Flowserve Worcester 14, Worcester 13 User Manual

Copyright
All rights reserved. No part of these instructions may be reproduced, stored in a retrieval system or transmitted in any form or by any means without prior permission of Flowserve Flow Control.
Initial Release, 01-APR-2018
These instructions must be read prior to installing, operating, and
maintaining this equipment.
Worcester 13 / 14 Series
Installation
Operation
Maintenance
Small three-piece multiway ball valves
WCENIM0002-01
Original Instructions
Worcester 13 / 14 Series User Instruction WCENIM0002-01
Page 1 of 13
CONTENTS
1 General Information ................................................................................................................ 2
1.1 Scope of manual ......................................................................................................................................... 2
1.2 Disclaimer ...................................................................................................................................................... 2
2 Health and Safety .................................................................................................................... 3
3 Product Information ................................................................................................................. 4
3.1 Certification .................................................................................................................................................. 4
3.2 Design ............................................................................................................................................................ 5
4 Storage ..................................................................................................................................... 5
5 Installation ................................................................................................................................ 6
5.1 Preparation ................................................................................................................................................... 6
5.2 Installation ..................................................................................................................................................... 6
6 Operation ................................................................................................................................. 7
6.1 Use .................................................................................................................................................................. 7
6.2 Manual operation ....................................................................................................................................... 7
6.3 Remote operation ....................................................................................................................................... 7
7 Maintenance ........................................................................................................................... 8
7.1 General.......................................................................................................................................................... 8
7.2 In-line leakage ............................................................................................................................................. 8
7.3 Stem leakage ............................................................................................................................................... 8
7.4 Body/Connector leakage ......................................................................................................................... 8
8 Repair Kits ................................................................................................................................. 8
9 Refurbishment .......................................................................................................................... 9
9.1 Disassembly ................................................................................................................................................... 9
9.2 Reassembly ................................................................................................................................................... 9
10 Technical Data....................................................................................................................... 11
10.1 Gland nut torque ....................................................................................................................................... 11
10.2 Stem assembly torque .............................................................................................................................. 11
10.3 Connector bolt torque ............................................................................................................................. 11
10.4 Torque data ................................................................................................................................................ 11
11 Valve Exploded View Diagram ............................................................................................ 12
These instructions must be read prior to installing, operating, and maintaining
this equipment.
Worcester 13 / 14 Series User Instruction WCENIM0002-01
Page 2 of 13
1 General Information
These instructions must be read prior to installing, operating, and maintaining
this equipment.
These instructions must be read prior to installing, operating, using, or maintaining the
equipment in any region worldwide. The equipment must not be put into service until all of the safe operating conditions noted in the instructions have been met. Failure to comply with
the information provided in the User Instructions is considered to be misuse. Personal injury, product damage, delay in operation, or product failure caused by misuse are not covered by the Flowserve warranty.
1.1 Scope of manual
These instructions must be kept close to the product’s operating location or directly with the product.
These instructions must be read prior to installing, operating, using, or maintaining the equipment in any region worldwide. The equipment must not be put into service until all of the safe operating conditions noted in the instructions have been met. Failure to comply with the information provided in the User Instructions is considered to be misuse. Personal injury, product damage, delay in operation, or product failure caused by misuse are not covered by the Flowserve warranty.
This document covers the Worcester 13 / 14 series: Pressure rating – Variable Size range – DN 15 – 50, NPS ½ - 2
1.2 Disclaimer
Information in this User Instruction is believed to be complete and reliable. In spite of
all Flowserve’s efforts to provide comprehensive information and instructions, sound
engineering and safety practices should always be used. Please consult with a qualified engineer.
Flowserve manufactures products to applicable International Quality Management System Standards as certified and audited by external Quality Assurance organizations. Genuine parts and accessories have been designed, tested, and incorporated into the products to help ensure continued product quality and performance in use. As Flowserve cannot test parts and accessories sourced from other vendors the incorrect incorporation of such parts and accessories may adversely affect the performance and safety features of the product. The failure to properly select, install, or use authorized Flowserve parts and accessories is considered to be misuse. Damage or failure caused by misuse is not covered by
Flowserve’s warranty. In addition, any modification of Flowserve products or removal
of original components may impair the safety of these products in use.
Worcester 13 / 14 Series User Instruction WCENIM0002-01
Page 3 of 13
2 Health and Safety
The product/system must not be operated beyond the parameters specified for the application. If there is any doubt as to the suitability of the product/system for the application intended, contact Flowserve for advice, quoting the serial number.
When installing, operating or maintaining valves:
a) Complete a risk assessment and eliminate or reduce hazards to an acceptable
level.
b) Work in accordance with safe systems of work. c) Observe all site health and safety rules. d) Wear all the necessary personal protective equipment (PPE). e) Never remove or maintain a valve or joint unless the line has been fully de-
pressurised, drained, and where necessary, purged of toxic / explosive / flammable media. Always operate the valve to the open position to ensure that no trapped pressure exists within the cavity.
f) Never handle valves that have been used on harmful substances unless they
have been completely decontaminated and certified safe to handle.
g) Never use a valve on an application which exceeds its prescribed operating
parameters. Refer to Flowserve Flow Control technical sales for performance curves for further information.
h) Never modify or alter valves unless the manufacturer has been consulted or
recommends such changes.
i) Wrenches are only designed to operate the valves and must not be used to
carry them as it may result in operator injury or damage to the valve stem and sealing.
j) Use appropriate lifting methods and equipment when installing, maintaining and
removing the product. Ensure that the valve is correctly supported in its operating location.
k) The valve must be installed in a system design to prevent excessive forces on the
flanges and connectors.
l) Consult Flowserve Flow Control technical sales before equipment is installed in
areas subject to seismic activity or extreme climates.
m) The valve should be protected by other devices to prevent over-pressurisation,
e.g. increased pressure caused by external fire.
n) It is the end user’s responsibility to ensure compatibility of the media with the
materials of construction of the product. The integrity of the valve may be affected by the effects of corrosion and erosion.
o) If the processes or environments that the valve is used in are likely to cause
temperatures (high or low) that may cause injury to personnel if touched, adequate protection must be fitted on the valve.
p) If the valve is to be used for unstable gas applications, ensure that the
operational parameters as indicated on the product identification plate cannot be exceeded.
Worcester 13 / 14 Series User Instruction WCENIM0002-01
Page 4 of 13
3 Product Information
3.1 Certification
This product is compliant with the following EU regulations:
a) Pressure Equipment Directive (PED) 2014/68/EU: If the ID plate carries the CE
mark, PED number ‘2014/68/EU’, and the notified body identity number ‘0086’,
the product complies with the PED. If these numbers are not present, the product is classified under Sound Engineering Practice (SEP) and may only be used within the limitations defined in tables 6, 7, 8 and 9 of the PED.
b) Explosive Atmospheres (ATEX) 2014/34/EU: If the ID plate carries the CE mark,
ATEX number ‘2014/34/EU’, the explosion protection symbol, and ATEX codes
identifying the equipment, the product complies with the ATEX directive.
Figure 1 Valve ID plate markings (DN 32 and above)
Figure 2 Valve ID plate markings (DN 25 and below)
Loading...