FANUC 30i-B, 31i-B, 32i-B31i-B Parametr Manual

ADDITIONAL INFORMATION
FANUC Series 30i –MODEL B FANUC Series 31i –MODEL B FANUC Series 32i –MODEL B
1. Type of applied technical documents
Name
FANUC Series 30i –MODEL B FANUC Series 31i –MODEL B FANUC Series 32i –MODEL B PARAMETER MANUAL
PARAMETER MANUAL
Spec.No./Version
2. Summary of change
Group Name / Outline New,
Basic
Function
The parameter of deleting a folder recursively is added.
Sections 4.133 are modified about Network functions.
The parameter concerned to Power consumption monitoring
screen was added.
The parameter that enables the softkey display of 8.4” screen up to
B-64490EN/01
Add,
Correct,
Delete
Add
Correct
Add
Applicable
Date
Immediately
ED
Date
Date
12 characters was added.
The parameter of Spindle synchronous control for spindle control
with Servo motor is added.
The parameter of USB Memory is added.
Spindle speed command clamp function is added
Title
Draw No.
Design
2010.06.18
Design
Description Page
Add
Add
Add
Add
FANUC Series 30i / 31i / 32i-MODEL B
PARAMETER MANUAL

B-64490EN/01-01

1/2
Optional
Function
Sections 4.7, 4.67, 4.103 are modified and section 4.9 is added
about Network functions.
The description of the designation of servo axes for spindle use is
added.
Parameter about 5-axis machining configuration selecting function
is newly added.
Parameter about Stored Pitch Error Compensation function is newly
added.
Parameter of safety function by FL-net is added.
Parameter about Three-dimensional Rotary Error Compensation is
newly added.
Add
Correct
Add
New
New
Add
New
Immediately
Parameter about High-speed Smooth TCP is added and corrected.
Unit
Maintenance
parts
Notice - This function is available in the following software.
G301,G311,G321,G331, G401,G411,G421,G431,G501 : 01.0 or later
Correction
Another
Add
Correct
ED
Date
Date
Design
2010.06.18
Design
Title
Draw No.
Description Page
FANUC Series 30i / 31i / 32i-MODEL B
PARAMETER MANUAL
B-64490EN/01-01
2/2
Add the following description to 4.100 PARAMETERS OF DISPLAY AND EDIT (4 OF 5)
#7 #6 #5 #4 #3 #2 #1 #0
11364 FDR
[Input type] Parameter input [Data type] Bit
#3 FDR When the folder that includes programs or folders are tried to be deleted,
0: the folder is not deleted. 1: the folder, and the program and the folders in it are deleted.
ED
Date
Date
Design
2010.06.17
Design
Title
Draw No.
Description Page
FANUC Series 30i / 31i / 32i-MODEL B
Deleting a folder recursively
B-64490EN/01-01
1/1
Replace NC parameters No.905 and 906 to the following explanation in 4.7 PARAMETERS OF
ETHERNET/DATA SERVER FUNCTIONS.
#7 #6 #5 #4 #3 #2 #1 #0
0905 UNS DSF PCH DNE
[Input type] Parameter input [Data type] Bit
#0 DNE During DNC operation using the FOCAS2/Ethernet functions, the termination of DNC
operation is: 0: Waited. 1: Not waited. (FOCAS2/HSSB compatible specification)
#1 PCH At the start of communication of the Data Server function, FTP file transfer function, or
machine remote diagnosis function, checking for the presence of the server using PING is: 0: Performed. 1: Not performed.
NOTE
Usually, set 0.
If 1 is set not to check the presence of the server by using PING, it may take several tens of seconds to recognize an error when the server is not present in the network. For mainly security reasons, a personal computer may be set so that it does not respond to the PING command. To communicate with such a personal computer, set 1.
#3 DSF When an NC program is stored on the memory card of the Data Server:
0: The file name takes priority. 1: The program name in the NC program takes priority.
NOTE
Only when the file of the personal computer side is registered to
the memory card of the data server by operating the CNC side, this parameter becomes effective.
#4 UNS In the CNC Unsolicited Messaging function, when the end of the function is requested by other
than the CNC Unsolicited Messaging server currently connected: 0: The request for the end of the function is rejected. 1: The request for the end of the function is accepted.
#7 #6 #5 #4 #3 #2 #1 #0
0906 SCM OVW
[Input type] Parameter input [Data type] Bit
ED
Date
Date
Design
2010.06.17
Design
Title
Draw No.
Description Page
FANUC Series 30i / 31i / 32i-MODEL B
Network functions
B-64490EN/01-01
1/5
#2 OVW When the Data Server is working as an FTP server, if it receives a file having the same name as
for an existing file in it from an FTP client: 0: An error occurs. 1: No error occurs, and the received file is written over the existing file.
NOTE
The data server Explorer connection function option is necessary to
use this parameter.
#5 SCM Data Server function accesses its memory card with the forwarding mode:
0: A memory card-supported mode recognized by Data Server. 1: A traditional PIO mode2.
NOTE
When this parameter is set, the power must be turned off before
operation is continued.
ED
Date
Date
Design
2010.06.17
Design
Title
Draw No.
Description Page
FANUC Series 30i / 31i / 32i-MODEL B
Network functions
B-64490EN/01-01
2/5
Add the following explanation 4.9 PARAMETERS OF ETHERNET/FL-net FUNCTIONS.

4.9 PARAMETERS OF ETHERNET/FL-net FUNCTIONS

0970 Select hardware that operates Ethernet or Data Server function
0971 Select hardware that operates first FL-net function
0972 Select hardware that operates second FL-net function
[Input type] Parameter input [Data type] Byte [Valid data range] -1 to 6
Hardware that operates each function is selected.
Value Hardware
-1 Not used 0 Unsetting (NOTE 1) 1 Multi-function Ethernet (NOTE 2) 2 (reserved) 3 Fast Ethernet board mounted in slot 1 4 Fast Ethernet board mounted in slot 2 5 Fast Ethernet board mounted in slot 3 6 Fast Ethernet board mounted in slot 4
NOTE
1 When one hardware option is mounted and the software option is
uniquely decided, the function can run even if NC parameters No.970-971 are set to 0.
2 The Data Server function cannot be used on Multi-function
Ethernet. If using the Data Server function, don’t set 1 to NC parameter No.970.
3 When the Ethernet function and the FL-net function are specified,
the two functions can be operated as FL-net/Ethernet coexisting function by setting the same hardware as NC parameters No.970 and 971. The each function can be operated separately by setting the different hardware as NC parameter No.970 and 971. Refer to FL-net board CONNECTION MANUAL (B-64163EN) about FL-net/Ethernet coexisting function.
4 When the Ethernet function and the Data Server function are
specified, the two functions are operated on the hardware set by NC parameters No.970. The each function cannot be operated separately on the different hardware.
ED
Date
Date
Design
2010.06.17
Design
Title
Draw No.
Description Page
FANUC Series 30i / 31i / 32i-MODEL B
Network functions
B-64490EN/01-01
3/5
NOTE
5 When the Ethernet function, the Data Server function, and the
FL-net function are specified, please specify different hardware for parameter No.970 and 971. In this case, the Ethernet function and the FL-net function cannot be operated on the same hardware.
ED
Date
Date
Design
2010.06.17
Design
Title
Draw No.
Description Page
FANUC Series 30i / 31i / 32i-MODEL B
Network functions
B-64490EN/01-01
4/5
Loading...