Bosch AMAX panel 2000, AMAX panel 2000 EN User Manual

AMAX panel 2000 / AMAX panel 2000 EN
F.01U.249.500
en User Guide
AMAX panel 2000 / AMAX panel 2000 EN Table of Contents | en 3
Robert Bosch Engineering and Business Solutions Limited User Guide F.01U.249.500 | V2 | 2011.11
Table of Contents
2.2.2 Disarming with wireless control Key 9
3 Faults or Tamper conditions 10
3.1 System fault or tamper analysis Mode 10
4 Walk test mode 12
5 Event Memory Recall mode 13
6 Reset the Control Panel 14
7 Bypassing 15
7.1 Bypassing Zones 15
7.2 Bypassing Faults and Tamper conditions (Except Zone Tampers) 15
8 Enable / Disable the installers code 16
9 Change individual code 17
10 Keypad alarm operation commands 18
10.1 Duress alarm 18
10.2 Keypad panic alarm 18
10.3 Keypad fire alarm 18
10.4 Keypad medical alarm 18
11 Domestic Dialing 19
Glossary 20
Index 21
4 en | Introduction AMAX panel 2000 / AMAX panel 2000 EN
F.01U.249.500 | V2 | 2011.11 User Guide Robert Bosch Engineering and Business Solutions Limited
1 Introduction
Quick keypad operation instructions
Table 1.1 Quick keypad operation instructions
ICP-AMAX - LED8-8 Zone LED Keypad ICP-AMAX-LCD8 - 8 Zone LCD Keypad
Arming
AWAY arm [code] + [#] / [#] (quick arming) STAY arm [code] + [*] / [*] (quick arming)
Disarming
Disarm [code] + [#]
Other Commands
Fault and Tamper Analysis
[code] + [2] [#]
Walk test [code] + [4] [#] Event recall [code] + [5] [#] System Reset [code] + [6] [#] Bypassing zones [code] + [9] [#] [zone] + [*] [#] Bypassing Faults
and Tamper conditions
[code] + [97] [#]
Enable/Disable Installer code
Enable = [code] + [98] [#] Disable = [code] + [98] [*]
Change individual code
[code] + [99] [#] [newcode] [#]
Alarm Commands
Duress alarm [code] + [0] [#] Emergency
alarm
Simultaneously press and hold [1] and [3] or [*] and [#]
Fire alarm Simultaneously press and hold [4] and [6] Medical alarm Simultaneously press and hold [7] and [9] Default user code = 2580
AMAX panel 2000 / AMAX panel 2000 EN Introduction | en 5
Robert Bosch Engineering and Business Solutions Limited User Guide F.01U.249.500 | V2 | 2011.11
Keypad Indicators
Table 1.2 Keypad Indicators
LCD keypad indicator icons
LED keypad indicator lights
Status Definition
Zone (1-8) on Zone is triggered.
off Zone is normal. Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Zone was alarmed or is in alarm status.
Slow flash (1 second lights on/1 second lights off)
Zone is manually bypassed or interior Zone is in STAY ARM mode.
AWAY on System is armed in AWAY mode.
off System not armed in AWAY mode. Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code function mode. STAY indicator flashes simultaneously.
STAY on System is armed in STAY mode.
off System not armed in STAY mode. Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code function mode. AWAY indicator flashes simultaneously. When bypass function is performed, the STAY indicator only flashes.
MAINS on AC main power is normal.
Slow flash (1 second lights on/1 second lights off)
AC main power supply failed.
FAULTS on System fault or Tamper condition
is present. off System is in normal status. Flashes System fault or Tamper condition
must be acknowledged. on System is disarmed.
1 2 3 ….
6 en | Introduction AMAX panel 2000 / AMAX panel 2000 EN
F.01U.249.500 | V2 | 2011.11 User Guide Robert Bosch Engineering and Business Solutions Limited
Keypad sounds
Table 1.3 Keypad sounds
Sound indicator Definition
One short beep A keypad button has been pressed. One single one-
second beep
The requested operation is refused. Incorrect operation signal.
Two short beeps The system accepted the code. The system executed the requested
function.
One short beep per second
In walk test mode.
One short beep every two seconds
Exit time started.
Continued sound
Last 10s on exit time – Keypad fault/tamper sound (fault/tamper to be acknowledged) – Keypad alarm sound
Continuous 0.5 second beep, stops 0.5 seconds
Entry delay time (until alarm ends or system is disarmed).
AMAX panel 2000 / AMAX panel 2000 EN Introduction | en 7
Robert Bosch Engineering and Business Solutions Limited User Guide F.01U.249.500 | V2 | 2011.11
Zone description
Zone 1 ______________________________________________________ Zone 2 ______________________________________________________ Zone 3 ______________________________________________________ Zone 4 ______________________________________________________ Zone 5 ______________________________________________________ Zone 6 ______________________________________________________ Zone 7 ______________________________________________________ Zone 8 ______________________________________________________ Exit Time ___________________________________________________ sec Entry Time _________________________________________________ sec
User Code Names
Code 1 _____________________________________________________ Code 2 _____________________________________________________ Code 3 _____________________________________________________ Code 4 _____________________________________________________ Code 5 _____________________________________________________ Code 6 _____________________________________________________ Code 7 _____________________________________________________ Code 8 _____________________________________________________ Code 9 _______________________________________________________Keyfob 1 Code 10 _____________________________________________________ Keyfob 2 Code 11 _____________________________________________________ Keyfob 3 Code 12 _____________________________________________________ Keyfob 4 Code 13 _____________________________________________________ Keyfob 5 Code 14 _____________________________________________________ Keyfob 6 Code 15 _____________________________________________________ Keyfob 7 Code 16 _____________________________________________________ Keyfob 8
8 en | Arming and Disarming the System AMAX panel 2000 / AMAX panel 2000 EN
F.01U.249.500 | V2 | 2011.11 User Guide Robert Bosch Engineering and Business Solutions Limited
2 Arming and Disarming the System
2.1 Arming the System
2.1.1 Arming in AWAY mode
Arming the system in AWAY Mode is normally performed when you leave the premises and require that all zones are activated in a ready state to detect an intrusion.
2.1.1.1 Keypad arming
The system can be set to AWAY mode in two different ways.
To arm the System in AWAY mode (method 1)
Enter your code and press [#]. Two beeps sound, the AWAY indicator flashes slow, and exit time starts. After exit time, the AWAY indicator turns is lit.
To arm the System in AWAY mode (method 2)
Press and hold [#] until it beeps twice. The AWAY indicator flashes slow, and exit time starts. After exit time, the AWAY indicator is lit. Please contact your installer to enable/disable this function.
2.1.1.2 Telephone remote arming
The user dials the control panel number. The control panel answers the call and issues a long beep. After the long beep, the user must press the [#] key. When the Panel receives the signal it will confirm the arming of the control panel with a high tone. Please contact your installer to enable/disable this function.
2.1.1.3 Arming in AWAY mode with wireless remote control Key
Press and hold the Arming Button until two beeps sound on the remote keypad and the AWAY indicator flashes slow. Exit time starts. After exit time, the AWAY indicator is lit.
NOTICE!
When the number of incorrect code entries on the keypad reaches a specified number, the keypad will automatically lock for 180 seconds and alarm is reported.If the keypad is idle for 4 minutes, the system will automatically exit from any operational mode.
RE012E:2 standard wireless remote control key
1 –Button 1: Arm in AWAY mode 2 –Button 2: Disarm 3 –Button 1 and 2: Press both buttons at the same time to activate Panic alarm
1
2
3