Citizen CA0369-11E, CA0540-56L, CA0564-58E, CA0611-09H, CA0611-50E Instruction manual

(cal.B612)
PAE07
Instruction Manual
Thank you for your purchas e of this Citizen watch. B e f ore us in g the wa t c h , read th is instruction manual carefully to ensure correct use. Aer reading the manual, store it in a safe place for future reference.
To check the movement number
A case number is engraved on the case back. (See the gure below.) On the case back, a number composed of four + six alphanumeric characters (or more) is engraved. In the example below, “1234” is the movement number.
<Engraving position example>
1
2
3
4
e engraving position may dier depending on watch model.
Safety precautions
(Instructions to be followed at all times)
is manual contains the following ins tructi ons that sh ould be strict ly followed at all times to preve nt injur y to yourself and other persons as well as damage to property.
■ Inju rie s and dama ge th at mi ght be caused by using the watch improperly or neglecting any of the instructions or precautions contained in this manual are classied with the following symbols.
DANGER
WARNING
CAUTION
■ Impor tant instructions that should be followed are classied with the following symbols.
Warning (caution) symbol followed by instructions that should be followed or precautions that should be observed.
Warning (caution) symbol followed by prohibited matters.
Specications
Cal. No.: B612
Type: Analogue solar powered
Time accuracy: Within +/-15 seconds per
Operational temperature range:
Display functions:
Additional functions:
Operation time:
Battery: Rechargeable cell
1234-567890
0
9
8
-
7
5
6
Highly likely to cause death or serious injury.
Can cause serious injury or death.
Can or will cause minor or moderate injury or damage.
watch
month when worn at normal operating temperatures (+5°C to +35°C)
−10°C to +60°C
Time: Hour, minute, second, and 24-hour Calendar: Date (does not automatically adjust for months shorter than 31-days)
Chronograph (measures up to 60 minutes in 0.2-second units), Insucient Charge Warning Function, Overcharge Prevention Function, Quick Start Function
Time until stop from full charged status without additional charging: Approx. 7 months Time until stop from activation of insucient charge warning function: Approx. 7 days
(lithium button cell),1pc
Notes Before Use
<Notes before use — Protective stickers>
Prior to the watch being shipped from the manufacturing plant, its glass, case, metal band, and metal parts of clasp are covered with stickers to protect them from getting ngerprint or scratches during transit from the plant to the store. If the watch is worn without first removing these stickers, perspiration or moisture may enter the gaps between the protective stickers and the parts, which may result in a skin rash a skin rash and/or corrosion of the metal parts. For this reason, please be sure to peel o stickers before wearing the watch.
Notes on charging your watch
is watch has a rechargeable cell which is charged by exposing the dial to light, such as direct sunlight or uorescent lamps. Aer taking o the watch, put it in a location where the dial is exposed to bright light, such as by a window.
For optimal performance, perform the following:
• Expose the watch with the
dial facing towards direct
sunlight for ve to six hours
at least once a month.
• Before storing the watch in a dark place for an extended
period of time, be sure to charge it fully.
• When the watch is regularly covered with long sleeves,
it may not be charged suciently. Try to keep the watch exposed to light sucient for charging.
• Do not charge the watch at a high temperature (about 60ºC
or higher).
About the crown
Some models use screw down system for the crown. Accidental operations can be prevented when the watch is not being operated by locking the crown. To operate the watch, release the lock.
• If your watch does not have a screw down crown,
operations can be performed without locking or unlocking the crown.
Before operation
Unlock the crown
Rotate the crown t o the left (counterclockwise).
When the screw lock is released , the crown ex tends to the normal position.
After operation
Lock the crown
Pres s th e cr own and rotate it to the right (clockwi se) to tighten the screw lock.
Your Watch
Eco-Drive (solar powered) watch
Th e watc h operat es by co nve r ting su nlig ht and other light into electrical energy. Once the rechargeable cell is fully charged, the watch will function for approximately 7 months.
Insufficient charge warning
If the power becomes very low, the second hand advances at 2-second intervals, indicating that charging is necessary. When the second hand starts to advance at 2-second intervals, expose the watch to light until it is fully charged.
If the watch is not exposed to light wit hin approxi mately 7 days afte r the insufficient charge warning st arts, the watc h will stop.
Quick start function
When the stopped watch is exposed to light, it starts operating again immediately.
After quick start, expose the wa tch to light until it is fully charged. Set the correct time before using the watc h.
Replacement of Rechargeable Cell
Because the watch uses a rechargeable cell, you do not need periodical cell replacement. Howe ver, po wer c onsumptio n may incre ase after using for an extended period of time due to deterioration, and the power may run out earlier than expected. To avoid this, we recommend that you have your watch inspected (Charge basis) periodically.
Component identication
Chronograph minute hand
Chronograph second hand
Hour hand
Button (B)
Minute hand
Crown
Date indicator
24-hour hand
Second hand
* e illustrations shown in this manual may dier
from the actual watch you have purchased.
Button (A)
Setting the Time
Pull the crown out to
1
position 2.
Pull out the crown just as the second hand is at the reference position in order to accurately align to the second.
Rotate the crown to set the time.
2
Move the minute hand ahead of the correc t time by 5 “minutes” a nd t hen re turn t he han d to the correct “minutes”. is will minimize the eect of gear play and will provide more accurate hand movement.
e 24-hour hand (located at the 9:00 subdial) moves in relation to the hour hand. Determine whether it is a.m. or p.m. by observing the 24-hour hand.
Press the crown
3
back into its normal position.
Be sure to secure if the watch has a screw down crown.
Water may enter your watch.
Setting the Date
Pull the
1
crown out to position 1.
e date must be manually adjusted for months shorter than 31-days. You will need to adjust the date at the start of March, May, July, October and December. Do not adjust the date between 9 p.m. and 1 a.m. If you change the date during this time, the date may not change the following day.
Rotate the crown
2
counterclockwise to set the date. The date will not change when the crown is rotated clockwise.
e date does not change when you rotate the crown to the right.
Press the crown back into its
3
normal position.
Be sure to secure if the watch has a screw down crown. Water may
enter your watch.
Using the Chronograph
e chronograph can measure up to 60 minutes in 0.2-second units.
Chronograph minute hand
Reference position of the chronograph minute hand
Reference position
Time measurement start/stop [button(B)]
To start the chr onograph, press and r elease the upper rig ht
button (B) to co mmence time measurem ent. To stop the chronograph, pres s and release the upper right
button (B) ag ain. To recommence timi ng from the stopped p osition, press and
release th e upper right butto n (B) again.
Pressing and releasing the lower right button (A) during chronograph operation will cause timing to stop and the chronograph to reset.
Reset [button(A)]
Chronograph second hand
Caution
e chronograph minute/second hands may be come misaligned if the watch is subjected to a strong knock. If the position cannot be corrected by using the reset procedures outlined on pages 12-13, please contact your nearest Authorized Service Center.
e chronograph does not function if the crown is pulled out to position 2. e chronograph resets if the crown is pulled out to position 2 during measurement.
To reset the chrono graph after stop ping time measuremen t, press and re lease the lower right but ton (A).
When the chronograph second hand does not return to the reference position
If the chronograph second hand does not return to reference position even when reset, perform the following procedures to align the chronograph second hand with the reference position.
Set the watch to correct
1 2 3
the reference position
P
ull the
2
crown out to position 2.
1
Press and hold the upper
right button (B) for 3 seconds or more. The watch is now set to correct the reference position.
Be sure to secure if the watch has a screw down crown and/or screw down push button. Water may enter your watch.
Correct the position of the second hand Reset the minute hand
Press and release
1
· Press once
· Press and h old down
If the second hand does not move even when the upper right button (B) is pressed, perform Step of the page on the le.
1
Press the crown back into its
normal position.
the upper right button (B) to adjust the position of
2
the chronograph second hand.
Second hand moves ahead at one-second intervals.
Second ha nd advances r apidly.
Time is stopped while aligning with the reference position. Set the time aer aligning.
Press and release the lower right button (A) to adjust the position of the chronograph minute hand.
e chronograph minute hand moves together with the second hand when correcting the second hand. Reset the minute hand.
Guide to Charging Time
Below are the approximate times needed for charging when exposing the watch dial to light continuously. Please use this table as a reference only.
(Lx)
Charging
time to work
for one day
2 to 11
minutes
Environment
Under direct sunlight or cloudy weather (not through a window)
20 cm under a uorescent lamp (30 W)
Interior lighting 500 3.5 hours 80 hours
To charge the rechargeable cell fully, it is recommended to expose the dial to direct sunlight.
*
A uorescent lamp or interior lighting does not have sucient illumination to charge the rechargeable cell fully.
Illuminance
10,000
to 100,000
3,000 35 minutes 11 hours 150 hours
Charging time to start
working normally when the
rechargeable cell is empty
25 minutes
to 3.5 hours
Charging time to the fully
charged state when the
rechargeable cell is empty
8.5 hours
to 45 hours
is watch wil run for approximately 7 months from a full charge without further exposure to light.
Precautionary Items and Usage Limitations
CAUTION
· Be p art icu larl y c aref ul when wea rin g yo ur watc h wh ile holdin g a small chi ld, to avoid inju ry.
· Be part icularly carefu l when engaged in str enuous exe rcise or work, to avo id injury to you rself and ot hers.
· Do NOT wear your wa tch while i n a sauna or other locat ion
WARNING
· Non-w ater resis tant wat ches ca nnot be used u nderwater or in envi ronments in c ontact with w ater.
· Water-resis tance for da ily use (to 3 atmos pheres) means t hat the watch may b e worn while washi ng you r face or in t he rain , but is not to be imme rsed in water.
· Upg raded w ater-resista nce for daily use (to 5 atmos pheres) means that t he watch ma y be worn while sw imming , but is not to worn w hile skin d iving.
Name
Non-water-
resistant watch
Everyday-use
water-resistant
watch
Upgraded
everyday-use
water-resistant
watch
Upgraded
everyday-use
water-resistant
watch
CAUTION
· Always use the watc h wi th t he c rown pushed in (norma l positi on). If t he crown is of t he screw lock-ty pe, mak e sure it is securely locked.
· Do NOT operate the crown when the watch i s wet . Water may pe netr ate int o t he w atc h, c ausi ng det erio rat ion of water res istance.
· If water ent ers the watch or the watc h fogs up and doe s not cl ear up eve n a fte r a lon g ti me, co nsu lt y our de ale r or Custome r Support Cente r for inspect ion and/or repa ir.
· If a wat ch of u pgr aded wa ter res ista nce for da ily us e is im mers ed in se a wat er o r sub ject ed t o exc essive pers pirati on, t horough ly r inse with fres h wate r and wip e complete ly dry wit h a soft cloth .
· If s eawate r en ters the watc h, pl ace the watch in a b ox or plast ic bag and im mediately t ake it in for repair. Ot herwise, pressu re ins ide th e watch wil l incr ease, and p arts (crystal , crown, b uttons, etc.) may c ome off.
CAUTION
<Band>
· T he dura bility of a leather band m ay be affecte d when wet (fadin g, peeli ng of adh esive), owing to the p roperties of the materi al. Moreover, wet le ather may caus e a rash.
· It is recommended to take off the watch if it gets wet, even if the watc h itself is wat er-resista nt.
· Do Not w ear the ba nd too tig htly. Try to leav e enough spa ce be tween the ban d an d yo ur s kin to all ow a dequ ate ventilation .
· T he rubbe r (uretha ne) band may be staine d by dy es or s oil present i n or on clothin g or other acces sories.
Since these stai ns may not be removable, caution is required
whe n we arin g yo ur w atch wit h it ems that tend to easi ly tran sfer color (ar ticles of clo thing, pu rses, etc .). In additi on, the ba nd may be det eriorated by solvents or mo isture in the ai r. Rep lace with a new o ne wh en it has los t ela stic ity or become cracked.
<Temperature>
· The w atch may s top or the fun ction of the w atch may b e impai red in extr emely high or low te mperature .
Do not use the watch in places where the temperature is
outs ide the operat ing temper atur e ra nge a s st ated in the specif ications.
<Stati c Electric ity>
· The inte gra ted circ uit s (I C) u sed in qua rtz wat ches are sensit ive to stat ic electr icity. Pleas e note that the watch may not ind icate the corr ect time if expo sed to i ntense sta tic electric ity.
<Magnetism>
· Analo g qua rtz watch es a re p owered by a ste p moto r th at uses a m agnet. Subjec ting the w atch to stron g mag netism from t he outside ca n cause the motor to operat e improperly and pre vent the wat ch from ind icating t he correc t time. D o not a llo w t he w atc h to com e in to c los e pr oxi mit y to magnetic health devices (mag netic neck laces, magnetic ela stic band s, etc.) or t he m agne ts u sed in t he l atche s of refri gerator doors , clasps us ed in handba gs, the spe aker of a cell pho ne, electrom agnetic co oking dev ices and so on.
<Stron g Shock>
· Avoid droppin g the watch or subject ing i t to other strong imp act. It may caus e ma lfu nct ions and /or pe rfor manc e deter ioration as wel l as damage to t he case and br acelet.
<Chemi cals, Corros ive Gasses and M ercury>
· If p ain t t hin ner, ben zene or oth er s olv ents or prod uct s containing these solvents (including gasoline, nailpolish remo ver, c resol, bat hroom clea ners and adhe sives, wate r repe llent, etc .) are al lowed to co me in to co ntact with the watch, the may discolor, dissolve or crack the mate rials. Be ca ref ul whe n ha nd lin g t hes e ch emi cal s. Cont ac t wi th mercur y such a s that u sed in t hermometer s may al so cause disco loration of the b and and case .
To avoid injury
Water Resistance
Indication
Watch face or
case back
WATER RESIST (ANT)
WATER RESIST (ANT)
5 bar
WATER RESIST (ANT)
10/20 bar
Precautions
When Wearing your Watch
Specications
Non-water-
resistant
Water-resistant to
3 atmospheres
Water-resistant to
5 atmospheres
Water-resistant to
10 or 20
atmospheres
where your w atch may become excessive ly hot, since there is the r isk of burns.
· Be ca reful wh en putting on and tak ing off yo ur watch, si nce there is a risk o f dama ging you r fin gernails , depend ing on the ma nner in which t he band is fas tened.
· Upg rad ed water- resi sta nc e for dail y us e (to 10/2 0 atmospheres) means that t he watch may be worn while ski n di vin g, but not wh ile scu ba or s atu rat ed div ing us ing helium g as.
· Refe r to t he watch dial a nd the case ba ck for t he indi cation of the wa ter resi stance of you r watc h. The follow ing cha rt provide s exa mples of use for refe rence to ensure that your watch is used pr operly. (The unit “1bar” is rough ly equal to 1 atmosphere.)
· WATE R R ESIS T(AN T) ××ba r ma y a lso be indi cat ed a s W.R .× ×ba r.
Water-related use
Minor
exposure to water (washing face, rain, etc.)
Moderate
exposure to
water (washing,
kitchen work,
swimming, etc.)
Skin diving,
marine
sports
Scuba diving
an air tank
NO NO NO NO NO
OK NO NO NO NO
OK OK NO NO NO
OK OK OK NO NO
CAUTION
· Rotate the c rown w hile it is presse d in ful ly and press the but tons period ical ly s o th ey d o not bec ome s tuck due t o accu mulations of fore ign matter.
· The c ase and b and of th e wat ch co me in to di rect contac t wi th the sk in in t he sam e ma nn er a s u nder gar men ts. Cor rosion of t he m etal or unnot iced soili ng s uch a s th at cause d by perspir ation a nd di rt c an so il sle eves and ot her port ions of clothi ng. Keep your wat ch clean at al l times.
· The c ase and b and of th e wat ch co me in to di rect contac t wi th t he ski n. Rust , d irt or pers pira tio n pre sent on the watch 's body or ba nd may cause itching or a rash on yo ur skin . Such problems may al so occ ur if you ha ve an allerg y to cer tain me tals or le ather. If y ou think there is somethin g wro ng, disc ontin ue we ari ng t he w atch imme diate ly a nd consu lt your physicia n.
· Leathe r ba nds m ay be come discol ored b y per spirat ion or dirt. Always keep your leather band clean by wiping w ith a dry c loth.
CAUTION
· Wipe any d irt or m oistu re su ch a s per spira tion from the case a nd crysta l with a sof t cloth.
· F or a metall ic, pla stic or rubbe r watchb and, w ash a ny dir t off with water. Remove t he sma ll a mounts of dir t tr apped betwe en the crevi ces of the meta llic band w ith a soft br ush.
· If you wi ll not be usi ng your watch for a n extended pe riod of time , care fully wipe off any p erspirati on, di rt or moistu re and store in a proper location, avoidin g locations subject to exces sively high or low t emperature s and high hum idity.
<About t he Watch with Lu minous Paint >
The paint on the dial and h ands he lps you with reading the time in a da rk plac e. Th e lumi nous p aint s tores d aylight or ar tif icia l l ight (not in clud ing inca nde scent li ghti ng) and glows i n a dark place. It is free f rom any radio active subs tance or any ot her materia l harm ful to a huma n body or envir onment.
· The lig ht emi ssio n g rad ual ly bec omes we ake r as ti me passes.
· The du ration of the lig ht (“glow ”) wi ll v ary dependin g on the brig htness, ty pes o f and dist ance from a li ght s ource, expos ure time, a nd the amount of t he paint.
· The pain t ma y not gl ow a nd/or may dis sipat e qu ick ly i f expos ure to light wa s not suffi cient.
WARNING
· The r echar geabl e cel l s hould never be remove d f rom t he watch. If for any reason it be comes nece ssary to remove the recha rgeable cell from the w atch, k eep ou t of the reach o f child ren to prevent acc idental swa llowing . If t he recha rgeable cell is accident ally s wallowed, consult a doctor i mmediatel y.
· Do n ot d isp ose of th e re cha rge able ce ll wit h o rdi nar y garba ge. Please fol low the ins truction s of your munic ipality regard ing collec tion of batte ries to prevent t he risk of fi re or environment al contamination.
WARNING
· Never us e a battery ot her than t he rechargea ble cell spe cified for use in t his watch. Alth ough the watch str ucture is design ed so th at it wi ll not operate when a nother ty pe of b attery is insta lled, if a si lver batter y or other t ype of ba ttery is i nstalle d in the wa tch and the wat ch i s re charg ed, ther e is the ris k of overc harg ing which ma y cause the bat tery to rupt ure. Th is can ca use da mag e to th e w atch an d i nju ry to t he wearer. When replacing the rechargeable cell, always make sure to us e the design ated recharg eable cell.
CAUTION
· Do not charge the wat ch at a h igh tempe rature (abo ut 60°C or hig her) as d oin g s o may caus e t he m ove ment to malfu nction.
Examples:
· C har gin g th e w atch to o cl ose to a li ght sou rce whi ch gener ates a lar ge amo unt of heat such as an i ncandes cent lamp or ha logen lamp.
* W hen charg ing u nder an incand escent lamp , be sure to
leav e 50c m or more bet ween the l amp and the watch to avoid exp osing the wat ch to excessive h eat.
· C harg ing the watc h in a locat ion where the temp erat ure may b ecome ex tremely h igh suc h as on the d ashboard of a vehicle.
Always keep your Watch Clean
Caring for your Watch
Handling of Rechargeable Cell
Use Only the Specified Battery
Recharging Precaut ions
using
Pulling out the
crown when
the
watch is wet
Warranty and Service
<Free Guarantee>
In the case a malfunction has occurred during the course of normal use while the wat ch is till under warranty, the watch will be repaired free of charge in accordance with the conditions of the warranty included with this manual.
<Stock Period of Repair Parts>
Our standard period for stocking repair parts for each model is generally seven ye ar. Whe n an exteri or part such as the watch case, glass, dial, hand, crown or band is damaged, a spare part with different appearance may sometimes be used.
<Repair Period>
Repairs can be performed on your watch within the repair parts stock period even after the fre e guarantee has expired. However, you will be charged for these repairs. Please take the watch to the shop where you purchased it and ask whether it can be repaired because the repair period varies according to the conditions of use, environment and so forth. Moreover, there are cases in which it is difficult to restore the watch to its original accuracy when decreased accurac y has resulted from long-term use.
< Change of Address or Receiving
as a Gift>
In the event that you have moved or have received you r watch as a gift, and are not able to bring your watch to the shop where it was purchased for serving, please consult Customer Support Center.
< Periodic Inspection
(Charge Basis)>
You should have your watch inspected ever y 2-3 years to extend its life and ensure safety. (charge basis) Wh en repl aci ng pa rts , alw ays mak e sure to request genuine parts. When it becomes necessary to replace packings and springs, it may sometimes als o be necessar y to inspect other parts or to make repairs in addition to replacing the parts. Please ask for more detailed information on repair or replacement expenses at the shop where you purchased your watch or Customer Support Center.
<Other Inquiries>
If you have any questions regarding the way warranty, repairs or other matters, please inquire at th e shop where you pu rch ased y our w atch or Cu sto mer Support Center.
Memo
Loading...