During the summer, optimum comfort is achieved with a temperature of between 24 and 27˚C
and about 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located. One advantage
of portable air conditioning units over fitted models is that they can be moved from one room to another in the home or even transferred between different buildings.
The hot air in your room is passed through a coil cooled by refrigerant gas, losing excess heat and moisture before being discharged again into the room. In single unit models (Pinguino), a small part of this air is used to cool the refrigerant gas befo­re, hot and moist air is being discharged outside. In suitcase models, the cir­cuit is cooled using the air outside.
Each Pinguino and Super­Pinguino can also be used as a fan only.
ECO by Pinguino is the latest generation of ecolo­gical air conditioners. Pin­guino does not contain gases dangerous to the earth's ozone layer (CFC/HCFC). In addition, thanks to the extreme efficiency of the appliance, not only does it save you money on your electric bills, but it saves the environment by not negatively contributing to the greenhouse effect."
For more details, contact or visit our Internet site
www.delonghi.com
What is Pinguino Pinguino and SuperPinguino
GB 3-02-2003 17:10 Pagina 14
15
ENGLISH
Important Safe-guards
• This appliance has been manufactured to cool and de-humidify domestic environments and should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in conformity with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorised Repair Service Centre. Unauthorised servicing can be dangerous.
• In the case that the power cable becomes damaged, this must be substituted only by specialised personnel authorised by the manufacturer.
• This appliance is to be used by adults only; keep children away from it.
• Always ground the appliance. Have the electrical system checked by a qualified electrician.
•Avoid using extension leads with the unit.
• Before cleaning or maintenance operations, always unplug the unit from the socket.
• Do not pull on or place strain on the power cable when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur , or near heat sources.
• If the appliance is utilised in areas where there is no ventilation of air, it is necessary to take precautions to avoid that the refrigerant gases that may leak from the appliance do not remain in the room, thereby causing a fire hazard.
• This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres or greater.
• After turning off the conditioner, always wait at least three minutes before turning it on again.
• Do not rest hot or heavy objects onto the appliance.
• Clean the anti-bacterial filters at least once a week.
•Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie horizontally. Before transporting the unit drain the condensation collecting-tray and tank. Avoid transportation, wait at least 1 hour before switching on the unit.
• The packaging materials can be recycled. You are therefore recommended to place them in the special con­tainers for differentiated waste collection.
• Do not cover this appliance with bags when is not in use.
•Unventilated area where the appilance using flammable refrigerants is installed shall be so constructed that any leaked refrigerants will not stagnate so as to cause a fire or an explosion hazard caussed by igniting stagnant refri­gerants from other source such as electric heater, stove and similar home applications.
• The refrigerant used in this appliance would cause damage to the ozone layer if relased into the atmosphere. The­refore at the end of the working life of the appliance the unit should be taken to a recycling centre for disposal of the refrigerant.
• Keep the unit at least 50 cm away from inflammable substances (alcohol etc) or pressurised containers (eg. aerosol cans).
• The appliance must be used only as indicated in this manual. These instructions are not intended to cover as many as possible conditions and situations which may arise. As with all household appliances installation, operation and conservation should be carried out prudently and following common sense.
DESCRIPTION 1 Air delivery grille 2 Control panel 3 Wheels 4 Handles 5 Housing for hose 6 Cord winder 7 Air intake grill 8 Condensation tank 9 Drainage tube 10 Plug 11 Function selector 12 Air conditioning led 12 Air conditioning/dehumidifying led (mod.
F130eco)
13 Ventilation led 14 Full tank light 15 Thermostat knob 16 Flange 17 Air exhaust hose 18 Window attachment 19 Suckers 20 Blocking device
GB 3-02-2003 17:10 Pagina 15
16
The following instructions will help you set up your air conditioning unit as efficiently as possible.
The appliance must always be installed for use taking care that there are no obstacles blocking the ventilation and exhaust fans.
AIR CONDITIONING WITHOUT INSTALLATION FOR INSTANT TEMPORARY USAGE
With just a few simple operations, Pinguino will restore comfortable conditions in your room:
• Fix the air outlet hose n to the coupling on the back of the unit as shown in figu-
re A.
5
17
•With a double casement window, use the suckersWith a double casement window, use the suckers pro vided to hold the two halves of the window together (fig.
C).
19
• Fix the window attachment to the end of the hose .
• Place the unit near a window or a French window.
• Open the window or French window sligh­tly and place the window attachment as shown in figure B.
18
17
18
A
Setting up
B
C