Passive Infrared Motion Detector with POPIT Interface ZX935Z
Installation Instructions
1.0Specifications
•Input Power: Connect to the Zonex Bus of the control panel.
•Current Draw: Less than 500 micro-amps. Two milli-amps when in walk test mode (LED on).
•Standby Power: There is no internal standby battery. Connect to DC power sources capable of supplying standby power if primary power fails. 500 micro-amp-hours required for each hour of standby time needed. Four hours minimum is required for UL Listed Requirements.
• Coverage: |
Standard Broad |
35 ft. x 35 ft. (10.7 m x 10.7 m) |
|
Barrier (Optional) |
35 ft. x 10 ft. (10.7 m x 3.1 m) |
|
Long Range (Optional) |
70 ft. x 10 ft. (21.4 m x 3.1 m) |
|
Pet (Optional) |
35 ft.x 35 ft. (10.7 m x 10.7 m) with 70 ft. (21.4 m) Long Range |
•Sensitivity: Standard or Intermediate.
•Tamper: A tamper condition is signaled through the Zonex Bus and displayed at the keypads when the cover is removed.
•Temperature: The storage and operating range is -20°F to +120°F (-29°C to +49°C). For UL Listed Requirements, the range is +32°F to +120°F (0°C to +49°C).
•Requirements: Compatible Bosch Security Systems control panel with POPEX module installed.
•Options: B335-3* Low Profile Swivel Mount Bracket, OMB93-3* Barrier Mirror, OMLR93-3* Long Range Mirror, and the OMP93-3*PetMirror.
*Shipped in packages of three.
Note: |
Misalignment of the detector when using an optional mounting bracket may reduce range. |
•Reading Bosch Security Systems, Inc. Product Date Codes: For Product Date Code information, refer to the Bosch Security Systems, Inc. Web site at: http://www.boschsecurity.com/datecodes/
2.0Programming
Program the address DIP switches as described for the control panel you are using.
Note: When installing the ZX935Z with a D7212B1, D8112, or D9112B1; place switch number “0” in the ON position.
Recommended point type programming: |
D8112 = 7571 |
|
D9112B1/D7212B1 = Point type 2, point response 2, no ring until restored. |
|
D9412/D9112 = Point type 2, point response E, no ring until restored. |
3.0 Mounting
Things to Avoid/Remember
Avoid
Direct hot and/or cold drafts. Windows. Small animals. Air conditioning outlets. Heat sources. Direct sunlight.
Remember
Won’t detect through glass. Best catch performance is across the pattern.
When using two or more detectors, cross patterns for best coverage.
ZX935Z
|
1. Select a location that is most likely to intercept an intruder moving across the coverage pattern. . |
Note: |
The recommended mounting height range is 6.5 ft. to 8.5 ft. (2 m to 2.6 m). The mounting surface should be solid and |
|
vibration free. |
|
|
|
0 1 2 3 4 5 6 |
+ |
+ |
– |
– |
T-Strip |
Address Switches |
30 Day |
Do Not Use |
4 Day |
These Pins |
OFF |
|
|
LED |
|
Tamper Switch |
Location of major items - Circuit Board
|
Wiring |
|
Knockouts |
Circuit Board |
|
Retainer Tabs (2) |
|
Bracket Mounting |
Mirror |
Hole |
Tracks (2) |
Surface |
|
Mounting |
Corner |
Holes (4) |
Mounting |
|
Holes (2) |
Rear Enclosure and Mounting Holes
2.Remove the cover. Insert a thin flathead screwdriver into the notch at the bottom of the cover and pry up.
3.Remove the circuit board/mirror unit from the enclosure. Push the board/mirror unit toward the top of the enclosure until it clears its four retainer tabs, then lift it out.
4.Open the knock-out wire entrance and route the wiring through.
3.1Surface or Corner Mounting
1.Open 2 holes for surface or corner mounting.
2.Mark the location for the mounting screws. Use the enclosure as a template. Pre-start the mounting screws.
3.Firmly mount the detector.
4.Replace the circuit board/mirror unit.
3.2Select the Vertical Angle
The angle adjust markings are on the mirror. Slide the mirror forward or back until the angle hash marks are in-line with the markers on each side of the frame.
This chart will help you set the correct Vertical Angle based on the mounting height, mirror type, and desired range.
Mounting |
Broad |
Barrier |
Long Range |
|||
Height |
20(6) |
35(10) |
20(6) |
35(10) |
40(12) |
70(20) |
6.5(2) |
-10° |
-6° |
-6° |
-4° |
-4° |
-2° |
|
|
|
|
|
|
|
7.5(2.3) |
-12° |
-8° |
-8° |
-6° |
-4° |
-2° |
|
|
|
|
|
|
|
8.5(2.6) |
-14° |
-10° |
-12° |
-8° |
-6° |
-4° |
|
|
|
|
|
|
|
Height and desired Range listed in feet (meters)
4.0Wiring
Only apply power after all connections have been made and inspected.
|
|
POPEX MODULE |
|
|
|
CAUTION |
• Connect wiring as shown to the right: |
+ |
|
|
|
|
|
|
|
||
|
+ |
|
|
|
|
|
|
|
|
|
|
|
|
– |
|
|
|
|
|
– |
|
|
|
|
|
1 |
2 |
3 |
4 |
|
|
+ |
+ |
- |
- |
IN OUT IN OUT
ZX935Z Installation Instructions
(+) |
|
ZONE EXPANSION |
(–) |
|
LOOP TO OTHER |
|
POINTS |
F01U069536-08 |
Page 2 |
© 2011 Bosch Security Systems, Inc. |