Frigidaire FFFH20F3VW, FFFU20F2VW Wiring Diagram

4.8 (5)
Frigidaire FFFH20F3VW, FFFU20F2VW Wiring Diagram

IMPORTANT SAFETY NOTE

The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.

IMPORTANT

If any green/yellow grounding wires are removed during servicing, theymustbereturnedtotheiroriginalpositionandproperlysecured.

PERFORMANCE

Ambient Temperature

70ºF

90ºF

Operating Time

100%

100%

Freezer Temperature

4 to -4ºF

4 to -4ºF

Low Side Pressure (cut-in)

-

-

Low Side Pressure (cut-off)

-7.02 to -3.94

-6.63 to -4.65

PSIG

PSIG

 

High Side Pressure

35 to 37 PSIG

51 to 56 PSIG

Wattage

32W

46.6W

Amps

0.4

0.61

Base Voltage

115V

115V

Refrigerant Charge

50g

50g

SERVICE DATA SHEET

A14365701

AUTOMATIC DEFROST UPRIGHT

FREEZER - R600a

DEFROST CONTROL

The defrost period will vary dependent on the heater on time, with a maximum of 60 minutes. There is a 7 minute idle (drip time) time after the heater turns off before the evaporator fan and compressor will turn on. During the defrosting period a temperature sensor monitors the evaporator temperature and the main control board turns the defrost heater off after the frost on the evaporator has melted.

IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

Specifications subject to change without notice. For complete performance data by model, refer to service manual. Options shown are not necessarily part of the model.

SERVICE MODE DIAGNOSTIC TESTS

Allows technicians to step through available tests to diagnose individual electrical circuits.

NOTE: There is a magnetic switch located in the bottom front of the cabinet (beside the green power on indicator light) and a permanent magnet is located in a holder in the bottom of the door that work together to sense when the door is opened and closed.

To Enter

• Open the door.

Service Mode:

• Using a permanent magnet, activate the magnetic

 

switch 4 times within 2 seconds, holding the forth

 

activation against the magnetic switch until a long beep

 

is heard and the interior AC LED Light bulb turns on.

 

• Move the magnet away from the magnetic switch.

 

The internal light will turn off indicating the unit is in

 

service mode.

 

NOTE: When service mode is entered, the green

 

power on indicator light will remain on.

 

• Using the permanent magnet, activate the magnetic

 

switch 2 times to terminate the current test and

 

activate the next test. Two beeps will sound confirming

 

the service mode has advanced to the next test.

 

• Test 1: Compressor and condenser fan:

 

The compressor and condenser fan turns ON as

 

soon as service mode is activated.

 

• Test 2: Defrost heater

 

NOTE: The defrost heater has a thermal fuse on

 

each side of the heater element. During the defrost

 

heater test the main board monitors the evapora-

 

tor temperature and will automatically turn off

 

the defrost heater, if the evaporator temperature

 

exceeds a specified value to ensure the thermal

 

fuses are not permanently open circuited as they

 

are designed to operate.

 

• Test 3: AC LED bulb

 

CAUTION: DO NOT REPLACE THE AC LED BULB

 

WITH ANY BULB GREATER THAN 5 WATTS.

 

• Test 4: Evaporator Fan

To manually exit

• Using a permanent magnet, activate the magnetic

service mode:

switch 4 times in 2 seconds, holding the forth activa-

 

tion against the magnetic switch until a long beep is

 

heard and the interior AC LED Light bulb turns on. The

 

unit will restart in normal operating mode.

 

• Unplug the unit from power and plug it back in to

 

power. The unit will restart in normal operating mode.

 

• The unit will automatically exit service mode if no

 

magnetic switch activation is detected after 10 min-

 

utes. The unit will restart in normal operating mode.

To activate

• Using a permanent magnet, activate the magnetic switch

manual defrost:

5 times in 2 seconds, holding the fifth activation against

 

the magnetic switch until five short beeps are heard.

 

• The unit can enter in manual defrost only during

 

normal operating mode.

 

• The unit will not enter in manual defrost if already

 

in defrost mode.

 

• The unit will not enter manual defrost if the tem-

 

perature control knob is in the OFF position.

 

• The defrost heater has a thermal fuse on each side of

 

the heater element. During manual defrost, the main

 

board monitors the evaporator temperature and will

 

automatically turn off the defrost heater if the evapo-

 

rator temperature exceeds a specified value to ensure

 

the thermal fuses are not permanently open circuited

 

as they are designed to operate.

Loading...
+ 1 hidden pages