Bosch AMAX 2100, AMAX 3000, AMAX 4000 User Manual

AMAX
2100 / 3000 / 4000
en User Guide
1
Safety 5
2
Short information 6
2.1 Introduction 6
2.2 Keypads 7
2.3 Keypad Indicators 8
2.4 Quick Keypad Operations Instructions 10
2.5 User Menu 13
3
Arming and Disarming the System 14
3.1 Arming the System 14
3.1.1 Arming in AWAY Mode 14
3.1.2 Arming in STAY Mode 15
3.1.3 Forced Arming 15
3.1.4 Arming with a Master Keypad 16
3.2 Disarming the System 17
3.2.1 Disarming with Code 17
3.2.2 Disarming with Key Switch 17
3.2.3 Disarming with RADION RF Keyfob 17
3.2.4 Disarming with a Master Keypad 17
4
Changing the Menu Language 18
5
System Test 19
5.1 Siren Test 19
5.2 Communication Test 19
5.3 Walk Test Mode 19
6
Bypassing 20
6.1 Bypassing/Unbypassing Zones 20
6.1.1 How to Bypass/Unbypass a Zone via Text Keypad 20
6.1.2 How to Bypass/Unbypass a Zone via LED/LCD Keypad 20
6.2 Bypassing Faults or Tamper Conditions 20
7
Schedules 21
8
Macros 22
8.1 Recording Macros 22
8.2 Playing Macros 23
9
Codes 24
9.1 Add/Change User Codes 24
9.2 Change Individual Code 25
10
Keypad Alarm Operation Commands 26
10.1 Keypad Panic Alarm 26
10.2 Keypad Fire Alarm 26
10.3 Keypad Medical Alarm 26
11
Domestic Dialing 27
11.1 Domestic Dialing Alarm 27
11.2 Confirming the Domestic Call 27
12
Event Log Recall Mode 28
12.1 How to Select All Event Log Recall Mode 28
12.2 How to Select EN Event Log Recall Mode 28
12.3 How to Select Dialer Event Log Recall Mode 28
AMAX Table of Contents | en 3
Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569
13
Faults and Tamper Conditions 29
13.1 System Fault or Tamper Analysis Mode via Text Keypad 29
13.2 System Fault or Tamper Analysis Mode via LED/LCD Keypad 29
14
Resetting the Control Panel 33
15
Troubleshooting 34
4 en | Table of Contents AMAX
2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH
Safety
Danger!
Electricity Injuries due to electricity are possible if the system is not operated correctly or if the system is opened or modified.
Never open or modify the system. – Please contact your installer if you want to get your system modified.
!
Caution!
Sensitive components Damage of sensitive components is possible if the system is not handled carefully or if the system is opened or modified.
Always handle the system carefully. – Never open or modify the system. –
Please contact your installer if you want to get your system modified.
1
AMAX Safety | en 5
Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569
Short information
Introduction
This User Guide contains information on how to operate the system easily and quickly. The guide describes the main steps required for operation of the AMAX panel 2100/3000/4000 together with a text and/or a LED/LCD keypad described in Keypads, page 7. It is possible to add an optional text keypad as a master keypad. Detailed information about the installation of this and other modules and devices, advanced settings and programming can be found in the Installation Guide. Information on the main steps required for basic system installation and setup can be found in the Quick Start Guide.
2
2.1
6 en | Short information AMAX
2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH
Keypads
The following text keypad can be used for operating AMAX panel 2100/3000/4000.
IUI-AMAX4-TEXT
The following LED/LCD keypads can be used for operating AMAX panel 2100/3000/4000.
IUI-AMAX3-LED8 IUI-AMAX3-LED16
IUI-AMAX-LED8 IUI-AMAX-LCD8
Notice!
Only a text keypad can be used as a master keypad.
2.2
AMAX Short information | en 7
Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569
Keypad Indicators
The following table shows an overview and a description of the keypad indicator icons.
Keypad Indicator Icons
Status Definition
1 2 3 ….
ZONE (1-8)
on Zone is triggered.
off Zone is normal.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Zone was alarmed or is in alarm status.
Slow flash (1 second lights on/1 second lights off)
Zone is manually bypassed or interior Zone is in STAY arm mode.
AWAY
on System is armed in AWAY mode.
off System not armed in AWAY mode.
Slow flash (1 second lights on/1 second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or code function mode. STAY indicator flashes simultaneously.
STAY
on System is armed in STAY mode.
off System not armed in STAY mode.
Slow flash (1 second lights on/1 second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or code function mode. AWAY indicator flashes simultaneously. When bypass function is performed, only the STAY indicator flashes.
MAINS
on AC main power is normal.
Slow flash (1 second lights on/1 second lights off)
AC main power supply failed.
FAULTS
on System fault or Tamper condition
is present.
off System is in normal status.
Flashes System fault or tamper condition
must be acknowledged.
on System is disarmed.
2.3
8 en | Short information AMAX
2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH
The following table shows an overview and a description of the keypad sound icons.
Sound Indicator Definition
Short beep A keypad button has been pressed.
Short beep, followed by a one-second beep
The requested operation is refused. Incorrect operation signal.
Two short beeps The system accepted the code. The system executed
the requested function.
One short beep every minute Fault tone, unacknowledged system failure.
One short beep every two seconds Exit time started.
Continued sound Last 10 seconds on exit time
Keypad fault or tamper sound (fault or tamper to be acknowledged)
Keypad alarm sound
Continuous 0.5 second beep, stops for 0.5 seconds
Entry delay time (until alarm ends or system is
disarmed)
Exit delay time (stops 10 seconds before exit
delay stops)
AMAX Short information | en 9
Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569
Quick Keypad Operations Instructions
The following table shows an overview of the quick keypad operations and the corresponding user permissions. For information on changing codes and defining user permission levels, please refer to Codes, page 24.
Function Command
Default User Code = 2580
D A B S M1M2I
N
Arm/Disarm
AWAY Arm [code] + [#] / [#] for 3 sec. (quick arm) √ √ √ √ √ √ √
AWAY Arm All Areas (only on master keypad)
[code] + [0] [0] + [#] √ √ √ √ √ √ √
Direct AWAY Arm (only on master keypad
[code] + [2-digit area no.] + [#] √ √ √
STAY Arm [code] + [*] / [*] for 3 sec. (quick arm) √ √ √ √ √ √ √
STAY Arm All Areas (only on master keypad)
[code] + [0] [0] + [*] √ √ √ √ √ √ √
Direct STAY Arm (only on master keypad
[code] + [2-digit area no.] + [*] √ √ √
Disarm [code] + [#] √ √ √ √ √
Disarm All Areas (only on master keypad)
[code] + [#] √ √ √ √ √
Display
Display Info (Fault/Tamper Analysis)
[code] + [2] [1] + [#] √ √ √
Bypass
Bypass/Unbypass Zone [code] + [3] [1] + [#] + [2-digit zone no.]
+ [#]
√ √ √ √ √
Bypass Fault/Tamper [code] + [3] [4] + [#] √ √ √
Reset
Reset Fault/Tamper (In some country versions only the installer can reset a tamper alarm)
[code] + [6] + [#] √ √ √
Macros
Record Macro 1 [code] + [8] [1] + [#] + operation + [#]
for 3 sec.
√ √ √ √
2.4
10 en | Short information AMAX
2014.09 | 03 | F.01U.295.569 User Guide Bosch Sicherheitsysteme GmbH
Record Macro 2 [code] + [8] [2] + [#] + operation + [#]
for 3 sec.
√ √ √ √
Record Macro 3 [code] + [8] [3] + [#] + operation + [#]
for 3 sec.
√ √ √ √
Play Macro 1 [code] + long press [1] / [1] for 3 sec.
(quick macro)
* * * * * *
Play Macro 2 [code] + long press [2] / [2] for 3 sec.
(quick macro)
* * * * * *
Play Macro 3 [code] + long press [3] / [3] for 3 sec.
(quick macro)
* * * * * *
Alarm commands
Keypad Emergency Alarm long press [1] and [3] or [*] and [#] √ √
Keypad Fire long press [4] and [6] √ √
Keypad Medical Alarm long press [7] and [9] √ √
Other Commands
Switch to Master Keypad [code] + [0] [0] [0] + [#] (only on text
keypad)
√ √ √ √
Switch to Area 01-16 [code] + [0] [2-digit area no.] + [#] (only
on text keypad)
√ √ √ √
Display all Event Log [code] + [2] [2] + [#] (only on text
keypad)
Display EN Event Log [code] + [2] [3] + [#] (only on text
keypad)
Display Dialer Event Log [code] + [2] [4] + [#] (only on text
keypad)
Siren Test [code] + [4] [1] + [#] √ √ √
Communication Test [code] + [4] [2] + [#] √ √ √
Walk Test [code] + [4] [3] + [#] √ √ √
Daylight Saving Time (+1h) [code] + [5] [2] + [#] √ √ √
Daylight Saving Time (-1h) [code] + [5] [3] + [#] √ √ √
Add/Change User Code [code] + [5] [4] + [#] √ √ √
Change Individual Code [code] + [5] [5] + [#] √ √ √
Call Back [code] + [5] [7] + [#] √ √ √
Change Language [code] + [5] [8] + [#] + [2-digit no. for
available languages] + [#] 01=EN; 02=DE; 03=ES; 04=FR ; 05=PT; 06=PL; 07=NL; 08=SE
√ √ √
AMAX Short information | en 11
Bosch Sicherheitsysteme GmbH User Guide 2014.09 | 03 | F.01U.295.569
Loading...
+ 25 hidden pages