CITIZEN SR-270X User Manual

Page 1
General Guide .................................................3
Before Starting Calculation ............................4
Basic Calculations ........................................ 10
Scientific Function Calculations .................. 11
Turning on or off.............................................3
Auto power-off function .................................3
Reset operation ..............................................3
Contrast adjustment....................................... 3
Display readout ..............................................4
Using " MODE " keys......................................4
Using " SET UP " keys....................................5
Using Math Mode............................................ 5
Using " 2nd " " ALPHA " Keys ........................6
Making corrections during Input.................... 6
Error Position Display Function.....................6
Replay function ..............................................6
Memory calculation ........................................ 7
Order of operations ........................................7
Accuracy and Capacity...................................8
Error conditions .............................................9
Arithmetic calculation .................................. 10
Parentheses calculations............................. 10
Percentage calculation................................. 11
Display notations.......................................... 11
Answer Function .......................................... 11
Logarithmic and Exponential functions....... 12
Fraction calculation......................................12
Angle unit conversions ................................ 12
Sexagesimal ↔ Decimal transformation...... 13
Trigonometric / Inverse-Tri. functions.......... 13
Hyperbolic / Inverse-Hyp. functions.............13
Coordinates transformation ......................... 13
E – 1
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 2
Statistical Calculations .................................14
Function Table...............................................17
Probability ....................................................13
Other functions ( √, 3, X, x-1, x2,
x3, xy , Abs, RND ) .........................................14
Multi-statement Function .............................14
To Enter data for statistical analysis............15
To analyze data you have entered ................ 15
To view or change data ................................ 17
E – 2
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 3
General Guide
Turning on or off
To turn the calculator on, press [ ON ]; To turn the calculator off, press [ 2nd ] [ OFF ].
Battery replacement
SR-270X is a dual power system which is powered by one button-type battery (G13 or L1154) and a solar cell. If the display becomes dim and difficult to read, the batteries should be replaced as soon as possible.
To replace batteries:
1) Remove the screw and the battery compartment cover.
2) Remove the old battery and insert a new one with polarity in correct directions, then replace the cover.
3) After changing battery, please use a pointed object to press the reset hole in the rating label area located at the rear of this unit.
Auto power-off function
This calculator automatically turns off when not operated for approximately 3~9 minutes. It can be reactivated by pressing [ ON ] key and the memory, settings are retained.
Reset operation
If the calculator is on but you get unexpected results, press [ 2nd ] [ CLR ] in sequence. A message appears on the display to confirm whether you want to reset the calculator and clear memory contents after selecting [ 3 ].
Clear? 1: Se tup 2:M em ory 3: A ll
[ 3 ]
Re set A ll? [ = ] : Yes [AC ] : C ancel
To clear all variables, pending operations, statistical data, answers, all previous entries, and memory, please press [ = ]; To cancel the reset operation without clearing the calculator, please press [ AC ].
If the calculator is lock and further key operations becomes impossible, please use a pointed object to press the reset hole at the same time to release the condition. It will return all settings to default settings.
Contrast adjustment
Pressing the [ W ] or [ X ] following [ 2nd ] [ SET UP ] [ T ] [ 5 ] (WCONTX) keys in sequence can make the contrast of the screen lighter or darker. Holding either key down will make the display become respectively lighter or darker. After finishing your setting, press [ AC ] to exit.
E – 3
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 4
Display readout
The display comprises the entry line, the result line, and indicators.
D
Math
Entry line
12369x7532x1032
c
9. 3163308
SR-270X displays an entry of up to 99 digits. Entries
Entry line
Result line
Indicators
Indicator Meaning
2nd 2nd set of function keys are active
A Alphabetic keys are active
M There is a number in the memory STO Storing variable mode is active RCL Recalling variable mode is active STAT Statistics mode is active Math Math style is selected as the Input/output format
D R G Angle mode: Degrees, Radians, or Gradians
FIX A fixed number of decimal places is in effect SCI A fixed number of Scientific notation is in effect
TS
Disp Displayed value is intermediate result when performing
begin on the left; those with more than 15 digits scroll to the left. Press [ X ] and [ W ] to move the cursor through an entry. However, whenever you input the 89th digit of any calculation, the cursor changes from " " to " " to let you know memory is running low. If you still need to input more, you should divide your calculation into two or more parts.
It displays a result of up to 10 digits, as well as a
decimal, a negative sign, a " x10 " indicator, and a 2-digit positive or negative exponent.
The following indicators may appear on the display to
indicate the current status of the calculator.
There are earlier or later results that can be displayed
multi-statement function
Ind icat or
39
x10
Result l ine
Before Starting Calculation
Using " MODE " keys
Press [ MODE ] to display mode menus when specifying an operating mode ( " 1: COMP ", " 2: STAT ", " 3: TABLE " ).
COMP : Use this mode for basic calculations, including
STAT : Use this mode to perform single–variable and
TABLE : Use this mode to display a defined function in a tabular
scientific calculations. (the default)
paired–variable statistical calculations and regression calculations.
form.
E – 4
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 5
Give " 2: STAT " as an example:
Method : Press [ MODE ] and then key in directly the number of
the mode, [ 2 ] , to enter the desired mode immediately.
Using " SET UP " keys
[ 2nd ] [ SET UP ] display the setup menu that enables you to specify the input /output format, the angle mode, the numeric notation, the statistical setting or the contrast adjustment. The setup menu consist of two screens which you can jump between by using [ T ] and [ S ].
T
1: MthIO 2: LineIO 3: De g 4: Ra d 5: Gra 6: Fix 7: Sc i 8 : Norm
MthIO : Math mode displays inputs and outputs in textbook
LineIO : Linear mode displays inputs and outputs in a single
Deg : Deg mode sets the angle unit to degrees (the default) Rad : Rad mode sets the angle unit to radians Gra : Gra mode sets the angle unit to gradians. Fix : Fix decimal setting (0 through 9) Sci : Scientific notation (0 through 9) Norm : Norm specifies the range (Norm1, Norm2) in which
ab/c : ab/c displays the fraction in mixed number format d/c : d/c displays the fraction in improper format (the
STAT : STAT sets the Statistical Data Editor Screen to show
Disp : Disp sets the decimal point to Dot ( . ) or Comma ( , ) (Dot is the default)
W
format. (the default)
line.
the results are to be displayed in exponential format or in non-exponential format (Norm1 is the default)
default)
or hide the FREQ column
CONTX : Contrast Adjustment
Using Math Mode
d
c
1: ab/c 2: d/c
STAT
3:
CONT
5:
_
Press [ 2nd ] [ SET UP ] [ 1 ] to enter Math mode. While in math
mode, the values for functions such as
e X, √, 3,
in a mathematically written way. By default, SR-270X is in Math
2
3
1
,
X
y
,
,
X
,x....can be entered and displayed
X
X
4: Disp
`
d
, A
e
c
b
, log a b, Abs, 10x,
c
mode. See Example 1~2.
E – 5
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 6
Using " 2nd " " ALPHA " Keys
To execute the functions marked in yellow, please press [ 2nd ] and then the corresponding key. When you press [ 2nd ], the " 2nd " indicator shown on the display indicates that you will be selecting the second function of the next key you press. If you press [ 2nd ] by mistake, simply press [ 2nd ] again to remove the " 2nd " indicator.
To execute the functions marked in green, please press [ ALPHA ] and then the corresponding key. When you press [ ALPHA ], the "A" indicator shown on the display indicates that you will be selecting the alphabetic function of the next key you press. If you press [ ALPHA ] by mistake, simply press [ ALPHA ] again to remove the " A " indicator.
Making corrections during Input
The vertical blinking cursor " " means the calculator is in insert mode. The horizontal blinking cursor " " means the calculator is in overwrite mode.
By default, the calculator is in insert mode. In linear format, you can press [ 2nd ] [ INS ] to switch between the two modes, whereas in Math format, you can use only the insert mode.
In insert mode, the character in front of the cursor " " will be deleted or inserted after you press [ DEL ] or enter a new character
In overwrite mode, the character at the cursor " " will be deleted by [ DEL ] key or replaced by any new character you enter.
To clear all characters, simply press [ AC ] in either mode.
Error Position Display Function
When a mathematically illegal calculation performed causes an error and an error message ( See < Error conditions > ) appears, press [ W ] [ X ] and then the error position display function will tell you with the cursor where the error is. In that case, please make necessary corrections before executing the calculation again. See Example 3.
Replay function
This function stores operations that just have been executed in COMP mode. After execution is completed, pressing [ T ] or [ S ] key will display the operation executed.
You can continue moving the cursor by [ W ] or [ X] to display previous input steps and editing values or commands for subsequent execution.
The operation records in Memory are cleared each time when you turn off the calculator, press [ ON ] key, perform a “reset”, change display format or calculation mode.
When the memory is full, the oldest calculation records are deleted automatically to make room for the new ones. See Example 4.
E – 6
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 7
Memory calculation
Memory variable
The calculator has seven memory variables for repeated use -- A, B, C, D, M, X, Y. You can store a real number in any of the seven memory variables. See Example 5.
• [ 2nd ] [ STO ] + [ A ] ~ [ D ], [ M ], [ X ] ~ [ Y ] lets you store values
to variables.
• [ RCL ] + [ A ] ~ [ D ], [ M ], [ X ] ~ [ Y ] recalls the value of the
variable.
• [ 0 ] [ 2nd ] [ STO ] + [ A ] ~ [ D ], [ M ], [ X ] ~ [ Y ] clears the
content to a specified memory variable.
• [ ALPHA ] + " memory variable " lets you insert the applicable
variables in a calculation.
• [ 2nd ] [ CLR ] [ 2 ] [ = ] clears all variables.
Running memory
You should keep the following rules in mind when using running memory. See Example 6.
• Press [ M+ ] to add a result to running memory and the " M "
indicator appears when a number is stored in the memory. Press [ RCL ] [ M ] to recall the content of running memory.
• Recalling from running memory by pressing [ RCL ] [ M ] key does
not affect its contents .
• Running memory is not available when you are in statistics mode.
• The memory variable M and running memory utilize the same
memory area.
• In order to replace the content of the memory with the displayed
number, please press [ 2nd ] [ STO ] [ M ] key.
• To clear the content of running memory, you can press [ 0 ] [ 2nd ]
[ STO ] [ M ] in sequence.
(Note) : Besides pressing [ 2nd ] [ STO ] [ M ] key to store a value,
you can also assign values to memory variable M by [ M+ ]. However, when [ 2nd ] [ STO ] [ M ] is used, previous memory contents stored in variable M are cleared and replaced with the newly assigned value. When [ M+ ] is used, values is added to present sum in memory.
Order of operations
Each calculation is performed from left to right and in the following order of precedence:
1) Expression inside parentheses.
2) Functions with parentheses:
PR, R P sin, cos, tan, sin –1, cos –1, tan –1, sinh, cosh, tanh, sinh –1,
cosh –1, tanh –1,
log, ln, √, 3, 10 X , e X , Abs, RND
E – 7
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 8
3) Functions preceded by values, powers, power roots, for example, x 2, x 3, x–1, x!, DMS, ° , r , g , x y, X, %
4) Fractions
5) Negations ( – )
ˆ
ˆ
ˆ
6) Statistical estimated value calculation:
7) nPr, nCr
8) x , Multiplication sign omitted immediately before function with parentheses: for example, 3π, 5B, Asin(30)
9) +, –
Accuracy and Capacity
Output digits : Up to 10 digits.
Calculating digits : Up to 16 digits
In general, every reasonable calculation is displayed up to 10 digits mantissa, or 10-digit mantissa plus 2-digit exponent up to 10
Numbers used as input must be within the range of the given function as follows:
Functions
sin x cos x
tan x
sin –1 x, cos –1 x tan –1 x
sinh x, cosh x
tanh x
sinh –1 x
cosh –1 x tanh –1 x
log x, ln x 10 x e x
x
x 2
Deg : 0
Rad : 0
Grad : 0 Same as sin x, except when
Deg :
Rad :
Grad :
0
0
0
0
0 1 x < 5 x 10 99
0 0 < x < 1 x 10
–1 x 10 –1 x 10 0 x < 1 x 10
x
< 1 x 10 50
Input range
x
< 9 x 10 9
x
< 157079632.7
x
< 1 x 10 10
x
= 90 (2n-1)
π
x
=
(2n-1)
2
x
= 100 (2n-1)
x
1
x
x
x
x
x
100
100
100
< 1 x 10
230.2585092
100
< 1 x 10 < 5 x 10 99
< 1
100
x 100 x 230.2585092
100
,
x
,
,
y
1x
π,
ˆ
2x
e, variable, and
± 99
.
E – 8
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 9
x 3
x -1
3
x
X ! nPr
nCr
R P
P R
DMS eDMS
x y
x
y
Ab/c
STAT
Error conditions
Error message will appear on the display and further calculation becomes impossible when any of the following conditions occur.
Indicator Meanings
Math ERROR
x
2.15443469003 x 10 33
1 x 10 < 1 x 10
100
100
, x0
x
x
0 x 69 ( x is an integer) 0rn, 0n<1 x 10 10 (n,r are integers) 1{n!/(n-r)!}<1 x 10 0rn, 0n<1 x 10 10 (n,r are integers) 1n!/r!<1 x 10
y
,
x
22
y+x
0 r 1 x 10
θ: same as sin x D, M, S 1 x 10
x
< 1 x 10
Decimal Q Sexagesimal Conversions
׀ ׀
0  0 ׀ 0 x > 0 : –1 x 10
x = 0 : y > 0 x < 0 : y = n, m/(2n+1) (m, n are integers) but –1 x 10
y > 0 : x 0, –1 x 10 y = 0 : x > 0
y < 0 : x = 2n+1, (2n+1)/m (m0, m, n are integers)
but –1 x 10
Total of integer, numerator and denominator must be within 10 digits (includes division marks)
1–VAR :
a. n 80 lines (when FREQ column is OFF) b. n 40 lines (when FREQ column is ON)
2–VAR :
a. n 40 lines (when FREQ column is OFF) b. n 26 lines (when FREQ column is ON)
(1) You attempted to divide by 0 (2) When allowable input range of function
calculations exceeds the range specified
100
100
or 1≦{n!/(n-r)!}<1 x 10
100
1 x 10
100
1 x 10
100
100
x
9999999  59 ׀ 59
100
< y log x < 100
100
< y log x < 100
100
1
100
<
log ⏐y⏐ < 100
x
100
, 0 M, S
1
<
x
100
׀ ׀
log y < 100
E – 9
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 10
(3) When result of function calculations
exceeds the range specified
(4) When specifying an argument to a function
Syntax ERROR
Stack ERROR
Insufficient MEM
Error
To release the above errors, please press [ W ] [ X ] to correct your error, or press [ AC ] key to cancel your calculation, or simply press [ ON ] key to reinitialize the calculator.
outside the valid range
(1) Input errors are made, ex. improper syntax (2) When improper arguments are used in
commands or functions
When a calculation expression exceeds the capacity of the numeric stack or command stack, ex.
When the [ ( ] key is used more than 25 levels in a single expression in linear mode
When there is insufficient memory to store data or perform your calculation
Basic Calculations
Use COMP ( [ MODE ] 1 ( COMP ) ) mode for basic calculations.
Arithmetic calculation
Arithmetic operations are performed by pressing the keys in the same sequence as in the expression. See Example 7.
For negative values, press [ (–) ] before entering the value.; You can enter a number in mantissa and exponent form by [ x10x ] key. See Example 8.
Results equal to or greater than 10 10 or results less than 10 –9 are displayed in exponential form. See Example 9.
Parentheses calculations
Operations inside parentheses are always executed first. SR-270X Math mode can use up to 24 levels and Linear mode can use up to 25 levels of consecutive parentheses in a single calculation.
Closed parentheses occurring immediately after operation of the [ ) ] key may be omitted, no matter how many are required. See Example
10.
(Note) : A multiplication sign " x " occurring immediately before
The correct result cannot be derived by entering [ ( ] 2 [ + ] 3 [ ) ] [ x10x ] 2. Be sure to enter [ x ] between the [ ) ] and [ x10x ] in Example 11.
an open parenthesis can be omitted.
E – 10
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 11
Percentage calculation
[ 2nd ] [ % ] divides the number in the display by 100. You can use this key sequence to calculate percentages, add-ons, discounts, and percentage ratios. See Example 12~13.
Display notations
The calculator has the following display notations for the display value. See Example 14.
Fixed Decimal Point Notation
To specify the number of decimal places, press [ 2nd ] [ SET UP ] [ 6 ] and then a value indicating the number of places ( 0~9 ). Values are displayed rounded off to the place specified.
Scientific Notation
Scientific notation expresses numbers with one digit to the left of the decimal and the appropriate power of 10.
To select scientific notation, press [ 2nd ] [ SET UP ] [ 7 ], and then a value (0~9) to specify the number of decimal digits. Values are displayed rounded off to the place specified.
Norm Notation
Press [ 2nd ] [ SET UP ] [ 8 ] and then select Norm1 (the default) or Norm2 to determine the range to display the result in non-exponential format (within the range) or in exponential format (out of the range).
Norm1:
Norm2:
Engineering Notation
Pressing [ ENG ] or [ 2nd ] [ eENG ] will cause the exponent display for the number being displayed to change in multiples of 3.
Answer function stores the most recently calculated result. It is retained even after the power is turned off. Once a numeric value or numeric expression is entered and [ M+ ], [ 2nd ] [ M– ], [ RCL ], [ 2nd ] [ STO ] or [ = ] is pressed, the result is stored by this function. See Example 15.
<
x
<
x
Answer Function
(Note) : Even if execution of a calculation results in an error,
however, Answer memory retains its current value.
10 -2,
10 -9,
10 10
x
10 10
x
Scientific Function Calculations
Use COMP ( [ MODE ] 1 ( COMP ) ) mode for scientific function calculations.
E – 11
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 12
Logarithmic and Exponential functions
The calculator can calculate common and natural logarithms, and exponentiation using [ log ], [ ln ], [log a b], [ 2nd ] [ 10 x ], and [ 2nd ] [ e x ]. See Example 16~17.
Fraction calculation
Fraction value display is as follows:
Math format:
Linear format:
(Note) : Values are automatically displayed in decimal format
In Linear mode, to enter a mixed number, enter the integer part, press [ d/e ], enter the numerator, press [ d/e ], and enter the denominator ; To enter an improper fraction, enter the numerator, press [ d/e ], and enter the denominator. See Example 18.
During a fraction calculation, if the figure is reducible, a figure is reduced to the lowest terms after pressing the [ = ] key. The initial default for a fraction result is improper fraction. By pressing [ 2nd ]
d
[ A b/
_`
c fraction and vice versa. To convert between a decimal and fractional result, press [ F_`D ]. See Example 19.
Calculations containing both fractions and decimals are calculated in decimal format. See Example 20.
Angle unit conversions
The angle unit ( from Setup screen and results are displayed according to your setting.
The relation among the three angle units is:
180 ° =πrad = 200 grad
Angle unit conversions (See Example 21.):
1) Change the default setting (
to.
2) Enter the value of the unit to convert.
3) Press [ 2nd ] [ DRGf] to display the menu. The units you can
select are ° (
4) Select the unit you are converting from, and press [ = ].
Improper Fraction
whenever the total number of digits of a fractional value ( integer + numerator + denominator + separator marks ) exceeds 10.
/e ], the displayed value will be converted to the mixed
Deg, Rad, Grad
degrees
12
5
12 」5
) is set by pressing [ 2nd ] [ SET UP ]
) to the unit you want to convert
Deg
), r (
radians
), g (
Mixed Fraction
gradians
5
56
12
56 」5 」12
).
E – 12
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 13
Sexagesimal ↔ Decimal transformation
You can use sexagesimal figure (degree, minute and second) to perform calculations and convert values between sexagesimal and decimal notation by using [ DMS ] or [ 2nd ] [ eDMS ] keys. See Example 22~23.
Sexagesimal figure value display is as follows:
׀ ׀
125
45 ׀ 30
Trigonometric / Inverse-Tri. functions
SR-270X provides standard trigonometric functions and inverse trigonometric functions: sin, cos, tan, sin –1, cos –1 and tan –1. See Example 24~26.
(Note) : When using those keys, make sure the calculator is set
for the angle unit you want.
Hyperbolic / Inverse-Hyp. functions
SR-270X uses [ HYP ] to calculate the hyperbolic functions and inverse-hyperbolic functions: sinh, cosh, tanh, sinh –1, cosh –1 and tanh –1. Press [ HYP ] to display the menu and then select the corresponding number to perform the function item. See Example 27~28.
(Note) : When using those keys, make sure the calculator is set
for the angle unit you want.
Coordinates transformation
Rectangular Coordinates Polar Coordinates
Represent 125 degrees (D), 45 minutes(M), 30 seconds(S)
x + y i = r (cosθ+ i sinθ)
(Note) : When using those keys, make sure the calculator is set
The calculator can perform the conversion between rectangular coordinates and polar coordinates by [ 2nd ] [ P R ] and [ 2nd ] [ R P ]. See Example 29~30.
This calculator provides the following probability functions (See Example 31~34.):
[ nPr ] Calculates the number of possible permutations of n item
for the angle unit you want.
Probability
taken r at a time.
E – 13
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 14
[ nCr ] Calculates the number of possible combinations of n
items taken r at a time.
[ x ! ] Calculates the factorial of a specified integer n , where n
RANDM
[
The calculator also provides reciprocal ( [ x cubic root ( [ 2nd ] [ ( [ x 2 ] ), cubic ( [ x 3 ] ), and exponentiation ( [ x y ] ) functions. See
Example 35~39.
Abs
RND
A Multi-statement is a number of individual statements grouped together by display result commands (:) for sequential execution. When execution reaches the end of a statement followed by (:), execution stops and an intermediate result with a " Disp " icon appears on the display. You can resume execution by pressing [ = ]. " Disp " icon disappears when the last statement is being executed. See Example 40.
69.
] Generates a random real number between 0.000 and
0.999.
Other functions ( √, 3, X, x-1, x2, x3, xy , Abs, RND )
3
] ), universal root ( [ 2nd ] [ X ] ), square
Generates the absolute value of a real number
Generates the rounding value of a given number
Multi-statement Function
-1 ]
), square root ( [ √ ] ),
Statistical Calculations
Use STAT ( [ MODE ] 2 ( STAT ) ) mode for statistical calculations.
When you enter STAT mode, you are taken to the STAT menu with a choice of eight calculation types as follows:
Single–variable statistics
1: 1–VAR Single-variable statistics
Paired-variable / Regression statistics
2: A+BX Linear Regression Y = A + BX
2
3: _+CX 4: ln X Logarithmic Regression Y = A + B lnX 5: e^X e Exponential Regression Y = A • e BX
6: A•B^X ab Exponential Regression Y = A • B X 7: A•X^B Power Regression Y = A • X B 8: 1/X Inverse Regression Y = A + B / X
Quadratic Regression Y = A + BX + CX 2
E – 14
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 15
To Enter data for statistical analysis
Before entering data, press [ 2nd ] [ SET UP ] [ T ] [ 3 ] in sequence to set Frequency column as On or Off. enter the number of repeats for each of the same value occurred. See Example 41.
1. From the STAT menu, choose a calculation type. There will be two Data Editor formats ( depending on the type you select.
2. Enter an x - value and press [ = ].
3. Enter the frequency ( the corresponding y-value ( in
4. To enter more data, repeat from step 3.
5. To exit Data Editor mode to Result displaying mode, press [ AC ] and then [ 2nd ] [ STATVAR ] to display STATVAR menu. ( See table below )
To analyze data you have entered
Once you have entered your data, you can use the functions in STATVAR menu by pressing [ 2nd ] [ STATVAR ]:
STATVAR Menu Meaning
1: Type Statistical calculation type menu, see the 8 types
2: Data The data editor screen
3: Edit The editing commands sub-menu: [Ins], [Del-A]
4: Sum The summation sub-menu
5: Var The statistical variable sub-menu
6: MinMax The maximum/minimum sub-menu
7: Reg (2-VAR) The regression sub-menu
Use options 1~3 to view or change data. Use options 4~7 to select the desired variable to analyze your data.
The values of the statistical variables depend on the data you input. You can recall them by the key operations shown in the below table.
Single–variable statistics calculations
Variables Keys Meaning
Σ
Σ
n [5: Var] [ 1 ] Number of the x values entered
x
xσn
[4: Sum] [ 1 ] Sum of all x 2 values
x 2
[4: Sum] [ 2 ] Sum of all x values
x
[5: Var] [ 2 ] Mean of the x values
[5: Var] [ 3 ] Population standard deviation of x
1–VAR
) of the x-value (in
FREQ
as previously mentioned in STAT menu
values
column enables you to
FREQ
or
2–VAR / regression Data)
1–VAR
mode ) and press [ = ].
2–VAR
mode) or
E – 15
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 16
xσn-1
[5: Var] [ 4 ] Sample standard deviation of x
values
minX [6: MinMax] [ 1 ] Minimum of x-value
maxX [6: MinMax] [ 2 ] Maximum of x-value
Paired-variable statistics / Regression calculations
Variables Keys Meaning
Σ Σ
Σ Σ
Σ Σ
Σ
Σ
[4: Sum] [ 2 ]
x
[4: Sum] [ 4 ]
y
2
[4: Sum] [ 1 ]
x
2
[4: Sum] [ 3 ]
y
3
[4: Sum] [ 6 ]
x
4
[4: Sum] [ 8 ]
x
[4: Sum] [ 5 ] Sum of ( x • y ) for all x-y pairs
x y
[4: Sum] [ 7 ] Sum of ( x2 • y ) for all x-y pa irs
x 2 y
Sum of all x values or y values
Sum of all x 2 values or y2 values
Sum of all x 3 values or x4 values
n [5: Var] [ 1 ] Number of x-y pairs entered
x
y
xσn-1
yσn-1
xσn
yσn
[5: Var] [ 2 ] [5: Var] [ 5 ]
[5: Var] [ 4 ] [5: Var] [ 7 ]
[5: Var] [ 3 ] [5: Var] [ 6 ]
Mean of the x values or y values
Sample standard deviation of x values or y values
Population standard deviation of x values or y values
minX [6: MinMax] [ 1 ] Minimum of x-value
maxX [6: MinMax] [ 2 ] Maximum of x-value
minY [6: MinMax] [ 3 ] Minimum of y-value
maxY [6: MinMax] [ 4 ] Maximum of y-value
A [7: Reg] [ 1 ]
Regression coefficient constant term A
B [7: Reg] [ 2 ] Regression coefficient B
For non-Quadratic Regression :
r [7: Reg] [ 3 ] Correlation coefficient r
[7: Reg] [ 4 ] Estimated value of x
ˆ
x
[7: Reg] [ 5 ] Estimated value of y
ˆ
y
For Quadratic Regression (_+CX2) only :
C [7: Reg] [ 3 ] Quadratic coefficient C of the regression
[7: Reg] [ 4 ] Estimated value of x1
ˆ
1
x
coefficients
E – 16
File name : HDB0R100704_English_text_071113
version : 07/10/15
Page 17
[7: Reg] [ 5 ] Estimated value of x2
ˆ
2
x
[7: Reg] [ 6 ] Estimated value of y
ˆ
y
You also can add a new data anytime. The unit automatically recalculates statistics each time you press [ = ] and enter a new data value.
To view or change data
1. Press [ 2nd ] [ STATVAR ] [ 2 ] to enter Editor Screen.
2. Press [ T ] or [ S ] to scroll through the data you have entered.
3. To
data you enter overwrites the old entry. Press [ = ] to save the change.
4. To
delete, press [ DEL ].
5. To
you want to insert, press [ 2nd ] [ STATVAR ] [ 3 ] and then select [ 1 ] (Ins) to create a new blank entry, fill the new data in the blank and press [ = ].
6. To
select [ 2 ] (Del-A) to clear all data on the Editor Screen.
(Note) : Statistical data and results are retained when the
Function Table
Use TABLE ( [ MODE ] 3 ( TABLE ) ) mode for generation of a function table.
TABLE mode lets you define a function and express it in a tabular form. To set up a function table, you need to: (See Example 42.)
1. Press [ MODE ] [3] (TABLE)
2. Enter a function, and press [ = ]
3. Input the Start, End, and Step value of X, and press [ = ]
4. After Step 3, a table of values that consists of each input, X, and
its corresponding output, f(X), is generated.
(Note) : 1. Only the variable X is available to be used in a
2. The Start, End, and Step value you specify should
an entry, display it and enter the new data. The new
change
an entry, position the cursor on the line you want to
delete
an entry, position the cursor on the line above where
insert
entries, press [ 2nd ] [ STATVAR ] [ 3 ] and then
delete all
calculator is turned off, but are cleared when you change calculation types, FREQ setting or clear data by selecting Del-A command from STATVAR menu.
function.
produce a table not exceed a maximum of 30 X-values.
E – 17
File name : HDB0R100704_English_text_071113
version : 07/10/15
Loading...