Behringer XENYX QX1002USB User Manual [ru]

0 (0)
User Manual
XENYX
QX1202 /QX1002
Premium 12/10-Input 2-Bus Mixer with XENYX Mic Preamps
& Compressors, British EQs, KLARK TEKNIK Multi-FX Processor
andUSB/Audio Interface
CLIP
SIG

Thank you

Congratulations! In purchasing our XENYX QX1202USB/QX1002USB you have
acquired a mixing console whose small size belies its incredible versatility and
audioperformance.
The BEHRINGER XENYX mixing console oers you premium-quality microphone
preampliers with optional phantom power supply, balanced line inputs and
the ability to connec t external eects processors. Because of its extensive and
carefully thought-out routing possibilities, your XENYX lends itself equally to
both live and studio use.
Table of Contents
Thank you .......................................................................2
Important Safety Instructions ...................................... 3
Legal Disclaimer ............................................................. 3
Limited warranty ............................................................ 3
1. Introduction ............................................................... 4
1.1 General mixing console functions ............................... 4
1.2 Before you get started ...................................................... 5
1.2.1 Shipment ......................................................................... 5
1.2.2 Initial operation ............................................................. 5
1.2.3 Online registration ....................................................... 5
2. Control Elements and Connectors .......................... 5
2.1 Mono channels .................................................................... 5
2.2 Stereo channels ................................................................... 6
2.3 Connector array of the main section ........................... 7
2.4 Main section ......................................................................... 7
2.5 USB Connector .................................................................... 8
2.6 Digital eects processor .................................................. 8
3. Applications ............................................................. 10
3.1 Recording studio ...............................................................10
3.2 Live sound ........................................................................... 11
4. Installation ............................................................... 11
4.1 Mains connection ............................................................. 11
4.2 Audio connections ........................................................... 12
5. Specications .......................................................... 13
Important Safety
Instructions

LEGAL DISCLAIMER

LIMITED WARRANTY

Terminals marked with this symbol carry
electrical current of su cient magnitude
to constitute risk of electric shock.
Use only high-quality professional speaker cables with
¼" TS or twist-locking plugs pre-installed. Allother
installation or modi cation should be performed only
by quali edpersonnel.
This symbol, wherever it appears,
alertsyou to the presence of uninsulated
dangerous voltage inside the
enclosure-voltage that may be su cient to constitute a
risk ofshock.
This symbol, wherever it appears,
alertsyou to important operating and
maintenance instructions in the
accompanying literature. Please read the manual.
Caution
To reduce the risk of electric shock, donot
remove the top cover (or the rear section).
No user serviceable parts inside. Refer servicing to
quali ed personnel.
Caution
To reduce the risk of  re or electric shock,
do not expose this appliance to rain and
moisture. The apparatus shall not be exposed to dripping
or splashing liquids and no objects  lled with liquids,
suchas vases, shall be placed on the apparatus.
Caution
These service instructions are for use
by quali ed service personnel only.
Toreduce the risk of electric shock do not perform any
servicing other than that contained in the operation
instructions. Repairs have to be performed by quali ed
servicepersonnel.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as
radiators, heat registers, stoves, or other apparatus
(including ampli ers) that produce heat.
9. Do not defeat the safety purpose of the polarized
or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding-type plug
has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. Ifthe
provided plug does not  t into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles,
and the point where they exit from the apparatus.
11. Use only attachments/accessories speci ed by
themanufacturer.
12. Use only with the
cart, stand, tripod, bracket,
or table speci ed by the
manufacturer, orsold with
the apparatus. When a cart
is used, use caution when
moving the cart/apparatus
combination to avoid
injury from tip-over.
13. Unplug this apparatus during lightning storms or
when unused for long periods of time.
14. Refer all servicing to quali ed ser vice personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power supply cord or plug
is damaged, liquid has been spilled or objects have fallen
into the apparatus, the apparatus has been exposed
to rain or moisture, does not operate normally, or has
beendropped.
15. The apparatus shall be connected to a MAINS socket
outlet with a protective earthing connection.
16. Where the MAINS plug or an appliance coupler is
used as the disconnect device, the disconnect device shall
remain readily operable.
TECHNICAL SPECIFICATIONS AND APPEARANCES
ARE SUBJECT TO CHANGE WITHOUT NOTICE AND
ACCURACY IS NOT GUARANTEED. BEHRINGER,
KLARKTEKNIK, MIDAS, BUGERA, AND TURBOSOUND
ARE PART OF THE MUSIC GROUP MUSICGROUP.COM.
ALL TRADEMARKS ARE THE PROPERTY OF THEIR
RESPECTIVE OWNERS. MUSICGROUP ACCEPTS NO
LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED
BY ANY PERSON WHO RELIES EITHER WHOLLY OR
IN PART UPON ANY DESCRIPTION, PHOTOGRAPH
OR STATEMENT CONTAINED HEREIN. COLORS AND
SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT.
MUSIC GROUP PRODUCTS ARE SOLD THROUGH
AUTHORIZED FULLFILLERS AND RESELLERS ONLY.
FULLFILLERSAND RESELLERS ARE NOT AGENTS OF
MUSICGROUP AND HAVE ABSOLUTELY NO AUTHORITY
TO BIND MUSICGROUP BY ANY EXPRESS OR IMPLIED
UNDERTAKING OR REPRESENTATION. THIS MANUAL
IS COPYRIGHTED. NO PART OF THIS MANUAL MAY
BE REPRODUCED OR TRANSMITTED IN ANY FORM
OR BY ANY MEANS, ELECTRONIC OR MECHANICAL,
INCLUDING PHOTOCOPYING AND RECORDING OF ANY
KIND, FOR ANY PURPOSE, WITHOUT THE EXPRESS
WRITTEN PERMISSION OF MUSICGROUPIPLTD.
ALL RIGHTS RESERVED.
© 2013 MUSICGroupIPLtd.
Trident Chambers, Wickhams Cay, P.O. Box 146,
Road Town, Tor tola, British Virgin Islands
For the applicable warranty terms and conditions
and additional information regarding MUSIC Group’s
Limited Warranty, please see complete details online at
www.music-group.com/warranty.

1. Introduction

The XENYX Series represents a milestone in the development of mixing console
technology. With the new XENYX microphone preamps including phantom power
as an option, balanced line inputs and a powerful eects section, themixing
consoles in the XENYX Series are optimally equipped for live and studio
applications. Owing to state-of-the-art circuitry your XENYX console produces
a warm analog sound that is unrivalled. With the addition of the latest digital
technology these best-in-class consoles combine the advantages of both analog
and digital technology.
The microphone channels feature high-end XENYX Mic Preamps that compare
well with costly outboard preamps in terms of sound quality and dynamics and
boast the following features:
• 130 dB dynamic range for an incredible amount of headroom
• A bandwidth ranging from below 10 Hz to over 200 kHz for crystal-clear
reproduction of even the nest nuances
• The extremely low-noise and distortion-free circuitry guarantees absolutely
natural and transparent signal reproduction
• They are perfectly matched to every conceivable microphone with up to
60dB gain and +48 volt phantom power supply
• They enable you to use the greatly extended dynamic range of your
24-bit/192-kHz HD recorder to the fullest, thereby maintaining optimal
audioquality
“British EQ”
The equalizers used for the XENYX Series are based on the legendary circuitry of
top-notch consoles made in Britain, which are renowned throughout the world
for their incredibly warm and musical sound character. Even with extreme gain
settings these equalizers ensure outstanding audio properties.
KLARK TEKNIK FX Processor
Additionally, your XENYX mixing console has a KLARK TEKNIK eects processor
with 24-bit A/D and D/A converters included, which gives you 100 presets
producing rst-class reverb, delay and modulation eects plus numerous
multi-eec ts in excellent audio quality.
Caution!
We should like to draw your attention to the fac t that extreme volumes
may damage your hearing and/or your headphones or loudspeakers.
Turn the MAIN MIX control and PHONES control in the main section fully
counterclockwise before you switch on the unit. Always be careful to
set appropriate volume levels.

1.1 General mixing console functions

A mixing console fulls three main functions:
• Signal processing:
Preamplication
Microphones convert sound waves into voltage that has to be amplied
several-fold; then, this voltage is turned into sound that is reproduced
in a loudspeaker. Because micro phone capsules are very delicate in their
construction, output voltage is very low and therefore susceptible to
interference. Therefore, mic signal voltage is amplied directly at the mixer
input to a higher signal level that is less prone to interference. This higher,
interference-safe signal level has to be achieved through amplication using
an amplier of the highest quality in order to amplify the signal and add
as little noise to it as possible. The XENYX Mic Preamp performs this role
beautifully, leaving no traces of noise or sound coloration. Interferencethat
could take place at the preamplication level could aect signal quality
and purity, and would then be passed on to all other devices, resulting in
inaccurate sounding program during recording or playback.
Level-setting
Signals fed into the mixer using a DI-box (Direct Injection) or the output of a
sound card or a keyboard, often have to be adjusted to the operating level of
your mixing console.
Frequency response correction
Using the equalizers found in each channel strip, you can simply, quickly and
eectively adjust the way a signal sounds.
• Signal distribution:
Individual, processed signals from the channel strips are compiled on
busses and are fed into the main section for fur ther processing. Connections
for recording equipment, power ampliers, headphones as well as RCA
connectors are available here. The mix is sent to the internal FX processors or
external eects processors via aux sends and returns. Similarly, a mix can be
created for the musicians on the stage (monitor mix).
• Mix:
All other mixing console functions fall under this vital category. Creating a
mix means primarily adjusting the volume levels of individual instruments
and voices to one another as well as giving them the appropriate weight
within the overall frequency spectrum. Likewise, you’ll have to sensibly
spread individual voices across the stereo image of a signal. At the end of
this process, adjusting the level of the entire mix to other equipment in the
signal path is required (e. g. recorder/crossover/amplier).
The interface of BEHRINGER mixing consoles is optimized for these tasks,
enabling you to easily keep track of the signal path.

1.2 Before you get started

1.2.1 Shipment

Your mixing console was carefully packed in the factory to guarantee safe
transport. Nevertheless, we recommend that you carefully examine the
packaging and its contents for any signs of physical damage that may have
occurred during transit.
If the unit is damaged, please do NOT return it to us, but notify your
dealer and the shipping company immediately, otherwise claims for
damage or replacement may not be granted.
To assure optimal protection of your XENYX during use or transport,
we recommend utilizing a carrying case.
Please always use the original packaging to avoid damage due to
storage or shipping.
Never let unsupervised children play with the XENYX or with
its packaging.
Please dispose of all packaging materials in an environmentally-
friendly fashion.

1.2.2 Initial operation

Be sure that there is enough space around the unit for cooling purposes and to
avoid overheating please do not place your mixing console on high-temperature
equipment such as radiators or power amps.
Never connect the XENYX to the power supply unit when the latter is
connected to the mains! First connect the power supply unit to the
console, then connect the power supply unit to the mains.
Please make sure that all units have a proper ground connection.
For your own safety, never remove or disable the ground
conductor from the unit or on the AC power cord. The unit should
always be connected to a mains socket outlet with a protective
earthing connection.
When installing the product, ensure the appliance coupler or power
cord is easily accessible for disconnecting the unit from mains.

1.2 .3 Online registration

Please register your new BEHRINGER equipment right after your purchase
by visiting http://behringer.com and read the terms and conditions of our
warrantycarefully.
Should your BEHRINGER product malfunction, it is our intention to have it
repaired as quickly as possible. To arrange for warranty service, please contact
the BEHRINGER retailer from whom the equipment was purchased. Shouldyour
BEHRINGER dealer not be located in your vicinity, you may directly contact
one of our subsidiaries. Corresponding contact information is included in the
original equipment packaging (Global Contact Information/European Contact
Information). Should your country not be listed, please contact the distributor
nearest you. A list of distributors can be found in the support area of our
website(http://behringer.com).
Registering your purchase and equipment with us helps us process your repair
claims more quickly and eciently.
Thank you for your cooperation!

2. Control Elements and Connectors

This chapter describes the various control elements of your mixing console.
Allcontrols, switches and connectors will be discussed in detail.

2.1 Mono channels

Fig. 2.1: Connector s and controls on the mo nochannels
MIC
Each mono input channel oers a balanced microphone input via the XLR
connector and also features switchable +48 V phantom power supply for
condenser microphones. The XENYX preamps provide undistorted and noise-free
gain as is typically known only from costly outboard preamps.
Please mute your playback system before you activate the phantom
power supply to prevent switch-on thumps being directed to
your loudspeakers. Please also note the instructions in chapter
2.4 “Main section.
LINE IN
Each mono input also features a balanced line input on a ¼"connector.
Unbalanced devices (mono connectors) canalso be connected to these inputs.
Please remember that you can only use either the microphone
or the line input of a channel at any one time. You can never use
both simultaneously!
Loading...
+ 10 hidden pages