Intrusion Alarm Systems | D7212GV4 Control Panel
D7212GV4 Control Panel
www.boschsecurity.com
u Fully integrated intrusion and fire, allows users to
interface with one system instead of two
u Conettix IP‑based communication options provide
high‑speed, secure alarm transport and control
through connection of wired and/or cellular network
interfaces
GV4 panels are the premier commercial control panel
line from Bosch. GV4 panels integrate intrusion and
fire, providing one simple user interface for all
systems. With the ability to adapt to large and small
applications, the D7212GV4 provides up to 40
individually identified points that can be split into 4
areas. The control panel includes a communicator that
sends events to selected public switched telephone
network (PSTN), IP network, or cellular network
destinations through four programmable route groups.
With the D7212GV4 you can:
• Monitor alarm points for intruder or fire alarms while
operating keypads and other outputs
• Program all system functions local or remote using
Remote Programming Software (RPS) or by using
basic programming through the keypad user
interface.
Functions
Programmable Outputs
• 2 A alarm power at 12 VDC
• 1.4 A auxiliary power at 12 VDC
• Four alarm‑output patterns
• Programmable bell test
u Up to 4 programmable areas, each supporting both
perimeter and interior points
u 40 points with flexible configuration options to meet
multiple installation requirements
u Your choice of touch screen, vacuum florescent,
ATM style or LED keypads
System Response
• High-performance micro‑controller provides
industry‑leading system response
• High-speed device bus (NEW)
• 31 custom point indexes, including fire supervisory
• Selectable point response time
• Cross point capability
• Fire alarm verification
• Fire inspector’s local test
• Watch mode
• Scheduled events (SKEDs) arm, disarm, bypass and
unbypass points, control relays, and control authority
levels
User Interface
• Supervision of up to 8 keypads (up to 32
unsupervised keypads can be used)
• Remote Programming Software (RPS) Lite allows end
users to perform control panel management tasks –
Add/Delete/Change users and authorities, view, and
print the panel history event log
• Custom keypad text is fully programmable, including
remote programming
• Full function command menu including Custom
Functions
| D7212GV4 Control Panel
2
• Authority by area and 16‑character name for each
user
• 14 custom authority levels control user’s authority to
change, add, or delete passcodes; to disarm or
bypass points; and to start system tests
Area Configurations
Area programming offers a wide selection of different
system configurations. Each area is assigned an
account number to define annunciation, control, and
reporting functions. Multiple areas can be linked to a
shared area which is automatically controlled (hallway
or lobby). Area arming can be conditional on other
areas (master or associate). Any area can be
configured for perimeter and interior arming, not
requiring a separate area for this function.
Custom Functions
For added convenience, Custom Functions can be
programmed to eliminate keystrokes for users allowing
the installer to program an easy command for a
complicate function. For example, a custom function
can be written to bypass a group of points and arm
the system, allowing the user to perform this function
with one easy command. These Custom Functions can
be activated from a keypad, or automatically as a
scheduled event (SKED), providing further flexibility
and ease of use.
Passcode Security
For high security applications, GV4 can be configured
for several different passcode options.
• Two-Man Rule - Requires two people with two unique
passcodes to be present at the time of opening.
• Early Ambush - Allows users to verify that the facility
is safe by requiring two passcode entries at the same
keypad, sending a duress event if the user does not
enter the passcode a second time after inspecting the
premises.
Easy Exit Control
The D7212GV4 Control Panel changes from one armed
state to another armed state without disarming. For
example, if you change the state from Perimeter Arm
to Master Arm, the control panel complies and reports
the change. Easy Exit Control reduces the number of
keystrokes, simplifying system operation.
Programmable Passcode‑controlled Menu List
The system prompts users to enter a passcode prior to
viewing the keypad menu. The keypad display shows
the user the menu options allowed according to the
user’s authority level. Passcode-controlled menus
provide users only with the options and information
pertinent to them, simplifying system operation.
Flexible Control
The system provides the flexibility to select added
convenience or high security. For example, you can
restrict passcode arming and disarming to a keypad's
immediate local area, even if the user has access to
other areas. This is particularly useful for high security
areas, where a user may have access to the area, but
would prefer to only disarm the area individually rather
than with the rest of the system. Another option is to
program the system to disarm all areas the user can
access from any keypad.
Invisible Walk Test
A menu item allows the user to test invisible 24‑hour
points within the scope of the keypad without sending
a report to the central station.
System Users
The system supports up to 99 users, each can have a
passcode, and a wireless keyfob (NEW). User
passcodes contain three to six digits. Passcodes can
be assigned to one of 14 customized authority levels in
each area and can be restricted to operate only during
certain times.
Communication Formats
The D7212GV4 Control Panel prioritizes and sends
reports in Contact ID or Modem IIIa2 communications
formats to four route groups. Each group has a
programmable primary and backup destination.
The D7212GV4 provides flexible communications for
most central stations with reporting capabilities such
as:
• Individual point numbers
• Opening or closing reports by user and area number
• Remote programming attempts
• Diagnostic reports
IP Communication
The D7212GV4 uses the B420 Ethernet
Communication Module (NEW), DX4020 Ethernet
Communicator, and/or the ITS‑DX4020‑G Cellular
Communicator to communicate with the Conettix
D6600 and D6100i Communications Receiver/
Gateways. Using Conettix IP communication offers a
secure path that includes anti-replay/anti-substitution
features and provides enhanced security with
encryption. The B420, DX4020 and ITS‑DX4020‑G can
all be used for remote programming.
GV4 is the first Security Control panel to support DNS
(Domain Name System) for both remote programming
and central station communication. DNS provides ease
of use, eliminating the need to use static IP addresses
as your reporting destination, and accommodates a
simple solution for central station disaster recovery.
IP Setup is available via the installer keypad menus
and the remote programming software, eliminating the
need to use complicated internet programming tools
such as ARP and Telnet (NEW).
Communication Paths
D7212GV4 Control Panels accommodate up to four
separate destinations for primary, alternate, and
backup receivers for automatic test reports.
When resetting alarms or arming or disarming a
system, the user is identified by name and number.
3 | D7212GV4 Control Panel
Firmware Updates (NEW)
Remote firmware updates using the RPS Firmware
Update wizard through the IP connection (B420
Ethernet Communication Module) as well as an on-site
flash update key, provides for easy feature
enhancements without replacing ROM chips.
A wide variety of input options
Each point:
• Accommodates normally‑open (NO) and
normally‑closed (NC) devices with end‑of‑line (EOL)
resistor supervision.
• Is programmable for fire, fire supervisory, or intrusion
application.
• Can be hard-wired, addressable, or wireless.
Security and Fire Detection
The D7212GV4 Control Panel provides eight on‑board
points, and up to 32 additional off‑board points. You
can program individual points to monitor all types of
burglar alarms, fire alarms, and supervision devices.
Wireless Interface (New)
The B820 SDI2 Inovonics Interface Module connects
an Inovonics EN4200 Serial Receiver to the control
panel SDI2 bus, allowing this UL Listed (NEW)
wireless system to be programmed locally via the
panel keypad, as well as remotely through RPS.
Event Log
The event log stores up to 1,000 local and transmitted
events. The event log includes time, date, event, area,
point, user number, and transmission status (NEW).
View the event log from a keypad or use RPS to
remotely retrieve event information. RPS operators
can retrieve events periodically using one call, rather
than receiving several calls each day. When the event
log reaches a programmed threshold of stored events,
it can send an optional report to a receiver.
Scheduled Events (SKEDs)
The internal clock and calendar start individually
scheduled events (SKEDs). SKEDs perform functions
such as arm or disarm, relay control, or point
bypassing. The D7212GV4 Control Panel offers:
• 40 scheduled events with up to 25 different functions
• Eight opening windows and eight closing windows
• Eight user windows
• Day-of-week, date-of-month, or holiday only schedules
• Four holiday schedules of 366 days each (leap year)
Fire Test
When a user activates Fire Test Mode, the control
panel suppresses all reports to the central station. The
keypad and annunciator show all testing data. An
automatic sensor reset feature saves time; you do not
need to reset the sensors manually. At the end of test,
the keypad shows the number of untested points.
Programming, Diagnostics and Controls
Installers can program locally or remotely through RPS
as well as basic keypad programming. A programmable
system passcode prevents unauthorized remote
programming.
Two Data Buses (NEW)
GV4 provides 2 data buses which support a wide array
of components. The SDI bus supports keypads access
and communications modules and also allows
connection of existing components in a retrofit
application. The SDI2 bus (NEW) supports new input
and output devices, as well as a new wireless interface
module, and an Ethernet communicator. SDI2 allows
these devices to be mounted up to 1000 ft (305 m)
from the control panel, providing installation
convenience and flexibility.
Certifications and approvals
USA:
UL 365 Police Station Connected Burglar Alarm Units
and Systems
UL 609 Local Burglar Alarm Units and Systems
UL 636 Holdup Alarm Units and Systems
UL 985 Household Fire Warning System Units
UL 1023 Household Burglar Alarm System Units
UL 1076 Proprietary Burglar Alarm Units and Systems
UL 1610 Central Station Burglar Alarm Units
ANSI/SIA
CP-01:2010
CSFM California Office of The State Fire Marshall
FCC Part 15 Class B
Region Certification
USA UL AMCX.S1871 Central-station Alarm
Canada ULC AMCX7.S1871 - Central Station Alarm
False Alarm Reduction
Units
UL AMTB.S1871 Control Panels, SIA False
Alarm Reduction
UL ANET.S1871 Holdup Alarm Units
UL AOTX.S1871 Local Alarm Units
UL APAW.S1871 Police-station-connected
Alarm Units
UL APOU.S1871 Proprietary Alarm Units
UL NBSX.S1871 Household Burglar Alarm
System Units
UL UTOU.S1871 Control Units and Acces-
sories, Household System Type
CSFM see our website
Units Certified for Canada
ULC APOU7.S1871 Proprietary Alarm Units
Certified for Canada
ULC APAW7.S1871 Police-station-connec-
ted Alarm Units Certified for Canada