Functioning
The M602 transducer picks up seismically the absolute vibrations of
the machine by being fitted directly to the vibrating part.
Technical characteristics
Type of measurement : seismic (absolute vibrations)
Dynamic range : ± 50 g - 0.1 Hz ÷ 10.0 Khz (± 3 db)
Direction of vibrations : any
Sensitivity : 100 mV/g
Transverse sensitivity : ‹ 5%
Accuracy : 0,0003 g
Resonance frequency : › 25 Khz
Protection against shocks : ± 7000 g-pk
Power supply : 2 ÷ 20 mA - 18 ÷ 28 V
Outlet impedance : ‹ 100 ohm
Temperature range : - 48°C ÷ + 121°C
External casing material : 316-L stainless steel
Mounting screws : M8 x 1.25
Weight : 130 g
Protection against
external agents : CEI 70-1 standard, IP66 class
Connection : two wires shielded cable
Assembly
Make a threaded hole M8 x 1.25 the surface to be tested.
The surface where the transducer rests must be flat.
Maintenance
Zero.
Dimensions, fixture and connections drawings
as per front page drawing.
CEMB S.p.A.
23826 MANDELLO del LARIO
TEL. (+39) 0341.706111
www.cemb.com
e mail: stm@cemb.com
Div. Strumentazioni Via Risorgimento, 9
Fax (+39) 0341.706.299
Div. Garage Viale Costituzione, 28
Tel. (+39) 0341.700369
Fax (+39) 0341.700725
Training Center Viale Costituzione, 28
BB A L A N C I N G M A C H I NES