilot hole at an approximate 20° downward angle. If bracket is to be mounted to masonry or ceramic floors, drill a 5/32” (4 mm) pilot hole 1-3/4”(44mm)deep.Thescrewsprovidedmaybeused in wood or concrete material. Use a 5/16” (8 mm) nutdriver or flat head screwdriver to secure the bracket in place.
(32 mm)
Fig. 5
(32 mm)
Fig. 6
3
30” ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
C.Level and Position Range - Level range by adjusting the
(4)levelinglegswithawrench.Note:Aminimumclearance of 1/8” (3 mm) is required between the bottom of the range and the leveling leg to allow room for the bracket. Useaspiritleveltocheckyouradjustments. Sliderange back into position. Visually check that rear leveling leg is inserted into and fully secured by theAnti-Tip Bracket by removing lower panel or storage drawer. For models with a warmer drawer or broiler compartment, grasp the top rear edge of the range and carefully attempt to tilt it forward.
(17 mm)
Fig. 7
4.Electrical Connection
Requirements
Avoid fire hazard or electrical shock. Failure tofollowthiswarningmaycasueseriousinjury,fire,ordeath.
This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI/NFPA No. 70 -- latest edition -- and Local Electrical Code requirements.
This appliance may be connected by means of “permanent wiring” or power supply cord kit.”
When installing permanent wiring, do not leave excess wire in range compartment. Excess wire in the range compartment may not allow the rear access cover to be replaced properly and could create a potential electrical hazard if wires become pinched. Connect only as instructed under “Permanent Wire Connections” in Step 5c. When using flexible conduit or range cable use flex connector or range cable strain relief
Models requiring power supply cord kit
RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF AN INCORRECT SIZE RANGE CORD KIT IS USED, THE INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED OR STRAIN RELIEF BRACKET IS DISCARDED.
This appliance may be connected by means of a power supply cord. Only a power supply cord kit rated at 125/250 volts minimum, and marked for use with ranges shall be used. See Fig. 10 for cord kit ampere rating information. Cord must have either three (3) or four (4) conductors (See Fig. 8). Terminals on end of wires must be either closed loop or open-end spade lugs with upturned ends. Cord must have strain relief properly installed. See Steps 5a. for 4-Wire or 4b. for 3-Wire connections.
5. Electrical Connection to the
Range
The Rear Access Cover must be removed (Fig 9). To remove, loosen center screw (one screw) and remove cover. The terminal block will then be accessible.
3 & 4 - Wire electrical wall Receptacle types & recommended mounting orientation on wall
Required for new and remodeled installations
4-Wire Wall receptacle (14-50R)
Allowed for existing installations
3 Wire Wall receptacle (10-50R)
Fig. 8
NOTE: Range is shipped from factory with 1-3/8" dia. hole as shown. To use either 7/8" dia. hole or 1-1/8" dia. knockouts refer to Fig. 9.
Rear
Access
Cover
Fig. 9
4
30” ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
Fig. 10 |
NOTE: Internal white wire not present on all models.
Fig. 12
Fig. 11
5A. POWER CORD CONNECTIONS
(4-Wire Connection Instructions - Refer to Fig.12)
Before wiring the range review the suggested power source location drawing in Fig. 3. If connecting to a 4-Wire electrical system (new branch-circuit or mobile home requires 4-Wire connection):
1.Follow the manufacturer’s installation instructions supplied with the strain relief and install (Also see Figs. 9, 10 & 11).
2.Insert the end connectors for Line 1, Line 2 and Neutral and tighten securely to the terminal block. IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block. Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed.
3.You must disconnect the ground strap. Remove the factory installed ground screw & plate to release the copper ground strap from the frame of the appliance. Cut and discard the copper ground strap & plate.
KEEP the ground screw.
4.Connect the ground wire (Green) lead with the eyelet to the frame of the appliance with the ground screw using the same hole in the frame where the ground screw was originally installed (See Fig. 12).
5.Make sure all screws are tightened securely and replace the rear access cover (See Fig. 9).
5B. POWER CORD CONNECTIONS
(3-Wire Connection Instructions
For existing installations ONLY - Refer to Fig. 13).
1.Follow the manufacturer’s installation instructions supplied with the strain relief and install (Also see Figs. 9, 10 & 11).
2.Insert the end connectors for Line 1, Line 2 and Neutral and tighten securely to the terminal block (See Fig. 13).
IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block. Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed.
3.Make sure all connections are tightened securely and replace the rear access cover (See Fig. 9).
NOTE: Internal white wire not present on all
models.
Fig. 13
5