Advanced Modular Calibration and HART
Communication System
Combines an advanced multi-function calibrator and HART communicator
with world-class pressure measurement and generation.
Modularity brings a whole
new perspective to multi-function
test instruments, -calibrators and
HART communicators
System features
• Modular concept provides greater fl exibility
• Re-range during use
• Expand over time
• Adapt by application
• Allows signifi cant inventory reductions
• Simplifi es user training
• Reduces cost of ownership
• A Complete HART communicator and
multifunction calibrator in one device
The system includes:
A combined Multifunction calibrator…
• Accuracy from 0.0025%rdg + 0.002%FS
• Measure, source and simulate mA, mV, V, ohms,
frequency, RTDs and thermocouples
• Easy to use with photo quality touch screen
• Robust, weatherproof and extremely compact
…and a HART digital communicator…
• Device Description Library for HART devices
• Free of charge upgrades and new device
descriptions
• Integral 24V loop power supply to energise HART
devices and loops
• Menu selectable 250 ohm loop resistor
• Measures mA and sources the primary variable for
device trims and calibration
…with advanced connectivity and
documenting features
• PDA version with Windows CE – view loop diagrams,
datasheets, safety procedures, spreadsheets and
create text documents.
• IEEE 802.11g wireless connection with Internet access
Pressure measurement modules
• 25 mbar to 1000 bar (10 inH2O to 15000 psi)
• Accuracy from 0.005%FS
• Fully interchangeable modules with no need for
set-up, calibration or tools
Pressure generation stations
• Advanced pressure generation
- 95% vacuum to 20 bar pneumatic
- 95% vacuum to 100 bar pneumatic
- 0 to 1000 bar hydraulic
• Stand-alone pressure stations can replace hand
pumps and can be used as comparators
Applications
• Instrumentation installation, commissioning,
maintenance and calibration
• HART test, confi guration and calibration
• System measurement and monitoring
• Indicator, recorder and controller testing
• Process loop set up and diagnostics
• Switch, trip and safety system testing
For …
• Plant and process engineers
• Service companies and site contractors
• Installation and commissioning engineers
• Laboratory technicians
• Automate calibration procedures and document
As Found and As Left results
• Store a complete plant database including tags,
devices and procedures
• Graphical views of data log fi les, calibration
results and historical trends
2
A fl exible modular system
The DPI 620 Series - Advanced Modular Calibration and HART Communication
System uses three basic components to provide the multi-functionality to
perform duties formerly requiring a wide range of diff erent instruments.
Features
• Multi-function capabilities: electrical,
frequency, temperature and pressure
• Complete HART communicator included
• Modular re-rangeable and expandable
concept
• Individual components can be used as
stand-alone instruments
• Allows signifi cant inventory reductions
• Simplifi es training and improves
operator safety
• Reduces cost of ownership
Its basic component is an ultra-compact,
electrical, frequency and temperature
calibrator and HART communicator, which
provides simultaneous measurement and
source capabilities with a fully featured
HART digital interface.
Pressure measurement is provided by
interchangeable pressure modules that
can be attached to the calibrator by a
pressure module carrier.
If pressure generation is required the
calibrator and pressure module can
be attached to one of three pressure
generation stations, to form a
fully-integrated pressure calibrator,
of unparalleled performance.
The simple yet sophisticated design and
concept combines, for the fi rst time,
an advanced electrical calibrator with
state-of-the-art pressure measurement
and generation, so that there is no longer
any need to compromise one measurand
capability in favour of another.
Measure and source mA, mV, V, ohms, frequency, RTD’s
and thermocouples.
Re-rangeable pressure measurement and generation from 25 mbar (10 inH2O) to 1000 bar (15000 psi)
Re-rangeable dual channel pressure measurement
from 25 mbar (10 inH
O) to 1000 bar (15000 psi)
2
3
The DPI 620 Series Advanced Modular
Calibrator and HART
Communicator
Features
• Measure, source and simulate multiple parameters
• Complete HART communicator included
• Easy-to-use, with photo quality colour touch screen, which can
be operated by a gloved hand
• Weather-proof to IP 65
• Can display up to 6 active readings
• Available with a range of add-on modules, pressure
measurement modules and generation stations, Intecal Field
Calibration documenting module, 300Vac measurement probe
• Digital interface for pressure modules and future options
• USB master and slave for connecting to a PC and peripherals
• Available in Windows CE version
• Long-life Lithium-Polymer battery pack
The high resolution, colour touch screen of the calibrator shows
only those buttons necessary for the immediate, selected tasks.
The buttons have been sized so that they can be operated by a
gloved hand, with no need for a stylus. The display can be
confi gured to show up to six reading windows and can show
electrical and temperature inputs and outputs, two pressure
module readings, an IDOS pressure measurement, and a
USB-connected device, as well as a HART summary window or full
HART communicator with active mA measurement and actual
primary variable readings.
A Compact and Powerful Electrical Calibrator and
HART Communicator
The DPI 620 electrical calibrator can measure and source mA, mV,
V, Ohms, frequency and a variety of RTDs and T/Cs. It provides an
isolated 24 V loop power supply to energise devices and control
loops and a stabilized dc voltage supply for ratio metric
transducers.
The reading windows also act as active keys and, when pressed,
they expand to show more detailed information or to provide
advance functions such as step and ramp outputs. Colour is used
to emphasize important information, for example, red for critical
or failed values and green for pass or within tolerance.
The DPI 620 includes
comprehensive documenting
features for automating
instrument calibration when
used in conjunction with
Intecal Calibration
Management software.
The compact and lightweight
calibrator is designed for
rugged fi eld application, with
a robust casing and
weather-proofi ng to IP 65. It
features a high-speed digital
interface for connecting to
pressure modules and
pressure generating stations.
This interface will also allow
expansion to meet future
requirements when new
modules and stations become available. It also features USB
connectivity and a microSD card slot with 2 Gb of memory
installed as standard.
4
High performance HART communicator
The DPI 620 multifunction calibrator now incorporates a fully
featured HART
communicators in functionality, ease of use and upgrade support
such that a single hand held device can now confi gure the full
range of HART devices and perform mA trims and sensor
calibrations without the need for secondary equipment such as
ammeters, calibrators, power supplies and loop resistors. This can
signifi cantly reduce equipment inventory, cost of ownership and
greatly simplify maintenance activities The DPI 620 contains the
latest application software and a complete library of registered
HART device descriptions. Upgrades can be simply downloaded
free of charge from our website.
®
communicator which surpasses market leading
The DPI 620 CE Advanced
Modular Calibrator and
HART Communicator
A Multifunction Electrical Calibrator and HART
Communicator with Windows CE
The Windows CE-driven version of the electrical calibrator
provides all the computing power of a conventional hand-held PC
or PDA. It provides standard Windows fi le management and
off ers popular Windows features to allow users to create text
documents and view common fi le types including Excel, Power
Point, Word, pdf and images. This means that operators can
consult user manuals, training presentations, data sheets,
installation drawings etc while in the fi eld or on the plant.
5
The DPI 620 CE with WiFi
Advanced Modular
Calibrator and HART
Communicator
A wirless IEEE 802.11g enabled Multifunction
Electrical Calibrator and HART Communicator
The DPI 620 CE version can be further enhance with wireless IEEE
802.11g communications. For the fi rst time, in a calibrator of this
type, it is possible to link to the Internet and remote networks in
order to access information and to transfer data. This powerful
feature will benefi t service technicians who spend extended
periods away from head offi ce and for those who need instant
access to data, safety information, system drawings, product
datasheets etc., while on the move. It will also provide an
interface to future system modules when a physical connection is
a hindrance.
Technical Specifi cations
General Specifi cations
DisplaySize: 110 mm (4.3 in) diagonal; 480 x 272 pixels
LanguagesEnglish {Default}
Operating temperature -10° to 50°C (14° to 122°F)
Storage temperature-20° to 70°C (-4° to 158°F)
Ingress ProtectionIP65 (Dust-tight, jets of water)
Humidity0 to 90% RH Non condensing
Shock / VibrationBS EN 61010:2001; Def Stan 66-31, 8.4 cat III, 1 m Drop Tested
EMCElectromagnetic compatibility: BS EN 61326-1:2006
Electrical safety Electrical – BS EN 61010 : 2001
Pressure safetyPressure Equipment Directive - Class: Sound Engineering Practice (SEP)
ApprovedCE Marked
Size (L: W: H) DPI 620 only: 183 x114 x 42 mm (7.2 x 4.5 x 1.7 in) + MC 620: ≈ 265 x 114 x 64 mm ( 10.4 x 4.5 x 2.5 in)
Weight DPI 620 only: ≈ 575 g (1.3 lb) – battery included. MC 620 only: ≈ 640 g (1.4 lb). PM 620 only: ≈ 100 g (0.2 lb).
Power supply
Duration Measure functions (CH1): ≈ 12 hours continuous. Dual Function, mA measure (CH2): ≈ 7 hours (24 V Source at 12 mA)
LCD: Colour display with touch-screen
+ PM 620: ≈ 265 x 114 x 93 mm (10.4 x 4.5 x 3.7 in)
Lithium-Polymer battery (GE Part number : IO620-Battery); Capacity: 5040 mAh (minimum), 5280 mAh (typical); Nominal voltage:
3.7 V.
Charge temperature: 0° to 40°C (32° to 104°F) Discharge temperature: -20° to 60°C (-4° to 140°F).
Note: For best battery performance, keep the temperature less than 60°C (140°F). Charge/discharge cycles: > 500 > 70% capacity.