Instructional Manual Continuous Ink System for use in Epson WF 600/WF610/NX515/NX510
he ink tank has two chambers per color, the front chamber is to hold the ink and the rear chamber is to control the
NOTE: The following instructions and pictures are for reference only. Besides removing the cartridge
carrier cover, you do not need to alter your printer in any other way such as cutting or drilling any
parts of the printer.
Before using this product, please read and follow the instructions. After opening your package, make sure to check that all
the accessories shown in figures 1-1 through 1-3 below.
Conduct Parts Check:
1. Accessories
a. Continuous Ink System (1) b. Air breather plugs (4) & Syringe (1) &Screwdriver (1)
c. T shape Adhesive Pad (1) & square adhesive pad (2)
Fig. 1-1 Fig. 1-2 Fig.1-3
2. Set-Up Continuous Ink System (CIS)
a. Before installation, lay out all your parts in front of your printer.
b. Check your system for any leakage, and make sure your tubing system is tightly connected and straight.
c. T
flowing pressure. It is important that the rear chamber contains only a small amount of ink (as little as possible). The ink
should reside in the front chamber. To remove any excess ink from the rear chamber you need to first make sure the ink tank
plugs are tightly closed, then tilt the ink tank forward to make the majority of the ink flow into the front chamber. (Fig. 2-1
through Fig. 2-3)
Fig.2-1 Fig.2-2 Fig.2-3
d. Place the CIS on the right hand side of the printer as shown (Fig.2-4), and keep it at the same level as the printer.
e. Hold down the ink tank with one hand and unplug the original air stoppers as shown (Fig.2-5), make sure to save
these for later use.
f. Install the Air Breather wider end into the ink reservoir tank, making a snug fit (Fig.2-6).
Caution: Make sure not to push the breathers too tight as it could crack the tank. Also when removing the air breathers
from the tank use caution to avoid cracking.
Fig.2-4 Fig.2-5 Fig.2-6

3. Cartridge Installation
Turn on your printer and push the ink, cartridge replacement button and the cartridge carrier should move into the
a.
replacement position. Once the carrier is in place unplug the printer from the wall. Gently move the cartridge carrier back
and forth right to left in the printer assuring that it moves smoothly.
b. Use the screwdriver to remove the cartridge carrier cover. (Fig 3-1)
c. Place one of the square adhesive pads on the tubing as shown in (Fig. 3-2)
d. Then move the cartridge compartment to the left side of the printer (Fig.3-3)..
Fig.3-1 Fig.3-2 Fig.3-3
Fig.3-4 Fig.3-5
e. Then slide cartridges under the plastic bracket as shown in (Fig. 3-4).
f. Slide cartridge compartment to the right, insert cartridges and place the square adhesive pad on the side of the cartridge
compartment as shown (Fig. 3-5).
4. Tube Adjustment and Positioning
a. Place the T shape adhesive pads as shown (Fig 4-1).
b. Place the second square adhesive on the outside of the printer as shown (fig.4-2).
c. Adjust tubing between cartridge compartment and tube guide to correct length; allowing enough room for the
cartridge to move back and forth freely. Make sure the tubes are not twisted and are straight (Fig.4-3).
Fig4-1 Fig4-2 Fig4-3
d. Turn on the printer and make sure the system moves smoothly.
5. Refilling Ink
When the ink levels reach the indicator margin (sticker on the ink tank with red line Fig 5-1) the ink tank system
has reached its low level line and needs to be refilled.
Follow these steps:
1. Gently remove the air breather plugs in order to have more filling room.
2. Remove plugs off of the filling hole and refill the proper color of ink into the corresponding ink tank (Fig 5-2),
(use towel to wipe off any spillage).
3. Make sure you use the specially designed inks Low Foam Ink for the CI System as they are specifically designed