ColorSource SpotPhotometry Guide

 

ColorSource Series

Throw Distance Multiplier (TDM)

To determine the distance from the center of the beam (Origin) to a certain illuminance level at a particular distance, multiply the desired throw distance by the TDM desired on the Iso-Illuminance diagram.

Throw Distance (TD) x Throw Distance Multiplier (TDM) = Distance from the Origin (DfO) (distance from the center of the beam) Example: 25 feet (TD) x 0.047 (TDM) = 1.175 feet from center of beam (DfO)

Iso-Illuminance Diagram

(Flat Surface Distribution)

10%

50%

% illuminance foot candle or lux

2

ETC®

ColorSource SpotPhotometry Guide

 

ColorSource Series

T A B L E O F C O N T E N T S

COLORSOURCE SPOT

5° . . . . . . . . . . . . . . . . . . . . . . . . . 4

10° . . . . . . . . . . . . . . . . . . . . . . .

.

4

14° . . . . . . . . . . . . . . . . . . . . . . .

.

5

19° EDLT . . . . . . . . . . . . . . . . . . . . .

.

5

26° EDLT . . . . . . . . . . . . . . . . . . . . .

.

6

36° EDLT . . . . . . . . . . . . . . . . . . . . .

.

6

50° LT . . . . . . . . . . . . . . . . . . . . . .

.

7

70° . . . . . . . . . . . . . . . . . . . . . . .

.

7

90° . . . . . . . . . . . . . . . . . . . . . . .

.

8

15-30° Zoom Narrow . . . . . . . . . . . . . . . .

.

8

15-30° Zoom Mid . . . . . . . . . . . . . . . . . .

 

. 9

15-30° Zoom Wide . . . . . . . . . . . . . . . . .

.

9

25-50° Zoom Narrow . . . . . . . . . . . . . . . .

. 10

25-50° Zoom Mid . . . . . . . . . . . . . . . . . .

 

10

25-50° Zoom Wide . . . . . . . . . . . . . . . . . . 11

COLORSOURCE SPOT WITH FRESNEL ADAPTER

 

 

ColorSource Spot with Fresnel adapter - Spot . . . . . . .

. 12

ColorSource Spot with Fresnel adapter - Mid . . . . . . . . . . . . . . .

.

12

ColorSource Spot with Fresnel adapter - Flood . . . . . . .

 

13

3

ETC®

ColorSource SpotPhotometry Guide

ColorSource Spot 5°

Mode

Degree

Candela

Field

Beam

Power

Efficacy

 

 

 

Lumens

Lumens

Consumption

(lpw)

 

 

 

 

 

 

 

Maximum Output

397,563

3,979

3,765

160

24.9

 

 

 

 

 

 

 

At 3200K

358,269

3,609

3,428

115

31.4

 

 

 

 

 

 

 

At 5600K

373,500

3,752

3,577

141

26.6

 

 

 

 

 

 

 

Metric conversions: For meters, multiply feet by 0.3048 For lux, multiply footcandles by 10.76

7.0˚

7.4˚

Beam Angle

 

Field Angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Throw Distance (d)

10’

15’

20’

30’

611.9’

 

3.0m

4.6m

6.1m

9.1m

186.5m

 

 

 

 

 

 

Field Diameter

1.3’

1.9’

2.6’

3.9’

– 

 

0.4m

0.6m

0.8m

1.2m

 

 

 

 

 

 

 

 

Illuminance (fc)

3,744

1,664

936

416.0

1

 

 

 

 

 

 

Illuminance (lux)

40,302

17,912

10,075

4,478

10.76

 

 

 

 

 

 

For field diameter at any distance, multiply distance by 0.129

For beam diameter at any distance, multiply by 0.122

ColorSource Series

Candela Plot

400000

350000

300000

250000

 

 

 

 

Candela150000

 

 

 

X

200000

 

 

 

Y

 

 

 

 

100000

 

 

 

 

50000

 

 

 

 

0

 

 

 

 

-5

-2.5

0

2.5

5

Degrees

Iso-Illuminance Diagram

(Flat Surface Distribution)

10% 50%

% illuminance foot candle or lux

ColorSource Spot 10°

Mode

Degree

Candela

Field

Beam

Power

Efficacy

 

 

 

Lumens

Lumens

Consumption

(lpw)

 

 

 

 

 

 

 

Maximum Output

10°

242,720

4,985

4,582

160

31.2

 

 

 

 

 

 

 

Regulated 3200K

10°

218,731

4,522

4,172

115

39.3

 

 

 

 

 

 

 

Regulated 5600K

10°

228,029

4,700

4,354

141

33.3

 

 

 

 

 

 

 

Metric Conversions: For meters, multiply feet by 0.3048 For lux, multiply footcandles by 10.76

10.7˚

11.2˚

Beam Angle

 

Field Angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Throw Distance (d)

10’

15’

20’

30’

492.7’

 

3.0m

4.6m

6.1m

9.1m

150.2m

 

 

 

 

 

 

Field Diameter

2.0’

2.9’

3.9’

5.9’

– 

 

0.6m

0.9m

1.2m

1.8m

 

 

 

 

 

 

 

 

Illuminance (fc)

2,427

1,079

607

269.7

1

 

 

 

 

 

 

Illuminance (lux)

26,126

11,612

6,532

2,903

10.76

 

 

 

 

 

 

For field diameter at any distance, multiply distance by 0.196

For beam diameter at any distance, multiply by 0.187

Candela Plot

250000

200000

150000

 

 

 

 

 

 

Candela

 

 

 

 

 

X

 

 

 

 

 

 

Y

100000

 

 

 

 

 

 

50000

 

 

 

 

 

 

0

 

 

 

 

 

 

-7.5

-5

-2.5

0

2.5

5

7.5

Degrees

Iso-Illuminance Diagram

(Flat Surface Distribution)

10%

50%

% illuminance foot candle or lux

4